Beok TGW60 WIFI HEATING THERMOSTAT
Product Summary
TGW60 WiFi Heating Thermostat is WiFi touch screen thermostat with phone control. It is applied to temperature control of industrial, commercial and domestic room, and start of control heating appliances, especially floor heating systems. It can be controlled by phone. Phone systems are IOS and Android system optional.
Technical Parameter
Power Supply | 100 ~ 240V |
Current Load | ≤3A(water heating/gas boiler)
≤16A(electric heating) |
Power Consumption | <1W |
External Material | PC+ABS (flame retardant) |
Sensing Element | NTC |
Set Temp. Range | 5-95℃ |
Floor Set Temp. Range | 5-60℃ |
Accuracy | ±1℃ |
Dimension | 86x90x14mm |
Ambient Temp. | 0-45℃,5-95%RH(Non-condensing) |
Storage Temp. | -5~55℃ |
Timing Error | <1% |
Main Functions and Characteristics
- WIFI for Android & Apple iOS
- Large screen display and touch button
- Power-off memory function
- Real-time data save function
- 5+2 or 6+1or 7days six periods program schedule
- Anti-freezing function
- 3 sensor modes can be setting
- Selectable 80mmx80mm European hidden box.
- With child lock function
User Interface Explanation
User Interface Explanation(Phone Port)
Model Spec
Current Week
Loading Program |
Controlled Objects |
|
TGW60WIFI-EP |
16A |
For electric heating appliances |
TGW60WIFI-WP |
3A |
For water heating appliances |
TGW60WIFI-WPB |
3A |
For gas boiler |
Wiring Digram
Thermostat Operation Instruction
- Setting Power on/off
- Press to turn on/off the power.
- Setting Temperature
- Press to set the temperature.
- Setting the Clock
- Long press M and to set minute, hour and week.
- Pressfor adjusting.
- Setting the Manual Mode.
- Manual mode means non-programmable mode.
- Press M thenwill display in the s creen, it is in manual mode.
- Pressto set the temperature.
- Setting the Child Lock
- Long pressto enter into child lock mode,will display.
- Long pressagain, the child lock will be disappeared.
- Setting the Programmable Mode.
- Press and hold M into programmable mode. 12345 and time will display. 12345 display in the position of week means 5+2;
- Press tochange the time.
- Press M to do the temperature adjustment.
- Press to change the temperature;
- Press M to do the next period adjustment.
- Press to exit and save.
- If you want to make temporary adjustment in any period,
- press orwhen will display. When finish the setting, all will confirm automatically.
- Press M to switch operation between manual mode and programmable mode.
Period | Period Icon | Defaulted Time | Defaulted Temp. | |
Week |
1 | 6:00 | 20℃ | |
2 | 8:00 | 16℃ | ||
3 | 11:30 | 16℃ | ||
4 | 12:30 | 16℃ | ||
5 | 17:30 | 22℃ | ||
6 | 22:00 | 16℃ | ||
Weekend |
1 | 8:00 | 22℃ | |
2 | 23:00 | 16℃ |
Remark:
The defaulted temperature of period3 and period4 is the same as period2. Please change it according to the request.
Advanced Setting
In the state of power-off, press the M key and thekey for 5 seconds to enter the advanced option setting. Press M to e nter the next option, press and to adjust, and press toexit.
Display Code | Function | Setting And Options | Factory Defult |
1ADJ | Temp. compensation | -9.9-9.9℃ | -2℃ |
2SEN |
Sensor selection |
IN: Internal sensor OUT: Floor sensor
ALL: Both internal sensor and floor sensor |
IN |
3LIT | Modify the temp. limit | 5-60℃ | 35℃ |
4DIF | Temp. difference start | 0.5-10℃ | 1℃ |
5LTP | Antifreeze function | OFF:Close anti-frozen
ON:Open anti-frozen |
OFF |
6PrG |
Weekly programming mode | 0: 7 days programmable
1: 6+1 programmable 2: 5+2 programmable |
2 |
7rLE | Primary and secondary reverse selection | 00: close the main and
auxiliary reversal 02: auxiliary reversal |
00 |
8dLy | Passive linkage
output delay time |
0-5min | 0 |
9HlT | Set upper temp. limit | 35-95℃ | 60 |
RFAC |
Restore factory defaults | long press up button to adjust the display “—”, press power button to restore the factory settings |
– |
Sensor error:
Please select the right sensor mode. If select the different mode or there is error of sensor, Err will display on the LCD screen, the thermostat will stop heating till the problem is solved.
Phone Port Operation Instruction
Before the WIFI thermostat for the first time, you should set the WIFI signal and configuration through your samrt phone or tablet to allow communication between your connected devices.When the thermostat is on, long pressbutton for 5 seconds, and the thermostat display will come out. Now the WIFI icon flashes, at this time, the thermostat into the state of code.
Install the APP on the phone
- For iOS system: Login in App Store, search “Tuya Smart”, you can download it on your iphone.
- For Andriod system: Login in Google Paly, search “ Tuya Smart”, you can download it on your phone.
- Or scan below code to download:
Register Account
If you do not have an APP account yet, you can choose to register or log in via SMS verification code. Click “Creat a new account”, you will enter the Tuya Smart Platform Privacy Policy page. After you click Agree, you will officially enter the mobile phone registration page.
The system automatically determines the current country/region. You can also select the country/region manually. After entering your mobile phone number or email address, click “get verification code”. Enter the received verification code, then enter the password, and click “Finish” to register successfully.
Add device
(Bluetooth connection)
- Turn on the mobile phone’s Bluetooth, turn the device on and enter the Tuya APP. Click “Add Device” or “+” on the top right of the APP homepage to enter the “Add Device” page. It will prompt: find the device to be added (Figure 2) and follow the prompts.
- “Automatic discovery”: Search for devices (Figure 3), and add widgets as prompted on the phone page.
(WIFI connection)
When the thermostat is turned on, press and hold the button for 5 seconds, the thermostat display will show. Now, the WIFI icon flashes (slow flashing), and the thermostat enters the status of code matching.
Find the temperature control product (Bluetooth + WIFI model) in the“small household appliances. In the specific network configuration mode, click the configuration button on the page, select the WIFI that can connect to the Internet in the working area of the device, and enter it. WIFI password, click “Next”, click according to the page prompt (Figure 2), “Go to Connect”, and follow the instructions to find the prompt content (Figure 3), click “Prompt content ” and return to the Tuya APP to enter the network configuration process. In that case, the APP for the network configuration process is show (Figure 1), and the network configuration successfully display the interface (Figure 2). The device’s name with successful network configuration can be modified and the room’s location can be selected.
If the distribution network fails, the APP will display the page shown in the figure below. You can choose to add or view the help again. Note: if the connection fails, please confirm whether the temperature control device has entered the code matching state.
Thermostat APP interface display
Installation Instruction
This product is suitable for standard 80*80mm wall box and 60 mm european round box.
- Connect the power box according to the wiring diagram.
- Separate the power supply from the control board cable.
- Screw the power supply into the box of 86.
- Connect the power board to the board line, and align the buckle at 30 degrees to complete the installation.
ATT
Thank you for buying this product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.
In the box you will find
Model | TGW60WIFI-EP | TGW60WIFI-WP | TGW60WIFI-WPB |
Thermostat | √ | √ | √ |
User Manual | √ | √ | √ |
Screws | √ | √ |
√ |
External sensor | √ |
Our Service
- We offer the warranty of 24 months from the sales day.
- During the warranty, if it is belong to the quality issue, we will fix or replace them for you by free after test them.
- If it is not quality problem or beyond the warranty time, we will charge for the after-sales service.
WARNING
The symbol means the unit is being installed, it may cause electrical shock hazard during maintaining, so please make sure it is operated by the professional technical worker.
Reference
DOWNLOAD MANUAL
Leave a Reply