WUNDATRADE E02 Touch Screen Programmable Thermostat
Over View
Set the time and day of the week
Press the clock symbol for 5 seconds. The minutes will start flashing – use the up
down symbols to change minutes as required and confirm your choice by pressing the
symbol
The hour will now flash, repeat the same process to adjust and confirm by pressingthe key. A number between 1 to 7 will now start flashing on the left-hand side of the screen
1 = Monday, 7 = Sunday. Use the up down symbols to change as required and confirm your choice by pressing the
symbol. The time and day are now set.
Second Choose either a 5, 6 or 7-day cycle
The programmer offers you the choice of 6 heating events each day of the week with the choice of different temperatures in each event – either for 5 days of the week plus all-day heating on days 6 and 7 (the weekend) with two heating events.
OR the same on/off timing for days 1 – 6 plus day 7 with all-day heating.
OR the same 6 heating events for all 7 days. The programmer is set at the factory for the 5 plus 2 cycles.
Copying the 1- 5 settings for 6 or all 7 days
PRESS TO TURN OFF then press
and menu
symbol together you are now in advanced settings. Now press menu
symbol 5 times to display PrG – you can now set days 6 or days 6 & 7 to be the same as days 1- 5 by pressing
arrow symbols. When the screen shows day 6 with days 1 – 5 OR days 6 & 7 with days 1- 5 you are finished. Switch the unit OFF and back ON to return to the main screen by pressing symbol.
Setting Thermostat
To start programming press the menusymbol for 5 seconds – the sun
symbol will appear on the left-hand side of the screen together with the time that the first event will start. You can change the time by using the
up and down
symbols as required and confirm by pressing the menu
symbol.
Next is the temperature you require during the first heating event session – use the up and down
arrow symbols until satisfied and then confirm by pressing the menu
symbol. There are 6 heating event times to input and 6 temperature settings to confirm – if you make a mistake press the menu
symbol repeatedly and go through the complete cycle again until you return to the required place.
Function
Manual override mode
press menusymbol until hand
symbol appears. The scheduled period is overridden, set the temperature to your individual requirements using
arrow symbols and the thermostat will operate at this temperature permanently.
Clock controlled program mode
To exit the manual override press menu symboluntil clock symbol appears. The thermostat will operate automatically according to the programmed temperature and time.
single period manual override comfort mode
While in clockcontrolled mode press
arrow symbols until the clock
and hand
symbols appear together. This enables you to manually override the scheduled heating event’s temperature setting, so the temperature can be temporarily changed for a single heating event, the ‘comfort mode’ temperature is reset at the next heating event when the thermostat will return to the scheduled program.
Keylock function.
Once thermostat has been programmed, pressarrow symbols together for 5 seconds to lock the touch screen, and the keylock symbol
will be displayed. Repeat these steps to unlock touch screen.
Programming: 6 heating event Time & Temperature
Please note:
If using an external floor probe to limit floor temperature, then advanced settings ‘SENSOR MODE’ must be set to ‘ALL’ and the ‘ADJUST LIMITATION TEMPERATURE VALVE’ be set to the desired limit temperature, i.e. 270C for wood flooring.
Advanced settings: Turn the thermostat OFF by pressing the ON/OFFsymbol. Then press and hold
menu symbol while turning the thermostat back on (by pressing
symbol once) until the thermostat enters the ‘advanced settings’ mode. Press menu
symbol to advance to the required function. Press
ymbols to change individual function settings. To save settings and EXIT this mode, press ON/OFF
symbol.
Key/ symbol to open | No. of times to press | Symbol | Function | ![]() |
|
![]()
|
1 | 1Adj | 1 Adj Measured temperature display and adjustment |
Adjusts current measured temperature value. Range +/- 9.9O C |
|
2 | 2SEN |
2SEN |
Sensor selection |
IN : Built in sensor – shows & ONLY measures air temp
OUT : Floor sensor – shows & ONLY measures probe temp (can be in floor or probe housing) ALL : Both sensors – shows air temp or set probe temperature (used as a max temperature for floors – floor sensor is limiter) |
|
3 | 3Lir | 3LIT | Adjust limitation temperature value | Adjust limitation value range 5 – 60OC (Probe limit temperature, i.e. 270C for wood floors) | |
4 | 4diF | 4diF Switching differential | Adjusts switching differential setting range 0.5 – 10OC | ||
5 | 5Lrp | 5LTP Enabling/disabling frost setting when unit is off |
Switches frost setting function ON/OFF |
||
6 | 6PrG | 6PRG Daily timer sequence | Selects 5/2 day mode, 6/1 day mode, 7 day mode OR OFF | ||
7 |
7rLE |
7RLE Not available on this model. Potential free output and main output synchronous/ asynchronous direction |
Do not adjust KEEP FACTORY SETTING = 00 |
||
8 | 8dLy | 8DLY Not available on this model. Potential free time lapse output time | Do not adjust
KEEP FACTORY SETTING = 0 |
||
9 |
9Hri |
9HIT | Max temperature setting value |
Adjusts maximum temperature setting value from 35 – 90OC |
|
10 |
AFAC |
AFAC Reset to factory settings |
Press |
NOTE: If “ERR” is displayed on the screen when the thermostat is first turned on – enter advanced settings (as described above) and advance to function “2SEN” . Press symbol so that “IN” reads on the screen. Switch the unit OFF and back ON to clear and the thermostat will return to normal working.
Most other adjustments should be made by a qualified person