Delta Dore 8000-TAP-BUS Zone Thermostat
INSTALLATION
Since the temperature measurement sensor is inside the box, you must install the thermostat flush-mounting box:
- on an accessible wall at a height of 1.50 m
- away from heat sources (fireplaces, sunlight) and draughts (windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact with the outdoors or with an unheated room (e.g. garage, etc.) The sleeve output in the flush-mounting box must be blanked off (with mastic) in order to avoid unwanted air movements that could bias the sensor reading.
- Switch off the installation.
- Separate the box from its base unit by pushing the pin using a screwdriver.
- Unscrew the locking screw (captive screw).
- Separate the box from its base unit.
- Connect the bus from the technical unit to the terminal located on the base unit, then attach the box to the flush-mounting box (centre distance 60 mm).
Note: the base unit must be attached using 3 screws. - Refit the thermostat back on its base unit.
- Switch the installation back on.
ASSOCIATION OF THE THERMOSTAT WITH THE TECHNICAL UNIT
- Turn the selector knob to
.
- Press and hold the 2nd button from the left for 3 seconds. Release.
- The screen displays Ln01. Press 0K to confirm the association.
- The screen displays CF20. Press 0K to open the setting, then press + and – to select the output to which the room thermostat will be associated. Confirm with 0K.
- The screen displays CF21. Press 0K to open the setting, then press + and – to select the type of transmitter. Confirm with 0K.
- The screen displays CF22. Press 0K to open the setting, then press + and – to select the limitation value. Confirm with 0K.
Press or turn the selector knob to exit the active mode.
![]() |
Output number | 1 to 16 depending on the system. ‘–‘ is displayed if none are allocated. | |
![]() |
Transmitter type | 0 | Underfloor heating (by default) |
1 | Heater | ||
![]() |
Heating percentage limitation | From 10 to 100% in increments of 10 (100%= No limitation, by default). |
THERMOSTAT CONFIGURATION
- Turn the selector knob to
.
- Press 0K.
- The screen displays CFOI.
- Press + or – to select the menu.
- Press 0K to enter the setting mode, then + and – to perform the setting.
![]() |
Master thermostat | Zone thermostat |
Temperature management | Controlled zone | Controlled zone |
On/Off management | All zones | Controlled zone |
HEAT/COOL mode management | All zones | – |
![]() |
Correction of the measured temperature | +/- 5°C in increments of 0.1°C (0°C by default) | |
![]() |
Temperature displayed in normal mode | 0 | Setti ng display (default selection) |
1 | Display of the measured temperature. | ||
![]() |
Ban on the Cool regulation on the Thermostat’s thermal zones (if SW2 = ON on the technical unit) | 0 | No ban (default selection) |
1 | Ban | ||
![]() |
Display the status (ON) of the associated output | 0 | No (default selection) |
1 | Yes | ||
![]() |
Thermostat type | 0 | Zone thermostat (default selection) |
1 | Master thermostat |
- CF03: only appears in Heat/Cool generation mode (SW2=ON, refer to the technical unit manual) and for underfloor heating (CF21 =0).
- CF05: The Master thermostat enables centralised ON/OFF and HEAT/COOL operations to be performed (according the the technical unit’s configuration).
![]() |
Activation of the door/window magnetic contact function (the room thermostat switches to Frost Protection mode if the door/window magnetic contact is activated). | 0 | Not activated |
1 |
Active (default selection) – Display of the ![]() |
||
![]() |
This menu is only available if CF06 = 1. The symbol ![]() |
0 | Not flashing |
1 | Flashes in case of detection (default selection) | ||
![]() |
‘Presence detection’ function (the thermostat setti ng is lowered if no presence is detected). | 0 | Not activated |
1 | Activated (default selection) | ||
![]() |
Displays the time and date in the 12h/24h format | 0 | 12h (AM/PM) |
1 | 24h (default selection) | ||
![]() |
Standby mode | 0 | Display off after a 10-second time-out period |
1 | Display illuminated continuously (default selection) | ||
![]() |
Backlighting | 0 | Deactivated |
1 | When activated, it goes out after a 5-second time-out period (default) | ||
![]() |
Output number | 1 to 16 depending on the system. ‘–‘ is displayed if none are allocated. | |
![]() |
Transmitter type | 0 | Underfloor heating (by default) |
1 | Heater | ||
![]() |
Heating percentage limitation | From 10 to 100% in increments of 10 (100%= No limitation, by default). |
SETTING THE CLOCK
- Turn the selector knob to
.
- Set the year with + and – and confirm with 0K.
- Set the day and month with + and – and confirm with 0K.
- Set the hour value with + and – and confirm with 0K.
- Set the minutes value with + and – and confirm with 0K.
- Back to the AUTO, Manual or Shutdown mode.
Press to return to the previous setting.
You can decide not to use the calendar function (no automatic changeover between summer and winter). In this case, when you select the year, select by pressing on -.
LOCKING DOWN SETTINGS
- From the
,
,
or
modes.
- Press and hold the ‘i’ button for 5 seconds. The
symbol appears.
- In Lock mode, only the Information button ( i ) is active.
- To unlock, press and hold the i button for 5 seconds. The
symbol disappears.
RETURN TO INITIAL SETTINGS
DELETING THE ASSOCIATION OF THE THERMOSTAT WITH THE TECHNICAL UNIT
- Turn the selector knob to
.
- Press and hold the 2nd button from the left for 3 seconds. Release.
- The screen displays Ln01. Press 0K.
- The screen displays CF20. Press 0K to open the setting, then press + and – to select ‘CF20 = –‘
- Press 0K.
Press or turn the selector knob to exit the active mode.
DELETING ALL THE ASSOCIATIONS WITH THE TECHNICAL UNIT
- Turn the selector knob to
. Press and hold the 2nd button from the left for 3 seconds for 5 seconds. Release.
- The screen displays Ln01. Press + to display Ln05.
- Press 0K. The screen displays rSt. Release. Press and hold 0K for 3 seconds. rSt flashes for 2 seconds. Release.
- Turn the selector knob to exit.
Press or turn the selector knob to exit the active mode.
INITIALISING THE THERMOSTAT PARAMETERS
This menu restores the system to factory settings.
- From the
(or OFF) mode. Simultaneously press the 1st and 4th buttons from the left (i) for 10 seconds. Release.
- The screen displays rSt1. Press and hold 0K for 3 seconds until the rSt1 display flashes. Release.
The system automatically returns to OFF mode.
TROUBLESHOOTING
When a defect is detected on the system, the symbol flashes on the thermostat display.
Press ‘i’ to display the type of defect.
Error messages
![]() |
Address error. Several products were as- signed to the same output (CF20). |
![]() |
Thermostat internal sensor shorted. |
![]() |
Thermostat internal sensor cut off. |
![]() |
Error on the outdoor sensor associated with the thermostat channel. |
TECHNICAL CHARACTERISTICS
- Power supply by the bus, 24V
- Clock backup during power failure: 1O hours (by capacitor)
- Bus Input/output 2 wires
- Class Ill insulation
- Dimensions: 81 x 135 x 22 mm
- Degree of protection: IP 30
- Surface-mounted or on flush-mounting box
- Installation in an environment with normal pollution levels
- Storage temperature: -100C to +700C
- Operating temperature: OOC to +400C