Heatit Z-TRM3 is an electronic thermostat for electrical underfloor heating, designed to be mounted in a standard flush box. The thermostat has a built-in Z-Wave chip that can be connected with  Home Automation systems. Heatit Z-TRM3 has SmartStart. Heatit Z-TRM3 is equipped with a single pole relay and fits into System 55 frames.
The thermostat can withstand a load of max 16A/3600W at 230VAC. We recommend a contractor for loads above 13A. The thermostat may be connected to two wired external sensors. The thermostat has the capacity of up to 5 associations (relays, wall plugs, etc.).
NB! If the sensor mode is changed to A or AF mode, then a room sensor compensation process will start, which limits maximum power output to 75%. The thermostat adapts to the environment within a few days. No internal sensor calibration should be performed during the first few days.
STATEMENT REGARDING PRODUCTS FROM MULTIPLE MANUFACTURERS

Please read this before the installation
This device may be used with all devices certified with the Z-Wave Plus™ certificate and should be compatible with such devices produced by any manufacturer. Every primary controller is different depending on the manufacturer, their target audience and intended use/application. Please review the functionalities implemented by the primary controller you intend to o use with our Z-Wave Plus certified device to ensure that it provides the necessary controls to take full advantage of our product’s capabilities.

INSTALLATION

Installation must be done by a qualified electrician in accordance with the National Building codes. Before installation, disconnect the power to the device from the mains. During installation of the device, power to the device must be disconnected AT ALL TIMES! Use e.g. a small slotted screwdriver. Start by carefully removing the front cover by pushing the release springs. The front cover and the frame may now be removed.

Connect the wires to the thermostat terminals: Use 1.5mm² or 2.5mm² according to load.

  • HEATING (N) Heating cable connection (Neutral)
  • N Power connection (Neutral) 230VAC
  • L Power connection (Live) 230VAC
  • HEATING (L) Heating cable connection
  • FLOOR SENSOR NTC type (10, 12, 15, 22, 33 or 47kΩ). Default 10kΩ.
  • EXTERNAL SENSOR NTC type (10, 12, 15, 22, 33 or 47kΩ). Default 10kΩ.

Next, position the thermostat and fasten it onto the wall mounting box using 2-4 screws. Position the frame over the flush box, then position and carefully press the front cover until it snaps in place. Check that the front cover has snapped in place properly on both left and right sides. The front cover should now fir firmly on both sides. To be able to to read the Power Metering, the load needs to be connected to both heating L + N.
Note! The top cover has to be installed when the thermostat is connected to the main power source. The thermostat is not a SELV product. All voltage parts must be considered to be 230VAC.

ADD/REMOVE

  1. Press Center (confirm) for 10 seconds. The display will show OFF.
  2. Press Right (down) 5 times until you see Con in the display.
  3. Start the add/remove device process in your primary controller.
  4. Start to add/remove mode by pressing Center (confirm) for approximately 2 seconds.

Adding/removing mode is indicated on the display by rotating LED segments on the display. This lasts until the timeout occurs after 90 seconds, or until the module has been added/removed in the network. Confirmation will show Inc/EcL on the display. Exit the programming mode by choosing ESC in the menu. Your thermostat is now ready for use with default settings.

TECHNICAL DATA

  • Protocol Z-Wave – 868.4MHz
  • Chip Z-Wave 500 chip
  • Rated voltage 230VAC 50/60Hz Max load 3600W (resistive loads only)
  • Recommends contactor for loads higher than 13A
  • Max current 16A
  • Power consumption <2,0W
  • Ambient temperature 2°C to 40° (during operation)
  • Temperature range 5°C to 40°C
  • Hysteresis 0.3°C to 3.0°C (default 0.5°C)
  • Compatible with NTC
  • sensors with values 10, 12, 15, 22, 33 og 47 kΩ @ 25°C
  • IP Code IP 21
  • Approvals Z-Wave Plus, CE, EN 60730-1 EN 60730-2-9 EMC 2014/30/EU RoHS 2011/65/EU LVD 2014/35/EU
    Approved for use in bathrooms.

Heatit Controls AB can not be held liable for typographical errors, other errors, or omittances in our information. Product specifications may change without further notice.
All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.
Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Phone: +47 61 18 77 77
[email protected]
www.heatit.com

Reference

Download Manual:

Heatit Z-TRM3 Z-Wave Thermostat Quick Start Guide

OTHER MANUALS:

Heatit Z-TRM3 Thermostat Z-Wave Product Specifications Guide

Heatit Z-TRM3 thermostat Z-Wave Installational Manual

heatit-logo

Heatit Z-TRM3 Z-Wave Thermostat Quick Start Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)