Installing the RF-Switch 16A

Heatmiser-RF-Switch-16A-Wireless-Electric-fig-2

  • Using a small screwdriver, slightly loosen the screw located at the base of the RF-Switch. You can then carefully separate the front panel from the back plate.
  • Mount the RF-Switch back plate on the back box in the wall, fixing into place using the screws provided.
  • Terminate the cables to the RF-Switch as shown in the wiring diagram (section 6).
  • Mount the front panel onto the back plate, tighten the retaining screw on the base.
  • Switch on the power supply, the power LED will illuminate.

Overriding the RF-Switch 16A output

  • To override the output on the RF-Switch, simply press the override button once, the output & LED will be activated.
  • To override the output off, press the button once again. The output & LED will turn off.

Pairing the RF-Switch 16A

  • On the RF-Switch, press and hold the pairing button for 3 seconds.
  • The pairing/override LED will flash to indicate pairing mode is active.
  • The pairing method of your wireless thermostat will differ depending on the model.
  • Please refer to the instruction manual of your wireless thermostat on how to complete the pairing procedure

Factory Resetting the RF-Switch 16A

  • To reset the RF-Switch, follow these steps;
  • Press and hold the pairing/override button for 10 seconds.
  • During this time the LED on the RF-Switch will flash, then after 10 seconds stay permanently solid.
  • Release the button, the reset procedure is complete

Diagram

RF-Switch 16A Wiring Diagram

Reference

Download manual:

Heatmisser RF-Switch 16A Wireless Electric THERMOSTAT INSTALLATION GUIDE

Heatmiser-logo

Heatmisser RF-Switch 16A Wireless Electric THERMOSTAT INSTALLATION GUIDE

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)