BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-product

BeOK TR33WIFI Large LCD Screen Smart Thermostat Instruction Manual

Beok- LOGO

BeOK TR33WIFI Large LCD Screen Smart Thermostat

BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-product

Product Overview

This series of thermostats has Floor Heating, Fan Coil, and an Integrated version, meeting the requirements under different scenarios.

Version System mode Model Application
Floor heating Floor heating EP Built-in & floor sensor, floor limit sensor + Weekly programming
WP An NC/NO dual-output + Weekly programming
WPB An NC/NO dual-output + Weekly programming+ Potential-free output
Fan Coil Heating /Cooling / Ventilation AC2 Timer task + 2-pipe system
AC2-485 Timer task + 2-pipe system + 485Modbus (optional) + Potential-free output + Room card (optional)
AC4 Timer task + 4-pipe system + 485Modbus (optional) + Potential-free output + Room card (optional)
Integrated Heating / Cooling / Ventilation/Floor heating / Floor heating + Heating AWY Floor heating & fan coil, weekly programming + Potential-free output + Timer task + 485Modbus (optional) + Room card (optional)

Display Symbols

BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.1

Temperature Control Mode(Floor Heating/Integrated)

  • User Operation Auto Mode
    In the weekly-circled programme, up to 6 heating events can be set per day. Heating events, workdays and temperature can be separately customized based on personal routines.
  • User Operation Manual Mode
    Thermostat works based on manually-set temperature, disconnecting from auto mode.
  • User OperationUser OperationTemporary Mode
    Thermostat works based on manually-set temperature temporarily and then shifts back to auto mode till next event.

User Operation

  • Power on/off : Press “ User Operation ” shortly to turn on/off the thermostat
  • Auto-mode : Press “ M ” for 3 seconds to edit auto-mode settings. (Floor Heating/Integrated)
  • Timer task: Press “ User Operation ” for 3 seconds to edit timer task. (Integrated)
  • Time setting: Press “ User Operation ” for 3 seconds to set time. (Floor Heating)
    Press “ User Operation ” twice for 3 seconds to set time. (Automatic time synch for Wi-Fi version)
  • Temp setting: Press “ User Operation ” or “ User Operation ” shortly to change setting temperature by 0.5°C.
  • Child-lock: Press “ User Operation ” + “ User Operation ” for 3 seconds to activate child-lock.
  • System mode: Press “ ” shortly to switch cooling/heating/ventilation(Fan Coil/Integrated)
    Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor heating + heating. (Integrated)
  • Temp control mode: Press “ ” shortly to switch manual/auto mode. (Floor heating)
    Press “ User Operation ” shortly to switch manual/auto mode. (Integrated, floor heating)
  • Fan speed setting: Press “ User Operation ” shortly to adjust fan speed.(Integrated)
  • ECO mode: Press“ User Operation ”shortly to set to ECO mode 18°C(65°F). (Floor heating)

Customized exclusive temperature plan – up to 6 events allowed to set per day Sail shape design-delicate and elegant Large LCD screen-better user experience 485 Modbus and room card linkage – customized equipment (optional)

Parameter

  • Supply voltage: AC100~240V; 50/60Hz
  • Power consumption: 1W Max (Wi-Fi 3W Max)
  • Temp. setting range: 5~95℃(41~99℉)
  • Floor limited range: 20~90℃(68~99℉)
  • Temp. Dif.: 0.5~10℃(1~10℉), Factory setting ±1℃
  • Ambient temperature: -5~50℃(23~122℉)
  • Protection level: IP20
  • Shell material: Anti-Flammable PC

Auto-mode Setting (Floor Heating/Integrated)

Press “ M ” for 3 seconds to edit the auto-mode setting.

Events Symbols Time Temperature
Default value Modify Default value Modify
Workdays 1 06:00 Press
“ User Operation
or “ User Operation
20℃(68℉) Press
“ User Operation
or “ User Operation
2 08:00 15℃(59℉)
3 11:30 15℃(59℉)
4 12:30 15℃(59℉)
5 17:00 22℃(72℉)
6 22:00 15℃(59℉)
Weekends 1 08:00 20℃(68℉)
2 22:00 15℃(59℉)

Advanced Setting (Usually for Professional Technicians)

Under power-off, press “ M ” for 3 seconds to enter advanced setting mode, then re-press “ M ” to switch to next mode. Press “ User Operation ” to save and exit advanced setting mode

Code Meaning “ User Operation ”or“ User Operation ”
Default Value Integrated Fan Coil Floor Heating
AC2-485 AC4 AC2 EP/WP/WPB
00 Postal address(optional) Adjustment range 0x00~0xFA 00 ×
01 -9.9~9.9℃(-9~9℉) -3℃
02 0.5~10℃(1~10℉) ±1℃
03 5~95℃(41~99℉) 50℃
04 5~47℃(41~99℉) 5℃
05 Frost protection ON: frost protection onOFF: frost protection off OFF
06 ℃/℉
07 Sensor selection IN × ×
08 Floor limited temp. 20~90℃(68~99℉) 35℃ × ×
09 Weekly programming setting 12345: 5/2 week mode 123456: 6/1 week mode 1234567: 7/0 week mode 12345 × ×
 

10

Status of potential

-free and main power outputs

00: both outputs are normally open 01: main power output is normallyclosed; potential-free output is normally open

02: both outputs are normally closed 03: both outputs are normally closed;

under power-off, frost protection is off  either

 

 

00

 

 

 

×

11 Delay time of outputs 0~5min 0 ×
 

 

12

 

 

Child-lock

00: Child-lock inactivate when screen off; lock all when child-lock activate01: Child-lock activate when screen off; lock all when child-lock activate

02: Child-lock activate when screen off; lock all except Fan Speed, Up and Down when child-lock activates

03: Child-lock activate when screen off; lock all except Power on/off when child-lock activates

 

 

00

 

 

 

 

 

 

13 Power-on-reset 00: stay power-off after Power-on-reset 01: stay power-on after Power-on-reset02: recovery after Power-on-reset 02
14 Door card status 00: turn off room card function01: set to ECO temp. after pulling room card out

02: stay power-off after pulling room

card out

00 × ×
15 Room card heatingECO temp. 10~21℃(50-69℉) 18℃ × ×
16 Room card coolingECO temp. 22~32℃(72-89℉) 26℃ × ×
17 Fan coil mode setting 00: Cooling and heating 01: Cooling only 00 ×
18 Weekly programming for Integrated 00: turn on01: turn off 01 × × ×
19 Reset Press “ ”for 3 seconds to reset /

Sensor failure

Please select work mode of sensors correctly. When it shows E0/E1 error, the thermostat will stay power-off till the error is eliminated.

  • E0: built-in sensor is short-circuited or disconnected.
  • E1: floor sensor is short-circuited or disconnected.

Timer Task Setting (Fan Coil / Integrated )

Press “ User Operation ” for 3 seconds to enter timer task setting; press “ ” to change settings;
press “ User Operation ” or “ User Operation ” to adjust parameters; press “ User Operation ” to save and exit.
BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.2

Dimensions (Unit: mm)

BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.3

Mounting Steps

The thermostat adopt pre-guide and limited snap-fit design. It is easy to mount.

  1. Release front cover by inserting a head screw-driver into bottom crack.
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.3
  2. Insert the wires and then fix these wires with screws. Suggested wire-stripping length is 7-9mm.
  3. Mount backing plate into wall cassette, put screws and then fix the thermostat.
    Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4. 1kgf.cm).
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.4
  4. Re-mount the front cover via a snap-fit connection.
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.5

Connecting Diagram

The thermostat operates at full capacity in areas with an altitude of less than 2500 above sea level. The power rating of the external load should be less than or equal to 80% rated power of the thermostat in areas with altitudes of 2500m to 4200m.

  • Floor Heating
    #TR33 WIF EP
    # TR33 EP
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.6
    #TR33-WIFI-WP
    # TR33-WP
    #TR33-WIFI-WPB
    # TR33-WPB
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.7
    Linkage control; delay time of linkage control is adjustable
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.8
    Linkage control; delay time of linkage control is adjustable
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.10
    Linkage control; delay time of linkage control is adjustable
  • Fan Coil
    #TR33-WIFI-AC2
    # TR33-AC2
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.11
    #TR33-WIFI-AC2-485
    # TR33-AC2-485
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.13
    #TR33-WIFI-AC4
    # TR33-AC4
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.15
  • Integrated
    #TR33-WIFI-AWY
    # TR33-AWY
    BeOK-TR33WIFI-Large-LCD-Screen-Smart-Thermostat-fig.16

REFERENCE

Download Manual

BEOK TR33WIFI Large LCD Screen Smart Thermostat Instruction Manual

Beok- LOGO

BeOK TR33WIFI Large LCD Screen Smart Thermostat Instruction Manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)