Introduction

The TH147E-P and TH148ELE-P thermostats can be used to control:

  • a forced air system – 2 or 3 wires
  • a hot water system with or without pump – 2 wires
  • a millivolt system – 2 wiresAube-Technologies-TH147E-P-Thermostat 

DisplayAube-Technologies-TH147E-P-Thermostat-fig-1

 

 

Features

Pump protection X X
Programmable cycle length X X
Battery replacement indicator X X
Backlit display X X
Programming:

–  Preprogrammed schedule

–  Temporary bypass

–  Time display (12 h or 24 h)

X X

X X

X X

X X

Interchangeable faceplates X X
Unoccupied mode activated remotely X
Automatic daylight savings changeover X

Installation

Note: The installation must be performed by an electrician.

Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT POWER TO THE HEATING SYSTEM.

  • Remove the old thermostat to access the wires.
  • Identify and label each wire (with the corresponding letter on the wire terminal) and remove them from the terminals.
  • If necessary, strip the end of each wire (maximum of 6 mm).

Installing the New Baseplate
Choose a location approximately 1.5 m above the floor and on an inside wall. Avoid draughty areas (top of staircase, air outlet, etc.), dead air spots (behind doors), direct sunlight or areas near concealed pipes or chimneys.Aube-Technologies-TH147E-P-Thermostat-fig-2

  1. Remove the thermostat faceplate.
  2. Loosen the locking screw in order to separate the thermostat from its baseplate (the screw cannot be completely removed).Aube-Technologies-TH147E-P-Thermostat-fig-3
  3. Gently tilt the thermostat upwards.
  4. Pass the wires through the opening of the baseplate and secure the baseplate to the wall using the appropriate screws.

Terminal Designations

R Power
W Load
Un / Un Unoccupied mode input (TH148ELE-P only)

Connecting the Heating SystemAube-Technologies-TH147E-P-Thermostat-fig-4

Unoccupied Mode Input (TH148ELE-P only)

TH148ELE-P has an input that can be used to lower the temperature when the house is unoccupied. You can connect an Aube’s CT240 telephone controller (optional) or another remote control system.
When the thermostat receives a 12-VDC signal, it switches to the unoccupied mode where the setpoint programmed for that mode is used (see section 5). When the signal is removed, the thermostat returns to the previous mode.

Connecting to CT240 
Connect TH148ELE-P terminals UN and UN to CT240 terminals A and C (no polarity to observe).

Connecting to a Home Automation System
Connect TH148ELE-P terminals UN and UN to a 12-VDC circuit as shown (no polarity to observe).

Installing the Batteries:Aube-Technologies-TH147E-P-Thermostat-fig-6

  1. Gently pull out the battery cover.
  2. Install the batteries as shown. Observe the polarity.
  3. Re-install the battery cover. You will hear a clicking sound.

After the batteries are installed, the thermostat performs a series of tests for approximately 5 seconds.
Afterwards, the thermostat displays the temperature. It is possible that the displayed temperature is higher than the ambient temperature if you are holding the thermostat in your hands. Once installed on the wall, the thermostat will display the ambient temperature. The time and day settings flash to indicate that they must be set (see sec-tion 4.1).

Completing the InstallationAube-Technologies-TH147E-P-Thermostat-fig-7

Basic Functions

Backlight 
The display illuminates for 12 seconds when the backlight button or any other button is pressed.

Displaying the Temperature
The actual (measured) temperature is normally displayed. To view the setpoint temperature, press once on either of the buttons. The setpoint, along with the Aube-Technologies-TH147E-P-Thermostat-fig-8icon, will be displayed for the next 5 seconds.

Setting the Temperature 
Press one of the Aube-Technologies-TH147E-P-Thermostat-fig-9 buttons until the desired temperature is displayed.

Comfort and Economy
Temperatures The thermostat has 2 preset temperature buttons:

  • Comfort Aube-Technologies-TH147E-P-Thermostat-fig-10temperature
  • EconomyAube-Technologies-TH147E-P-Thermostat-fig-11 temperature

To set the thermostat at the Comfort or Economy temperature, press the corresponding preset button. The corresponding symbol will be displayed.
The following table shows the use and the factory setting of each preset button.

Button Intended use Default setting
Aube-Technologies-TH147E-P-Thermostat-fig-10 Comfort (when the occupant is awake and at home) 21°C
Aube-Technologies-TH147E-P-Thermostat-fig-11 Economy (when the occupant is absent or asleep) 17°C

To modify the Comfort or Economy temperature:

  • Set the desired temperature using the buttons.
  • Press and hold the appropriate preset button until the corresponding symbol is displayed.

Control Mode

Manual
Use this mode to set the temperature manually. To use this mode, press Mode to Aube-Technologies-TH147E-P-Thermostat-fig-12display and set the desired temperature using the Aube-Technologies-TH147E-P-Thermostat-fig-9buttons or theAube-Technologies-TH147E-P-Thermostat-fig-10Aube-Technologies-TH147E-P-Thermostat-fig-11 buttons.

Automatic
Use this mode to set the temperature according to the programmed schedule (see section 4.3). To place in Automatic mode, press Mode to display Aube-Technologies-TH147E-P-Thermostat-fig-13.
Temporary Bypass
If you modify the setpoint temperature when the thermostat is in automatic mode, the new temperature will be used for the next 2 hours. Afterwards the thermostat will return to the automatic
mode and use its current temperature setting. The icon flashes during the bypass.

Unoccupied (TH148ELE-P only)
To place the thermostat in Unoccupied mode, see section 2.5. When the thermostat is in this mode, the unoccupied mode setpoint is used and the icon is displayed.
Temporary Bypass
If you modify the setpoint temperature when the thermostat is in unoccupied mode, the new temperature will be used for the next 2 hours. Afterwards, the thermostat will return to the unoccupied
mode setpoint. The icon flashes during the bypass.

Low-battery Indicator
An icon appears when the batteries need replacement. This icon will flash for 60 days, then the thermostat will cut power to the heating system. The icon disappears once the batteries are replaced. After replacing the batteries, re-adjust the clock and day (see section 4.1). For TH148ELE-P model, re-adjust the date also
(see section 4.2). The rest of the settings are unaffected when the batteries are removed.Aube-Technologies-TH147E-P-Thermostat-fig-15

Programming

Setting the Clock and Day

  • Press Clk for 3 seconds. The hour display flashes.
  • Set the hour usingAube-Technologies-TH147E-P-Thermostat-fig-9 .
  • Press Clk. The minute display flashes.
  • Set the minutes usingAube-Technologies-TH147E-P-Thermostat-fig-9.
  • Press Clk. The day display flashes.
  • Set the day using Aube-Technologies-TH147E-P-Thermostat-fig-9.
  • Press Exit to exit the programming mode.

Setting the Date (TH148ELE-P only)
This setting is necessary only if you use the automatic daylight savings changeover (see section 5).

  1. Press Clk for 3 seconds. The time setting is displayed.
  2. Press Clk for 3 seconds again. The year setting is displayed.
  3. Set the year usingAube-Technologies-TH147E-P-Thermostat-fig-9and press Clk to the month setting.
  4. Set the month using Aube-Technologies-TH147E-P-Thermostat-fig-9and press Clk to display the date setting.
  5. Set the day usingAube-Technologies-TH147E-P-Thermostat-fig-9.
  6. Press Exit to exit the programming mode.Aube-Technologies-TH147E-P-Thermostat-fig-16

Schedule

When the thermostat is placed in automatic mode, it switches between the Comfort temperature and the Economy temperature according to the programmed schedule. You can set a different pro-gram for each day of the week. The following schedule has been pro-grammed in the thermostat as follows:Aube-Technologies-TH147E-P-Thermostat-fig-17

Modifying the Schedule

  1. If not already done, set the Comfort and Economy temperatures (see section 3.4).
  2. Press Pgm. The program for Monday will appear and the first period (0:00 a.m. to 1:00 a.m.) is selected (flashes). Each period is a one-hour interval.
    Note: If you wish to use the same program every day, press Pgm for 3 seconds to select all the days of the week.
  3. Press Aube-Technologies-TH147E-P-Thermostat-fig-18 to advance to the next or preceding period respectively.
  4. Select the Comfort or Economy temperature by pressing on the corresponding button ( Aube-Technologies-TH147E-P-Thermostat-fig-10orAube-Technologies-TH147E-P-Thermostat-fig-11 ).
  5. Repeat steps 3 and 4 as required.
  6. To modify the program for another day, press Pgm until the day is selected and repeat steps 3 to 5.
  7. Press Exit to exit the programming mode.

Configuration

  1. Press the backlight button until the configuration menu appears (3 seconds).
  2. To go to the next parameter (menu item), press the backlight button (1 second).
  3. To modify a parameter, pressAube-Technologies-TH147E-P-Thermostat-fig-9 .
  4. Repeat steps 2 and 3 if necessary.
  5. To end, press the backlight button until the configuration menu disappears (3 seconds).
DISPLAY DESCRIPTION DEFAULT SELECTIONS
   Time display 12 h 12 h or 24 h
Pump protection 1 Off On or Off
Automatic daylight savings

changeover 2 (TH148ELE-P only)

Off On or Off
Unoccupied mode temperature

setting 3 (TH148ELE-P only)

10°C 5°C to 28°C
  Number of cycles per hour 4 4 2, 3, 4, 5 or 6
1 When pump protection is On, the thermostat will activate the heating sys- tem for 15 seconds if it has not been activated for the past 24 hours.

2 Daylight savings time starts on the last Sunday of March and normal time starts on the last Sunday of October.

3 See section 2.5.

4 The corresponding cycle lengths are: 2=30 min., 3=20 min., 4=15 min., 5=12 min., 6=10 min. Select the cycle according to the type of heating: gas boiler <30kW: 10 minutes; oil boiler: 20 minutes

Technical Specifications

  • Power supply: 2 LR6 (1.5V) Alkaline batteries
  • Maximum load: 5 A (resistive), 0.95 A (inductive) @ 240 VAC
  • Power across UN terminals: 20 mA @ 12 VDC
  • Setpoint range: 5 to 28°C
  • Display range: -10 to 50°C
  • Display resolution: 0.5°C
  • Accuracy: ± 0.5°C
  • Cycle length: 10, 12, 15, 20 or 30 minutes (programmable)
  • Conformity: IEC60730-1
  • Storage temperature: -20 to 50°C
  • Dimensions: 127 mm x 75 mm x 28 mm

Warranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube’s option).
If the product is defective,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
  2. call Aube Technical Support at 33 (0) 1 34 07 99 00. Technical Support will make the determination whether the product should be returned to the following address: 10 rue Ampère, 95500 Gonesse, France, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or mal-function was caused by damage which occurred while the product was in the possession of a consumer.
Aube’s sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI-DENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some regions do not allow the exclusion or limita-tion of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT-ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from region to region.
If you have any questions concerning this warranty, please write Aube, 705 Montrichard, Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada.

Technical Assistance

For any questions regarding the product installation or operation, contact our technical support team at
Tel.: 33 (0) 1 34 07 99 00
Fax: 33 (0) 1 34 07 99 19
Email: [email protected]
For more information on our products, visit us at www.aubetech.com

Reference

Download manual

Aube Technologies TH147E-P Thermostat User Guide

Aube-logo

Aube Technologies TH147E-P Thermostat User Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *