HONEYWELL THR842D Wireless Room Thermostat
Important notes
- Paper Whiteness & Brightness levels of 90 (+/-5) should try to be achieved where possible. If not possible then notify Resideo of the closest alternative.
- Printing and finishing should be to the best quality achievable by the process and free of blemishes, smudges or other visible defects.
Installation
The THR842D wireless room thermostat comprises a THR842D Room Thermostat and a Relay Box. These devices communicate on an 868MHz Radio Frequency (RF) band to control a single heating system component such as a boiler, pump or zone valve. RF communication is 2-way, allowing high performance energy efficient control, display of boiler information, and easy setup and communications check features.
Relay Box
Installation Notes
- The RF link between the Room Thermostat (THR842D) and the Relay Box in Honeywell system packs is pre-configured at the factory and therefore should be installed at the same site.
- If products from individual system packs are separated, or mixed with other pre-configured system packs during installation, or a faulty unit is being replaced, the desired units must be specially configured to allow them to communicate with each other.
- This process is called Binding. Please refer to section 6) Binding / Rebinding Procedure.
- THR842D or Relay box will not communicate with other RF products that use different frequencies or communications protocols.
- The THR842D room thermostat requires no power source other than the batteries provided.
- The Relay Box requires a permanent 230V~ supply.
- The Relay Box should be installed before commencing the Room Thermostat installation.
Installing the Relay Box
- For best performance, install in an open space. Leave at least 30cm distance from any metal objects including wall boxes and boiler housing.
- Do not mount on metal wall boxes.
- EMC compliance considerations
- Keep AC mains supply/load cables separate from signal wiring.
- Refer to Code of Practice standards EN61000-5-1 and -2 for guidance
Installing the THR842D Room Thermostat
Power up
RF Communication Test
Locating the Room Thermostat
- For best performance, install in an open space where THR842D can sense the room temperature, and where the signal strength is high.
- The Room Thermostat can be mounted on a wall or on the optional table stand.
- Leave at least 30cm distance from any metal objects and at least 1 metre from any other electrical equipment.
- Select the preferred location and test the Signal Strength before installation.
Signal Strength Test
Mounting the Room Thermostat
Test & Binding Flow-chart
Basic System Operation
Automatic Operation
Temporary Manual Override
Loss of RF communications
Installer Mode
To enter Installer Mode
To select a parameter
Display
To change a parameter
To change a parameter
Parameter flowchart
Parameters
Description | Parameter | Range of values | Default Predefiniti |
Minimum ON/OFF time / | Ot | 1,2,3,4,5 m | 1 m |
Cycle rate / Frecuencia de los ciclos / Nombre de cycles/heure / Aantal schakelingen per uur / Zykluszeit / Frequenza dei cicli / Ciklusidő / Počet cyklů / Częstotliwość cykli
/ Počet cyklov / Velocidade de ciclo / Frecvență ciclu / Brzina ciklusa |
Cr | {3,6,9,12} | 6 |
Proportional band width | Pb | 1.5 … 3.0 K | 1.5K
|
Description | Parameter | Range of values | Default |
Temperature measurement offset | tO | -3 … 3 K | 0 K |
Upper setpoint limit | uL | 21 … 35 °C | 35°C |
Lower setpoint limit | LL | 5 … 21 °C | 5°C |
ECO temperature | ES | 5 … 35 °C | 18 °C |
Heat/cool changeover | HC | 0 / 1 | 0 |
0 = Disable | |||
Off setpoint adjust | OS | — (= Off), 5…16°C | 5°C |
Failsafe mode (loss of RF communications) | LC | 0 = Off
1 = On 20% |
0 = Off |
Reset parameters | FS | 0 / 1 | 1 (factory) |
Binding/Rebinding Procedure
The binding operation shown is required if:
- any of the system components (Room Thermostat or Relay Box) are replaced
- Relay Box has incorrect or no binding data stored (for example, when pre-bound system pack components have been mismatched
Reset stored data in Relay Box
Put Relay Box into Binding Mode
Reset stored data in Room Thermostat
Put Room Thermostat into Binding Mode
Bind Room Thermostat to Relay Box
Honey Well
For assistance with this product please visit: livewell.honeywellhome.com