Honeywell Home CM927 Programmable Thermostat 

Honeywell Home-CM927-Programmable-Thermostat-product

PRODUCT SPECIFICATION SHEET

The CM927 thermostat is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments.
It can be used as part of a system in conjunction with combi boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone values and electric heating systems (<10A). In combination with other CM927 room units and HC60NG receivers it can be used to control multi-zone applications (up to 4 zones).
The radio frequency-controlled CM927 system pack consists
of a room unit CMT927A and a relay box R6660D (HC60NG). No wiring to the room unit is required. The installer only needs to wire the relay box to the controlled device (e.g. boiler) and mount the room unit in a suitable location where RF communication is reliable. The CM927 uses reliable RF communication technology in the 868MHz band.
The CM927 extra large LCD display, dynamic text display and
controls layout are identical to the CM907 ‘wired’ thermostat.
The unit is ideal for consumers who want reliable and precise temperature control from a modern looking, simple to program and easy-to-use product.

FEATURES

CONTROLS/DISPLAY LAYOUT

Room Unit Layout:

Honeywell Home-CM927-Programmable-Thermostat-fig.1

  1. Day & Date Display
  2. Time Display
  3. Dynamic Text Display (DTD)
  4. Burner On Indicator
  5. Battery Low Indicator
  6. Temperature Display
  7. Temperature Change Buttons
  8. Information Enquiry Button
  9. Slider Switch
  10. Green OK Button
  11. Program Buttons
  12. Battery Cover
  13. Battery Compartment
  14. Holiday Button
  15. Party Button
  16. day Off Button
  17. Copy Day Button

SPECIFICATIONS

ELECTRICAL

RF

ENVIRONMENTAL & STANDARDS

TEMPERATURE CONTROL

TIME SETTING/PROGRAMMING

INSTALLER SET-UP

To enter the installer set-up mode:

Honeywell Home-CM927-Programmable-Thermostat-fig.2

  1. Move the slider switch to the OFF position.
  2. Press and hold the INFO i button and the two program buttons ‘< >’ together.
  3. the unit will display the first parameter of the installer parameter group category 1 (from n.1 to n.19).
  4. Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made.
  5. Press the green OK button to confirm this change and the display will stop flashing.
  6. Press the + button to go to the next parameter.
  7. Press the program button > to go to category 2 in the Installer mode (from n.1 to n.14).
  8. To exit the installer mode, move the slider switch to the AUTO or MAN positions.

In the Installer set-up we can:

Specific Applications Setting What do you need to change?
Cycle/ Hour Minimum ON time

(in minutes)

Note : All parameters listed below belong to category 2 – System Parameters (see Installer Parameters Table)
Heating Gas Boilers (<30KW) 6 1 No changes required
Oil Boiler 3 4 1.   Set Minimum ON Time to 4 minutes.

2.   Set Cycle/Hour to 3.

Thermal Actuator 12 1 Set Cycle/Hour to 12.
Zone valve 6 1 No changes required.
Air conditioning 1.   Configure the thermostat to allow switching between heating and cooling modes (set parameter n.4:HC to 1)

2.   Set the thermostat accordingly to the required mode of operation (heating or cooling) by pressing the TEMP  or  buttons together for 5 seconds. Modify the cooling program

as required.

Heat Pump/ Air conditioner 3 4 1.   Set Minimum ON Time to 4 minutes.

2.   Set Cycle/Hour to 3.

Fan coil 6 1 No changes required.
Special Features Description Setting
Optimisation (Variable Start Time) The thermostat will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period. The system will restrict the start time to a max of 2 hours. To enable: Set parameter 8:OP (category 1) to 1.
Heating or Cooling Operation This product can be used for heating or cooling applications. If you select cooling mode the control algorithm and factory default program will be modified. You can independently modify the heating and cooling profile. To enable: Set parameter 4:HC (category 2) to 1.
Summer/Winter Auto time change This feature moves time automatically on the last Sunday of March and the last Sunday of October. The feature is factory enabled. To enable: Set parameter 3:tC (category 1) to 1.
Temperature Offset If the thermostat is located in a particularly hot/cold location for reliable signal transmission reasons then the measured/displayed temperature can be adjusted by +/- 3°C. This is useful if the homeowner wants the reading to match another appliance temperature display. Set parameter 12:tO (category 1) to the required

offset value.

Upper/Lower Temperature Limit The normal upper temperature limit of 35°C can be reduced to 21°C to save the homeowner energy. The normal lower limit of 5°C can be increased up to 21°C to protect inhabitants from cold. Set parameter 6:uL (category 1) to the desired upper limit.

Set parameter 7:LL (category 1)

to the desired lower limit.

INSTALLER PARAMETER TABLES

Parameter Installer Set- Up Number / Abbreviation (Press + or – keys to select) Factory Setting Optional Setting
Category 1 Parameters – Room Thermostat Settings
Display Description Display Description
AM-PM / 24hr Display 1:Cl 24 24 hr clock display 12 12 hr AM / PM clock display
RESET Time / Temperature Program 2:rP 1 Time / Temperature profile set to factory default

Changes to 0 when one of the time/temp profiles are changed

0

 

1

Time / Temperature are as programmed To restore the factory profile set to 1
Automatic Summer/Winter Time Change 3:tC 1 Automatic Summer/Winter Time Change Enabled 0 Automatic Summer/Winter Time Change Disabled
LCD Backlighting 5:bL 1 Backlighting Enabled 0 Backlighting Disabled
Upper Temperature Limit 6:uL 35 35°C Upper Temp. Limit 21 to 34 21°C to 34°C adjustment in 1°C steps
Lower Temperature Limit 7:LL 5 5°C Lower Temp. Limit 6 to 21 6°C to 21°C adjustment in 1°C steps
Optimisation 8:0P 0 Optimisation disabled 1 Optimisation enabled
Temperature Offset 12:tO 0 No offset -3 to +3 -3°C to +3°C adjustment in 0.1°C steps
Proportional Band Width 13:Pb 1.5 1.5°C Proportional Band 1.6 to 3.0 1.6°C to 3.0°C adjustment in 0.1°C steps
Reset Parameters to Factory Defaults 19:FS 1 All settings held are the factory defaults.

Changes to 0 when one of the parameter values are changed

0

 

 

1

Settings are as modified above

 

 

To restore the factory profile set to 1

Parameter Installer Set- Up Number / Abbreviation (Press + or – keys to select) Factory Setting Optional Setting
Category 2 Parameters – System Settings (press the > button to access this category)
Display Description Display Description
Minimum boiler ON Time 1:Ot 1 1 minute minimum ON time 2 to 5 Selection of 2,3,4 or 5 minutes minimum ON time
Cycle Rate 2:Cr 6 6 cycles per hour (cph) 3, 9 or12 Selection of 3,9 or 12 cph
Heat / Cool Change 4:HC 0 Disabled 1 Enabled
Pump Exercise 5:PE 0 Pump Exercise Disabled 1 Pump Exercise Enabled
System Synchronisation 6:Sn 0 Standard operation of the Room Unit 1 Room unit configured as Synchroniser
Loss of Communication Instruction 7:LC 0 Relay Off 1 Relay 20% on / 80% off
The following parameters are for the control of other Honeywell Wireless products such as Wireless Underfloor Heating controls and Wireless Radiator controls. For more information please contact Honeywell sales.
Room Temperature Sensor Use 8:Su 0 HC60 Control 1,2,3 or 4 1  – HR80/HM80 control with own/remote sensor (no temperature displayed)

 

2  – Hr80/HM80/HCE80 control with CM Sensor

 

3  – HC60 control and HR80/HM80/ HCE80 control with own/remote sensor

 

4  – Hr80/HM80/HCE80 control with own/ remote sensor (temperature displayed)

HR80 Window-Open Function 9:HO 0 Disabled 1 Enabled
HR80 Local Override 10:HL 1 Enabled 0 Disabled
Maximum Flow Setpoint 11:uF 55 55°C Maximum Flow Temp. 0 to 99 0°C to 99°C adjustments in 1°C steps
Minimum Flow Setpoint 12:LF 15 15°C Minimum Flow Temp. 0 to 50 0°C to 50°C adjustments in 1°C steps
Mixing Value Run Time 13:Ar 150 150 seconds 0 to 240 0 to 240 sec. adjustments in 1sec steps
Pump Overrun Run 14:Pr 15 15 minutes 0 to 99 0 to 99 mins adjustments in 1min steps

DIMENSIONS

Honeywell Home-CM901-Programmable-Thermostat-FIG.4INSTALLATION

Honeywell Home-CM927-Programmable-Thermostat-fig.3WIRING

The R6660D relay box is designed for fixed wiring only and must be installed in accordance with latest l.E.E. regulations.
Ensure the wiring connection to the supply is via a fuse rated at no more than 10 amps and a Class “A” switch (having contact separation of at least 3 mm in all poles).
IMPORTANT

  1. The installer must be a trained service engineer
  2. Disconnect the power supply before beginning installation

Honeywell Home-CM927-Programmable-Thermostat-fig.4

ORDERING SPECIFICATION

Description Model Logo Literature Availability Spec Sheet
7-day RF system pack (includes HC60) CMT927A1015 Honeywell French & Dutch. Sep 06 ENOH8556
7-day RF system pack (includes HC60) CMT927A1023 Honeywell French Oct 06 ENOH8556
7-day RF system pack (includes HC60) CMT927A1031 Honeywell Spanish Feb 07 ENOH8556
7-day RF system pack (includes HC60) CMT927A1049 Honeywell English (UK) Oct 06 ENOH8556
7-day RF system pack (includes HC60) CMT927A1056 Honeywell Italian. Sep 06 ENOH8556
7-day RF system pack (includes HC60) CMT927A1064 Honeywell HUN / GER Mar 07 ENOH8556
7-day RF system pack (includes HC60) CMT927A1072 Honeywell CZ / SK / POL Mar 07 ENOH8556
7-day room unit spare CMS927B1015 Honeywell French & Dutch. Sep 06 ENOH8556
7-day room unit spare CMS927B1023 Honeywell French Oct 06 ENOH8556
7-day room unit spare CMS927B1031 Honeywell Spanish Feb 07 ENOH8556
7-day room unit spare CMS927B1049 Honeywell English (UK) Oct 06 ENOH8556
7-day room unit spare CMS927B1056 Honeywell Italian. Sep 06 ENOH8556
7-day room unit spare CMS927B1064 Honeywell HUN / GER Feb 07 ENOH8556
7-day room unit spare CMS927B1072 Honeywell CZ / SK / POL. Mar 07 ENOH8556
HC60 Spare R6660D1017 Honeywell French & Dutch. Sep 06 ENOH8556
HC60 Spare R6660D1025 Honeywell French Sep 06 ENOH8556
HC60 Spare R6660D1033 Honeywell Spanish Sep 06 ENOH8556
HC60 Spare R6660D1041 Honeywell English (UK) Sep 06 ENOH8556
HC60 Spare R6660D1058 Honeywell Italian. Sep 06 ENOH8556
HC60 Spare R6660D1009 Honeywell Eng / Ger Sep 06 ENOH8556

Honeywell Control Systems Limited http://europe.hbc.honeywell.com
Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom

REFERENCE:

Download Manual:

Honeywell Home CM927 Programmable Thermostat Product Specification Sheet

Other manuals:

Honeywell Home CM927 Programmable Thermostat User Guide

Honeywell-Home-LOGO

Honeywell Home CM927 Programmable Thermostat Product Specification Sheet

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)