INTRODUCTION

The thermostat is an electronic PWM/PI thermostat for temperature control by means of an NTC sensor located either externally or internally within the thermostat. The thermostat is for flush mounting in a wall socket. A baseplate for wall mounting is also available. This thermostat can be used as a controller for electric room heating pursuant to EN 50559.

Content

  • Thermostat
  • Sensor

IMPORTANT SAFETY INSTRUCTIONS

Warnings
To avoid electric shock, disconnect the heating system power supply at the main panel before carrying out any work on this thermostat and associated components.

Installation must be carried out by qualified personnel in accordance with appropriate statutory regulations (where required by law). Installation must comply with national and/or local electrical codes.

Cautions
This instruction must be observed, otherwise the liability of the manufacturer shall be voided. Any changes or modifications made to this thermostat shall void the liability of the manufacturer. Maximum product lifetime is achieved if the product is not turned off but set at the lowest possible set point / frost protection when heat is not required.

Notice
The language used in the original documentation is English. Other language versions are a translation of the original documentation. The manufacturer cannot be held liable for any errors in the documentation. The manufacturer reserves the right to make alterations without prior notice. Content may vary due to alternative software and/or configurations.

Thermostat placement

Mounting of sensor
The floor sensor contains a safety extra-low voltage (SELV) circuit, allowing it to be placed as close to the floor surface as possible without having to take account of the risk of shock should the sensor cable become damaged. The two wires connecting the sensor to the mounting box must be additionally insulated, e.g. shrink flex. To prevent loose wires in the fixed installation from coming into contact with the terminal block for the floor sensor, they must be restrained using cable ties. It is strongly recommended that the cable and sensor are placed in a non-conductive installation pipe embedded in the floor. The end of the pipe must be sealed and the pipe placed as high as possible in the concrete layer. Alternatively, the sensor can be embedded directly in the floor. The sensor cable must be led through a separate conduit or segregated from power cables. The floor sensor must be centred between loops of heating cable. The sensor cable may be extended up to 100 m by means of a separate two-core cable. Two vacant wires in a multi-core cable used, for example, to supply current to the floor heating cable must not be used. The switching peaks of such current supply lines may create interference signals that prevent optimum thermostat function. If a shielded cable is used, the shield must not be connected to earth (PE). The two-core cable must be placed in a separate pipe or segregated from power cables in some other way.

Mounting of thermostat with built-in sensor
The room sensor is used for comfort temperature regulation in rooms. The thermostat should be mounted on the wall approx. 1.5 m above the floor in such a way as to allow free air circulation around it. Draughts and direct sunlight or other heat sources must be avoided.

Opening the thermostat

  1. Slide the power button down to Off “0”.
  2. Release the front cover ONLY by inserting a small screwdriver into the slot at the centre of the bottom side of the front cover to press and hold the catch securing the front cover.
  3. Then carefully pull the front cover away, initially from the lower part of the thermostat, then from the upper part of the thermostat.

Connections
Connect the wires in accordance with the diagram. The wires must be connected as follows

  • Term. 1: Neutral (N)
  • Term. 2: Live (L)
  • Term. 3-4: Output, max. 16 A
  • Term. X: Do not connect
  • Term. 5-6: External floor sensor

Mounting the thermostat

  1. Mount the thermostat in the wall socket.
  2. Fit the frame and carefully press the cover onto the thermostat
    1. starting with the upper part of the cover, then the lower part of the cover. Ensure that both the power slide button on the cover and the power switch pin in the thermostat are down.
  3. Click the cover into place by applying light, even pressure.

Warning! Do not apply pressure to the corners of the display cover or to the display itself. DO NOT open the thermostat by releasing the four fixing clips on the back.

Operating the thermostat
There is an ON/OFF switch on the left side of the thermostat: up is ON – down is OFF. The resistive touchscreen requires a soft tap with your fingertip to register the touch.

Installer Wizzard:
The first time the thermostat is connected, push the power slide button to On “I” The Installer Wizard on the touchscreen will guide you through the set up of:

  1. Region
  2. Language
  3. Date
  4. Time
  5. Floor Type

Programming
See user manual

Troubleshooting

If the sensor is disconnected or short-circuited, the heating system is switched off. The sensor can be checked against the resistance table.

Error codes

  • E0: Internal fault. The thermostat must be replaced.
  • E1: Built-in sensor defective or short-circuited. Replace the thermostat, or use the floor sensor only.
  • E2: External sensor disconnected, defective or short-circuited.Reconnect the sensor if disconnected, or replace the sensor.
  • E5: Internal overheating. Inspect the installation

MAINTENANCE

The thermostat is maintenance free. Keep the thermostat’s air vents clean and unobstructed at all times. The thermostat may only be cleaned with a dry cloth.

APPROVALS AND STANDARDS
Regulations OJ Electronics A/S hereby declares that the product is in conformity with the following directives of the European Parliament:

  • LVD – Low Voltage Directive
  • EMC – Electromagnetic Compatibility
  • RoHS – Restriction of the use of certain Hazardous Substances
  • RED – Radio Equipment Directive

Applied standards and approvals
According to the following standard: EN 60730-1, EN 60730-2-9, EN 300 328, EN 301 489-17, EN 301 489-1, EN 62479, EN 50559

Classification
Protection from electric shock must be assured by appropriate installation. Must be installed according to the requirements of Class II (reinforced insulation).

ENVIRONMENT AND RECYCLING
Protect the environment by disposing of the package in compliance with local regulations for waste processing.

Recycling of obsolete appliances
Equipment containing electrical components must not be disposed of along with domestic waste. It must be separately collected together with electrical and electronic waste in accordance with current local regulations.

TECHNICAL SPECIFICATIONS

Purpose of control Electrical underfloor heating
Method of mounting. Wall mounting in a socket or mounting box
Supply voltage 100-240 VAC ±10% 50/60 Hz
Max. pre-fuse 16 A
Built-in interupter 2-pole, 16 A
Enclosure rating IP 21

Wire size, terminals

Current ≤ 13 A – 1.5 mm2, solid core wire

Current > 13 A to 16 A – 2.5 mm2,

solid core wire

ELV limits realized SELV 24 VDC
Output relay Make contact – SPST – NO
Output, load Max. 16 A / 3600 W
Control principle PWM/PI
Standby consumption ≤0.5 W
Battery backup 5 years (storage)
Battery life, typical 5 years (storage) 10 years (powered)
RF frequency band* 2.4 GHz
WIFI* IEEE 802.11 b/g/n – 2.4GHz
Security* WPA/WPA2

Dimensions

OxD5: H/82, W/82, D/40 mm MxD5: H/84, W/84, D/40 mm MxD5-UA: H/115, W/84, D/40 mm
Build-in depth 22mm
Weight ≤200 g
Display 176×220 pixels TFT – resistive touch
Control pollution degree 2
Overvoltage category III
Type of action 1.B
Software class A
Rated impulse voltage 4kV
Ball pressure temperature (TB) 125°C
EU registered design DM/082270

Note: At very low ambient temperatues the display may respond slowly.

Only valid for WiFi Thermostats

DECLARATION OF CONFORMITY

Approval Manager: Palle Jensen of the signatory empowered to bind OJ ELECTRONICS A/S The trademark is registered a©nd 2 b0e2lo2n gOsJ t oE OleJc tErolencitcrosn Aic/sS A/S · © 2022 OJ Electronics A/S

REFERENCE:

DOWNLOAD MANUALS:

OJ ELECTRONICS MWD5-UA Voice Control Wi-Fi Thermostat Installation Instruction

OTHER MANUALS:

OJ ELECTRONICS MWD5-UA Voice Control WiFi Thermostat Product Specifications Guide

OJ ELECTRONICS MWD5-UA Voice Control WiFi Thermostat User Manual

OJ ELECTRONICS MWD5-UA Voice Control Wi-Fi Thermostat Installation Instruction

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago