General information

The 4451 Chronothermostat is a flush-mounting device that can be used for heating and air-conditioning systems; it is possible – through several programming possibilities – to adjust the temperature at any time of the day and in a differentiated manner, every day of the week. It is possible to choose how to use a standard program (already stored but can be changed according to the specific needs of the user) or to create a new one with a simple programming procedure.
A large back-lit display shows you at all times the program setting, the status of the system, and the temperature of the room.
The Chronothermostat consists of a base used for the system’s electric connections and a removable front part to allow the user to execute the programming operations and to replace the batteries more easily.

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.1

The front side

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.2

  1. Graphic display: displays the messages which determine the programming operations as well as the system status
  2. Selection Keys: these let you cycle through the functioning modes inside the menu, if any, while the main screen is being viewed;
  3. OK Key: accesses the main menu, confirms the selection displayed or the data entered
  4. Sensor: measures the ambient temperature
  5. C Key: cancels the selection and returns to the previous page; if held down, it returns to the initial page
  6. Scroll Keys: these let you change the set temperature while the main screen is being viewed; when inside the menu, you can scroll the list of the options available.

The display

During normal operation, the graphic display shows the following background information:bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.3

Symbols
Depending on the functioning mode selected, the display may be characterised by the following symbols:

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.4

Weekly
Temperature profile and number of the operational program
The range of the corresponding time will flash on the graph (for example, 11:26 will flash on the square corresponding to the time from 11:00 to 12:00).

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.5Manual
Manual mode Icon (hand)

Holidays
Antifreeze or Thermal protection Icon, time and date of Holidays program end

Timed
Manual mode Icon and number of hours and minutes to the end of the Timed program

Antifreeze
Antifreeze (winter) or Thermal protection (summer) mode Icon

OFF
OFF mode Icon

If an external probe is connected to the Chronothermostat and the preset function is “External Temp.”, its associated icon will be shown on the display. Every 2 seconds the outside temperature and the ambient temperature will be displayed alternately (in the same position). (See chapter 2.1.12).

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.6External probe
External temperature signaling Icon
When the battery is flat, its signaling icon will be displayed (in any mode, even when the screen saver is functioning). If flashing, the device will not work, thus the batteries need to be replaced.
bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.7Battery
Flat battery signaling Icon

Your Chronothermostat: use it now!

First activation

To enable the Chronothermostat:

Daylight saving time: if the default setup is kept, “Manual” must be updated manually; to set up the “Automatic” update mode, see paragraph “Set Daylight saving time” on see chapter 2.1.4).

Introduction and standard functions

Navigation keys

When the main screen is displayed, the following operations can be executed with the navigation keys:

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.10

View the functioning modes

When the Chronothermostat display shows the Screen saver (or when it is off), the preset functioning mode will be displayed if any key is pressed.

Scroll the modes

When the Chronothermostat display shows the Screen saver (or when it is off), the preset functioning mode will be displayed if any key is pressed.

To set the functioning mode displayed:

Change the Weekly mode

Change the Manual mode

Change the Holidays mode

Change the Timed mode

Change the Antifreeze mode

Change the Off mode

Replacing the batteries

When the symbol below is displayedbticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.7 it is necessary to replace the batteries. If flashing, the device will not work, thus the batteries need to be replaced. The “dead battery” signal appears about one month before the batteries totally run out.
When replacing the batteries, the data stored will be saved.bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.11
After replacing the batteries, it is recommended to check the Date and Time of the Chronothermostat.bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.12

Putting in the batteries

The batteries will last for at least 1 year. The duration depends on the type of batteries, on the screen saver selected (See chapter 2.1.8) and on the display activation time (about 5 seconds every time a key is pressed).

Setup menu

The setup menu lets you customize some parameters or functioning modes of the Chronothermostat.

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.14

Set the Summer/Winter functioning mode

Sets the system functioning mode (default is Winter):
Summer = cooling, Winter = heating

Set the Daylight saving time
For proper operation of your system, make sure that the date and time are set correctly.

Set the measurement unit of the temperature

Sets the measurement unit of the temperature: Celsius or Fahrenheit (default is Celsius).

Enable/Disable the Remote control

Enables/Disables the remote control using a telephone actuator of the Chronothermostat (default is Enabled).
The remote contact is managed as follows:

  1. Closed= antifreeze mode activation
  2. Open= last set weekly program

Adjust the Display contrast
Adjusts the contrast of the graphic display.

Select the Screen Saver

Select the Language

Select the Temperature adjustment

This setting lets you choose the type of temperature adjustment according to the type of system.

Calibrating the thermal probe

This setting lets you calibrate the measurement of the internal and external probe.

If the external probe is not operative, the calibration menu of the internal probe will be displayed directly.
If the external probe is set for measuring the ambient temperature, the calibration menu of the external probe (internal probe inoperative) will be displayed directly.

Select the function of the external Probe

Select the function of the external probe (default is Not active).
You can select the following:

View/Reset the activation Hours

Resetting the Chronothermostat

Programming

Programming Menu

Here, you will be able to change/program the weekly profiles of the 3 weekly programs for the selected functioning mode (Summer/Winter). Within these programs, it will be possible to differentiate the temperatures around the clock and for each day of the week.
“PROGRAM 1” is set in advance but can be changed. Select the weekly program to be customized:

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.15

Rename a Weekly program

When you select this function you can customize the name of the program (maximum 13 characters).

The bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.8 keys scroll alphanumeric characters (only uppercase), numbers and special characters in the following order: A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, Z, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, space, dot, hyphen, prime.

Change a Weekly program

When you select this function you can change the selected weekly program.

Copy a daily profile

Copy the program from one day to another.

Display a daily profile

Displays the profile of the selected day.

Daily profile modification tools

Information displayed:bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.16

There are two working modes:

Create a new daily profile

It is recommended to follow the procedure described in this example step by step. It will be useful to get you acquainted with the “Modifying” and “Scrolling” modes and with the navigation keys.
Example: the creation of the following daily temperature profile for “Monday” of the “WEEK. WINTER” program.

  1. from h 00:00 to h 06:00 – 18°C (T1)
  2. from h 06:00 to h 09:00 – 22°C (T3)
  3. from h 09:00 to h 16:30 – 20°C (T2)
  4. from h 16:30 to h 22:00 – 22°C (T3)
  5. from h 22:00 to h 24:00 – 20°C (T2)

bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.19

After completing the procedure, use the “Copy from” function (See chapter 3.1.2) to copy the “Monday” profile to other days of the “WEEK. WINTER” weekly program.

Procedure:bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.20 bticino-HC-HS-HD4451-Flush-Mounted-Timer-Thermostat-FIG.21

Copy a Weekly program

This function lets you copy a weekly program into another one. For example, copy Program 1 (preset at factory) to WEEK. WINTER.

View a Weekly program

Remove a Weekly program

Reference

Download Manual:

bticino HC-HS-HD4451 Flush mounted timer thermostat User Manual

OTHER MANUALS:

bticino HC-HS-HD4451 Flush mounted timer thermostat Installation Instruction

bticino LOGO

bticino HC/HS/HD4451 Flush Mounted Timer Thermostat User Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)