Braeburn 5000 Programmable Thermostats 

Braeburn-5000-Programmable-Thermostats-Installation-Guide-PRODUCT

WARNING

Specifications

Compatibility: Compatible with low voltage single-stage gas, oil or electric heating or cooling systems, including single-stage heat pumps. This thermostat can also be used on 250mv to 750mv millivolt heating-only systems.

InstallationReplacing Existing Thermostat

Most thermostats have three parts:

Old Terminal from Existing Thermostat New Terminal for New Thermostat Terminal Description
V or RC Rc Cooling Transformer
M, 4, Rh or R Rh Heating Transformer
B B Reversing Valve (Heating)
O O Reversing Valve (Cooling)
Y Y Cooling Control
H, W or 4 W Heating Control
G or F G Fan Control
C C 24 Volt AC, Transformer Common

NOTE: This thermostat is designed for use with 24 Volt AC low voltage single-stage gas, oil or electric heating or cooling systems, including single-stage heat pumps. This thermostat can also be used on 250mv to 750mv millivolt heating-only systems. Do not use this thermostat on applications with voltages above 30 Volts AC.

Installing Your New Thermostat
NOTE: When installing this thermostat in a new location, following a few simple guidelines and the applicable building codes will give the best results. Install the thermostat in a location that provides good airflow by avoiding areas behind doors, near corners, air vents, direct sunlight or heat-generating devices. The wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction for this installation.

  1. Always turn off the power to the air conditioning and heating system prior to installing this thermostat.
  2. Locate the release latch on the bottom (not the back) of the thermostat. Press the release latch in and separate the body from the sub-base of the thermostat.
  3. Set the thermostat electronics and cover them down on a clean surface. Place the sub-base on the wall in the desired location.
  4. Using the slotted mounting holes in the sub-base, mark the placement of the mounting holes through the slots and onto the wall. Insure the wires come out of the wall into the center hole of the sub-base.
  5. After verifying the drill will not damage items in the wall, use a 3/16 drill to create the mounting holes. Gently tap the supplied plastic anchors into the holes in the wall.
  6. Place the thermostat sub-base against the wall in the desired location. Ensure the thermostat is level, the wires are inserted in the opening, and the mounting holes are aligned with the slots on the sub-base.
  7. Fasten the sub-base to the wall using the supplied screws into the plastic wall anchors.
  8. Connect wires to the quick wiring terminal blocks. Use the wiring diagram chart to insure the old and new connections are correct.
  9. To prevent electrical shorts and potential damage to the thermostat, make sure all wire connections are secure and not touching each other.
  10. Turn the thermostat body over, exposing the rear view of the circuit board.
  11. Locate the internal °F / °C switch on the circuit board. Using your fingers, flip the switch toward the preferred temperature °F / °C scale.
  12. Locate the internal fan option switch, HG (Gas) / HE (Elec) on the circuit board. This switch controls the heating system fan delay. Select gas for gas or oil-fired systems. This will allow the furnace to run for a few seconds before starting the fan. Select electric for systems with electric furnace elements that require the fan to come on immediately. Using your finger, flip the switch toward the HG (Gas) or HE (Elec).
  13. Locate the internal NORM HP switch on the circuit board. This switch configures the thermostat for normal (NORM) heating and cooling systems or heat pump (HP) systems. Using your fingers, flip the switch toward the NORM or HP.
  14. Locate the internal programming switch on the circuit board. This switch configures the programming mode for either 5-2 DAY (weekday-weekend), or full 7 DAY programming. Using your finger, gently flip the switch toward the programming option that best suits your schedule.
  15. Ensure the cover is still installed on the thermostat body, and install the unit onto the sub-base. To do so, use the mounting tabs on the top of the sub-base as a guide hinge, and close up the thermostat case by pivoting the body and cover closed. The latch on the bottom of the thermostat will click when the case is properly closed.
  16. Flip the front thermostat cover open and open the battery compartment door. (continued on page 3 continued from page 2)
  17. Locate the positive [+] ends of the batteries and match them with the positive [+] terminals located in the battery compartment. Install the two new “AA” alkaline batteries (supplied). Close the battery compartment door.
  18. Restore system power and proceed to Test Your New Thermostat.
    NOTE: If batteries were installed prior to accomplishing steps 10 through 15, you will need to reset the thermostat to register thermostat switch configurations prior to programming any user settings. Gently press the RESET button on the front of the thermostat using a paper clip or a small pencil tip.

Testing Your New Thermostat

NOTE: Test your thermostat prior to programming any user settings. Pressing The RESET button will erase any user entries previously programmed and return them to their default values

  1. Place the system switch in the HEAT position.
  2. Press the button on the keypad until the set point temperature setting is a minimum of 3 degrees higher than the current room temperature. The heating system should start within several seconds. The fan may not turn on immediately due to the heating system’s built-in fan delay.
  3. Place the system switch in the OFF position. The heating system should stop within several seconds on normal single-stage heating or cooling systems. On single-stage heat pump systems, you must wait 5 minutes for the automatic compressor short cycle protection period to expire or press the RESET button to bypass this feature for initial testing purposes. Pressing the RESET button will erase any user entries for time of day, day of the week, option settings and programming if previously programmed.
  4. Place the system switch in the COOL position.
  5. Press the button on the keypad until the set point temperature is a minimum of 3 degrees lower than the current room temperature.
  6. The cooling system should start within several seconds. Place the system switch in the OFF position. The cooling system should stop within a few seconds.
  7. Place the fan switch in the ON position. The system blower should start.
  8. Place the fan switch in the AUTO position. The system blower should stop.

programming User Settings

Default Thermostat Settings

Function Status After Reset
Operation Mode Normal Operating Mode
Temperature Hold Extended and Temporary Hold Cleared
Clock 12:00 p.m., Monday
Room Temperature 70˚ F (21.0˚ C), to be renewed within 5 seconds
Set Point Temperature According to System Switch 62˚ F (17.0˚ C) for Heat and Off 83˚ F (28.0˚ C) for Cool
Temperature Scale ˚F or ˚C dependent on switch setting
Operating Program DAY program, Monday
Low Battery Warning Off, to be renewed within 5 seconds
Temperature Differential 0.5˚ F (0.25˚ C)
Short Cycle Protection Timer Reset
Output Relays Off
Extended Hold Indefinite
Keypad Lock Unlocked
Adaptive Recovery Mode Off
Residual Cooling Fan Delay 60 seconds
Filter Check Monitor 0 days-off

Setting Current Time of Day and Day of Week

Programming User Settings cont
NOTE: It is important for you to set the current time of day (note AM/PM indicator in the display), and the current day of the week correctly to avoid problems with program execution.

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-1

  1. When in normal operating mode, press the DAY/TIME keypad button. The LCD display will be cleared except for the time, am/pm indicator, and the day of the week. The hour portion of the time will flash.
  2. Press the or button to set the current hour.
  3.  Press the DAY/TIME button again, and the minute portion of the time will flash.
  4.  Press the or button to set the current minute.
  5. Press the DAY/TIME button again. The day of the week indicator will flash.
  6. Press the or button to set the current day of the week.
  7. Press the DAY/TIME button again and the thermostat will return to normal operating mode.
    NOTE: The thermostat will return to normal operating mode automatically after 30 seconds if no key is pressed. It will also return to normal operating mode immediately if the RETURN button is pressed.

Setting Thermostat User Options
The default user options are compatible with most systems and applications. They are normally set at the time of installation and usually do not require modification under normal operating conditions. If you wish to change these settings, simply follow the instructions below.
NOTE: The temperature differential settings are the same for both the heating and cooling systems.

Setting the Temperature Differential
The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from the set point temperature before the thermostat will call for heating or cooling.

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-2

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. The LCD display will show “d1 X”, where “X” equals the ˚F / ˚C differential setting. This is the current temperature differential setting.
  2. Press the or button to set the temperature differential to your desired setting of 0.5˚, 1˚, or 2˚ F (0.3˚, 0.5˚, or 1˚ C).

NOTE: Once you have finished setting the temperature differential you can wait 30 seconds and the thermostat will automatically return to normal operation mode. Otherwise, you can press the RETURN button again to set the Residual Cooling Fan Delay. When you go directly to the next programming step, it is not necessary to press and hold RETURN for 4 seconds.

Setting Residual Cooling Fan Delay

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-3

The default setting is 60 seconds. During the COOL mode of operation, the fan will stay on for 60 seconds after the set point temperature has been satisfied, and the compressor has shut off.

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN again until “FAN XX” is displayed where “XX” is the fan delay time in seconds.
  2. Press the or button to change the Residual Cooling Fan Delay to the desired setting of 0 (disabled), 30, 60, or 90 seconds.
  3. Press the RETURN button again to set the Extended Hold Time or wait 30 seconds for the thermostat to return to the normal mode.

Setting the Extended Hold Time (see section 7)
The default setting is Long (indefinite) Hold. If the HOLD feature is activated, the current set point will be held until HOLD is released.

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “HOLD LG” is displayed where “LG” is indefinite hold. (continued on page 6)Setting the Extended Hold Time (continued)
  2. Press the or button to change the Extended Hold time from indefinite (LG) to 24 hours (SH).
  3. Press the RETURN button again to set the Filter Check Monitor or wait 30 seconds for the thermostat to return to normal mode.Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-4

Setting Filter Check Monitor (see section 7)
The default setting is 0 days (Filter Monitor disabled).

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “XXX FLT SET” is displayed where “XXX” is the Filter Monitor interval (number of days since last warning).
  2. Press the or button to change the Filter Monitor interval to the desired value of 0 (disabled), 30, 60, 90, 120, or 180 days. Press the RETURN button again to set adaptive recovery mode or wait 30 seconds for the thermostat to return to normal mode.Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-5

Setting Adaptive Recovery Mode (ARM™) (see section 7)
The default setting is OFF (Adaptive Recovery Mode disabled).

  1. In normal operating mode, press and hold the RETURN button for 4 seconds. Press RETURN repeatedly until “REC XX SE” is displayed where XX is the Adaptive Recovery Mode status.
  2. Press the or button to change the Adaptive Recovery Mode to either ON or OFF.
  3. Press the RETURN button again or wait 30 seconds for the thermostat to return to normal mode.Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-6

Setting Your Energy Saving Program

Time: 6:00 am Time: 6:00 am
MORN Heat: 70˚ F (21˚ C) Heat: 70˚ F (21˚ C)
Cool: 75˚ F (24˚ C) Cool: 75˚ F (24˚ C)
Time: 8:00 am Time: 8:00 am
DAY Heat: 62˚ F (17˚ C) Heat: 70˚ F (21˚ C)
Cool: 83˚ F (28˚ C) Cool: 75˚ F (24˚ C)
Time: 6:00 pm Time: 6:00 pm
EVE Heat: 70˚ F (21˚ C) Heat: 70˚ F (21˚ C)
Cool: 75˚ F (24˚ C) Cool: 75˚ F (24˚ C)
Time: 10:00 pm Time: 10:00 pm
NIGHT Heat: 62˚ F (17˚ C) Heat: 62˚ F (17˚ C)
Cool: 78˚ F (26˚ C) Cool: 78˚ F (26˚ C)

NOTE: For 7-day programming, the defaults follow the Weekday programming shown above. To change between 5-2 and 7-day programming, adjust the switch by following step 14 of the Installation section.
Entering Your Program – 5-2 Day Mode The 5-2 Day mode has separate Weekday and Weekend Program Groups that allow you to change the daily set point times and temperatures to meet your individual schedule needs. Weekday – allows you to program all the weekdays (M, TU, W, TH, F will show in the display) at the same time. Allows programming times and temperature settings for four set points (MORN, DAY, EVE, and NIGHT) to meet your weekday schedule needs.
Weekend – allows you to program all the weekend days (SA, SU will show in the display) at the same time. Again allows programming times and temperature settings for four set points (MORN, DAY, EVE and NIGHT) to meet your weekend schedule needs. (continued on page 8)

  1. Place the system switch in the HEAT mode of operation.
  2. Press the PROG button to enter the Program setting mode. MORN set point of the Weekday Program Group will be displayed. The display will show M, TU, W, TH, F to indicate the Weekday group is being programmed. The hour and the AM/PM indicator will be flashing.
  3. Press the or button to change the time to the desired hour in one-hour increments. Press the PROG button. The minute portion of the set point time will begin flashing.
  4. Press the or button to change the time to the desired minute in 10-minute increments. Press the PROG button. The SET temperature will begin flashing.
  5. Press the or button to change the set point temperature to the desired setting in 1º (.05˚ C) increments. Press the PROG button. The thermostat will now display the DAY set point time and temperature. Again, you will see the hour and the AM/PM indicator flashing.
  6. Follow steps 3 through 5 to set the set point times and temperatures for the periods of DAY, EVE and NIGHT.
  7. After pressing the PROG button, you will enter the Weekend Program Group. The display will show SA, SU to indicate the Weekend Group is being programmed. The hour portion of the MORN set point time and the AM/PM indicator will be flashing.
  8. Follow steps 3 through 6 to set the set point time and temperatures for the periods of MORN, DAY, EVE, and NIGHT.
  9. Place the system switch in the COOL mode of operation. The display will show COOL. Follow steps 2 through 8 to program the set point times and tempera- tures for the Weekday and Weekend groups in the COOL mode.

NOTE: To erase all entered programs, the current time of day, day of the week, and other user settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values.

Entering Your Program – 7-Day Mode
The 7-Day mode has separate Whole Week or Individual Day programming to allow you to change the daily set point times and temperatures to meet your individual schedule needs. The Whole Week programming can be used to set the main portion of your schedule, allowing you to later modify specific days of the week as required using the Individual Day programming capabilities. Whole Week – allows you to program all seven days (M, TU, W, TH, F, SA, SU will show in the display) at the same time. Then you can use the individual day programming to fine tune your program for the few set point times or temperatures that you may wish to change. Individual Days – allows you to program each day of the week individually to give you the greatest schedule flexibility. Often used to fine tune programming after initial programming. (continued on page 9)

Entering Your Program – 7 Day Mode (continued from page 8)
IMPORTANT NOTE! When in Whole Week programming, the thermostat will check if all of the days of that group have the same program set point times and temperatures. If so, the set point time and temperature of the individual set point will be displayed. Otherwise, the individual set point time and temperature will be blanked. The user is allowed to change the daily programs for this set point time and temperature by pressing the or button. This will reset all the daily programs of the group for that specific individual set point time and temperature to the startup default for that set point. Continued pressing of the or button by the user will change set point time and temperature settings as desired.

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-8

  1. Place the system switch in the HEAT mode of operation.
  2. Press the PROG button to enter Program setting mode. The MORN set point of the Whole Week Program Group will be displayed. The display will show M, TU, W, TH, F, SA, SU, indicating the whole week is being programmed. The hour and the AM/PM indicator will be flashing.
  3. If you wish to program each day individually press the DAY/TIME button to select a specific day.
  4. Press the or button to change the time to the desired hour in one-hour increments. Press the PROG button. The minute portion of the set point time will begin flashing.
  5. Press the or button to change the time to the desired minute in 10-minute increments. Press the PROG button. The SET temperature will begin flashing.
  6. Press the or button to change the set point temperature to the desired setting in 1º (.05˚ C) increments. Press the PROG button. The thermostat will now display the DAY set point time and temperature. Again, you will see the hour and the AM/PM indicator flashing.
  7. Follow steps 4 through 6 to set the set point times and temperatures for the periods of DAY, EVE, and NIGHT.
  8. Place the system switch in the COOL mode of operation. The display will show COOL. Follow steps 2 through 7 to program the set point times and temperatures for the COOL mode.

NOTE: To erase all entered programs, the current time of day, day of the week, and other user settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values.

Temperature Adjustment

Review Set Temperature

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-9

  1. Press and hold the or button. The current set point temperature will be displayed in place of the current room temperature and the indicator SET will be displayed.
  2. The display will return to normal operating mode when the or button is released. Continuing to hold the or button for 1 second or longer will allow the user to temporarily override the current programmed set point.

Temporary Program Override

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-10

  1. Press and hold or button for 1 second or longer. The entire display will flash once and the SET indicator will b  displayed. Release the or button nd press the or button again as desired to adjust the set temperature.
  2. The display will return to normal operating mode after 15 seconds or you can press the RETURN button.
  3.  The program indicator (MORN, DAY, EVE or NIGHT) will be flashing in the display, indicating that a Temporary Program Override is in effect. The Temporary Program Override will reset when the next set point time occurs or after four hours– whichever comes first.

Extended Hold (Vacation) Mode

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-11

  1. Press the HOLD button to bypass the program schedule. At the current set point temperature will be held either permanently or for 24 hours, depending on the setting selection made in section 4.
  2. Press the HOLD button again to return the thermostat to the normal program operation.
  3. The hold period will last until the hold is released as in step number 2 above, or is limited to 24 hours if the default was changed in the User Options Settings (see section 4).

Additional Operation Features

Filter Check Monitor (see section 4)

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-12

The Filter Check Monitor displays a reminder for required filter replacement or cleaning by flashing the FILT segment in the display. See instructions on your filter or heating/cooling unit for recommendations for interval settings. When the selected interval has been reached and required cleaning or replacement has been performed, press the RETURN button in any normal mode to reset the timer and turn off the warning.

Locking the Keypad

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-13

To prevent accidental or undesired adjustment of the thermostat, the Keypad The Lockout feature disables the operation of the keypad except for the backlight key. I  order to lock the keypad, press and hold both buttons together at the same time for 5 seconds. The LOCK segment in the display will flash once per second and then appear continuously in the display. The keypad is now locked. To unlock the keypad, press and hold the buttons together at the same time for 1 second. The LOCK segment will disappear and the keypad will become unlocked.

Adaptive Recovery Mode (ARM™) (see section 4)
In order to maximize comfort and energy efficiency, this thermostat is equipped with an Adaptive Recovery Mode (ARM™). This feature minimizes the amount of time required by the heating or cooling system to reach the new set point after a setback period is completed and assures your desired temperature is achieved at your set program times. This feature activates when recovering room temperature from setback programs to comfort programs, so it will only take place when the current (heating) program set point temperature is lower than the upcoming program set point temperature, or the current (cooling) program set point temperature is higher then the upcoming program set the point temperature. During ARM™, room temperature is recovered gradually by turning on the heating or cooling before the end of the setback period. The set point temperature is changed to that of the upcoming comfort program temperature. The start time of recovery is based on the difference between the current room temperature and the upcoming comfort program set point temperature. The recovery to the upcoming set point starts 10 to 15 minutes before the upcoming set point time for each degree of temperature change required, up to a maximum of 2 hours in the HEAT mode, 3 hours in the COOL mode. ARM™ does not operate when the unit is in HOLD mode, or if the program is temporarily overridden

Circulating Fan Mode–Fan Operation

Compressor Protection

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-14
This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present in the heat mode of operation on single-stage heat pump systems to protect the compressor.
NOTE: The installer can reset the thermostat and bypass the compressor protection features by pressing the RESET button. This will erase all entered programs, the current time of day, day of the week, and other user settings and should only be used during installation for testing purposes or to reset a thermostat to regain normal operation. This will return all thermostat settings to their default values.

Low Battery Detection
This thermostat requires two (2) new, properly installed “AA” Alkaline batteries to maintain the system clock and to provide proper thermostat power when 24-volt AC power fails or is not connected to the thermostat. When the batteries start to become too weak to provide proper operation, the thermostat will begin to display a low battery indicator. The low battery indicator is provided to inform the user when the batteries require immediate attention. We recommend replacing the batteries as soon as the low battery indicator appears. If the batteries are not replaced after the low battery indicator first appears the thermostat may not provide proper heating or cooling system operation. Even if the low battery indicator does not appear, the batteries should be replaced at least once a year, or if you plan on leaving the premises for over a month. This thermostat can be powered by 24 volts AC or battery power. To determine if 24-volt AC power is connected to the thermostat, refer to the installation and wiring diagram section. If you cannot determine how this thermostat is powered, call a professional service technician to determine the type of installation and the proper operation of your system.

Resetting the Thermostat
The Reset feature allows the user to completely reset the thermostat to register new manual switch settings. To erase all entered programs, the current time of day, the day of the week, and other user settings, gently press the RESET button using a paper clip or a small pencil tip. This will return all thermostat settings to their default values and register all new manual switch settings for proper operation. Non-Volatile Memory In the event of a power failure, the Non-Volatile Memory feature allows all settings to be recovered, eliminating the need to reset the temperature and differential settings. When AC power is restored after an outage, all settings are retrieved from memory and reinstated.

Status Indicators
HEAT: This will turn on whenever the system switch is in HEAT mode.
“HEAT” will flash when the heating system is running.
COOL: This will turn on whenever the system switch is in cool mode.
“COOL” will flash when the cooling system is running.

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-15

Battery Replacement

Replacing the Batteries

  1. Open the thermostat cover and locate the battery compartment door.
  2. Remove the two “AA” alkaline batteries located in the battery compartment.
  3. Install two new “AA” alkaline batteries into the battery compartment. Make sure to match the positive (+) ends of the batteries with the positive (+) terminals located in the battery compartment.
  4. Close the battery compartment and verify that the low battery indicator does not appear in the display

Troubleshooting

Wiring Diagrams

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-16

NOTE:

  1.  Transformer Common is not required for the battery-only operation of the thermostat.
  2. For heating or cooling-only systems, ignore the opposite connection.
  3. For 2-wire 24 Volt AC or 250mV – 750mV millivolt heating systems, ignore cooling connection and fan control.

Single Stage Conventional Systems (Dual Transformer)

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-17

NOTE: Transformer Common is not required for the battery-only operation of thermostat

Braeburn-5000-Programmable-Thermostats-Installation-Guide-FIG-18

NOTE:

  1. Transformer Common is not required for the battery-only operation of the thermostat.
  2. For units requiring reversing valve to be energized during heating, connect reversing valve to B terminal. For units requiring reversing valve to be energized during cooling, connect reversing valve to 0 terminal.

LIMITED WARRANTY

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are due to faulty material or workmanship for a period of five years after the original date of purchase by a professional service technician. This warranty and our liability do not apply to batteries, nor does it include damage to merchandise or the thermostat resulting from accident, alteration, neglect, misuse, improper installation, or any other failure to follow Braeburn installation and operating instructions. Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty does not include the cost of removal or re-installation. This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices.

WARRANTY FACILITY: Braeburn Systems LLC Attn: Warranty Department 2215 Cornell Avenue Montgomery, IL 60538 Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2011 Braeburn Systems LLC • All Rights Reserved • Made in China • 5000-100-009

REFERENCE:

Download Manual:

Braeburn 5000 Programmable Thermostats Installation Guide

Braeburn-logo

Braeburn 5000 Programmable Thermostats Installation Guide

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)