BEOK TGR87 Round Touch Screen Thermostat
Product Summary
TGR87WIFI series Heating Thermostat is a WIFI touch screen thermostat with smartphone control. It’s a round curved screen. It is applied to temperature control of the industrial, commercial and domestic room, and start of control heating appliances, especially floor heating systems. It can be controlled by phone. Phone systems are IOS and Andriod system optional.
Technical Parameter
Power Supply | 200 ~ 240V 50 ~60Hz |
Current Load | ≤3A(water heating)≤16A(electric heating) |
Power Consumption | <0.3W |
External Material | PC+ABS (flame retardant) |
Sensing Element | NTC; floor sensor 10K 3950 |
Set Temp. Range | 5-60℃ |
Floor Set Temp. Range | 5-99℃ |
Accuracy | ±1℃( 0.5 adjustable) |
Dimension | 86x86x13.3mm |
Ambient Temp. | 0-45℃,5-95%RH(Non-condensing) |
Storage Temp. | -5~55℃ |
Timing Error | <1% |
Main Functions and Characteristics
- Round curved screen.
- WIFI for Andriod & Apple iOS.
- Large screen display and touch button.
- Power-off memory function.
- Real-time data save function.
- 5+2 or 6+1or 7days six periods program schedule.
- Anti-freezing function.
- 3 sensor modes can be setting.
- With child lock function.
- Selectable 80mmx80mm European hidden box.
User Interface Explanation
Model Spec
Week Program | Controlled Objects |
TGR87WIFI-EP 16A | For electric heating appliances |
TGR87WIFI-WP 3A | For water heating appliances |
TGR87WIFI-WPB 3A | For gas boiler |
Wiring Diagram
Thermostat Operation Instruction
Setting Power on/off
Press to turn on/off the power.
Setting Temperature
Press to set the temperature.
Setting the Clock
Press to set minute, hour and week. Press for adjusting.
Setting the Manual Mode.
Manual mode means non-programmable mode. Press then will display in t he screen, it is in manual mode. Press to set the temperature. Press to set the minute, hour and week.
Setting the Child Lock
Long press to enter into child lock mode, will display. Long press again, the child lock will be disappeared.
Setting the Programmable Mode.
Press and hold into programmable mode. LOOP and 12345 will display. Press to select the control way: 5+2 or 6+1 or 7 days programmable. 12345 display in the position of week means 5+2; 123456 display in the position of week means 6+1;
1234567 display in the position of week means 7 days programmable. Press to select the periods. Press to change the temperature; Press to do time adjustment. Press to change the time; Press again to select the weekend’s temp. If you want to make a temporary adjustment in any period, press then will flash. When finish the setting, all will confirm automatically. Press to switch operation between manual mode and programmable mode.
Period | Period Icon | Defaulted Time | Defaulted Temp. | |
Week |
1 | 6:00 | 20℃ | |
2 | 8:00 | 15℃ | ||
3 | 11:30 | 15℃ | ||
4 | 12:30 | 15℃ | ||
5 | 17:30 | 22℃ | ||
6 | 22:00 | 15℃ | ||
Weekend | 1 | 8:00 | 22℃ | |
2 | 23:00 | 15℃ |
Remark:
- The defaulted temperature of period3 and period4 is the same as period2. Please change it according to the request.
- When setting temperature is 00, this period is powered off.
- How to check floor temp? During power-on, press and hold then press the button of power to check floor temp.. OUT TEMP will display. Press again to display room temp.
Advanced Setting
In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item.
Display Code | Function | Setting And Options | Factory Defult |
SEN | Sensor mode | 0:Internal sensor 1:Floor sensor2:Both internal sensor and floor sensor | 0 |
OSV | Set temp. rangefor floor sensor | 5-99℃ | 42℃ |
DIF | Precision for floor temp. | 1-9℃ | 2℃ |
SVH | High limit temp. for internal sensor | 5-99℃ | 35℃ |
SVL | Low limit temp.for internal sensor | 5-99℃ | 5℃ |
ADJ | Measure temp. | Check and calibrate the actual room temp. | 0.5℃accurac calibrate |
FRE | Anti-frozen | 00:Close anti-frozen01:Open anti-frozen | 00 |
PON | Power memory | 00:Power memory off 01:Power memory on | 00 |
DFI | Precision for room temp. | 0.5~3℃ | 1℃ |
FAC | Factory setting | 10 or 32:Wifi mode open08:Just display | 08 |
Remark:
DIF: Precision for floor temp. i.e. the setting deadzone for floor sensor is 2, OSV is 42℃ when actual temp. reach 44℃, the relay will stop working; when actual temp. is back to 40℃, the relay starts working again. It works when room temp. is lower than set temp.
DFI: Precison for room temp. The factory default is 1℃,if you think 1℃ is too big, you could change to 0.5℃
Sensor error:
Please select the right sensor mode. If Err display on the screen, change SEN=00 Or connect the floor sensor.
Phone Port Operation Instruction
Install APP on phone
For iOS system: Login in App Store, search “ Beok Home”, you can download it on your iPhone. Or scan the below code to download: For Android System: Login in to Google Play, and search “Beok Home”, you can download it on your phone.
Or scan below code to download:
Connection Thermostat with Phone
Thermostat Setting
- In the power state, hold on Clock key, then press the Power key.
- Go into Advanced Setting, press the Menu key 9 times until FAC mode appears.
- When FAC appears, press UP key to change from 08 to 10 or 32.
- Then, press power off.
- In the power-off state, hold on Clock key, then press the Power key again.
- At this time, the wifi symbol will be twinkling quickly and frequently. It means you can connect the thermostat with your phone now. When wifi symbol stop twinkling, it means the thermostat is successfully connected with phone.
Connection with Phone - Open Book Home APP on your phone, you can see APP welcome page
Phone part - When the thermostat Wifi Symbol twinkles fast, you can start the configuration on your Phone.
- Enter your wifi name and password, then start connection a t below. When connection success, it will appear “Connection Success”.
- After connection success, you need to press the “Search “ key.
- Then it will appear your wifi thermostat HVAC. HVAC is the factory setting name, when you have more than 2 thermostats, you can change it to any name you want.
- Long press HVAC for 5 seconds, it will appear Edit Thermostat page. Press Modify Current Thermostat. You can change HVAC to room 1, Bedroom Bath room, or anything you like.
APP Interface on the Phone
Thermostat Setting through Phone Operation
- Clock : You can press Time Matching switch to match your phone clock with the thermostat clock.
- Children lock (screen locking): Press to lock the thermostat.
- Anti-Freezing: Press thermostat will show means Anti-freezing function open.
- Temperature setting: You can directly drag the pointe Temperature Setting Dial to set temperature. Or press and temperature step.
- Period setting: Long press Period Display, you will go into the Period Setting mode:
- Advanced Setting: Long Press Senior setting mode:
- Switch of Manual mode and Auto mode: Press mode or Auto mode.
- Power off : Press to turn on or off the thermostat.
Display Code | Function | Setting And Options | Factory Defult |
SEN | Sensor mode | In-s control Out-s controlIn-s control., Out-s limit | In-s control |
OSV | Floor set temp. range | 5-99℃ | 42℃ |
DIF | Floor temp. ctrl diff | 1-9℃ | 2℃ |
SVH | Room temp set max | 5-99℃ | 35℃ |
SVL | Room temp set min | 5-99℃ | 5℃ |
ADJ | Room temp. adjust | -5-5℃ | 0℃ |
FRE | Anti-frozen | close/open | Close |
PON | Power memory | off/on | On |
Attention to Phone WiFi Connection
- After you press Configure, if the connection fails:
Please confirm your mobile phone is set to WLAN mode, and ensure its (mobile data)3g/4g is turned off. Please connect to 2.4G wifi, not 5G wifi. Please add your wifi router name, we recommend it does not include spaces or Chinese symbols.
Please check your wifi router password. We recommend not over 32 characters, no spaces, no blank password, no special symbols except letters and numbers. Please check module is successfully reset . In the power-off state, press the Time key first, then press Power key to enter Advanced Setting. Find FAC mode, to change FAC to 10 or 32, then turn the thermostat off Press Time key within 2 minutes, then press Power key again. This time, it will not enter Advanced Setting, but the WIFI symbol on the LCD screen will be flashing quickly and frequently. This means wifi module has been reset successfully. Then wait for APP to connect well. Please confirm wifi password is correctly filled. We recommend you check the password to be visible when it is input. - If it displays the following reminder, please go to Advanced Setting to reset the corresponding setting.
Installation Instruction
This product is suitable for standard 80*80mm wall box and 60 mm European round boxes. This thermostat is suitable for standard 80*80mm wall box Or 60*60 mm Europe standard round box.
- 1. Turn off the main power Take away the front display screen part, then use a screwdriver to open the installation panel.
- Refer the wiring diagram(VII) to connect the lines with terminals. Fix the installation panel with installation box with screws, and insert it into wall
- Insert the display screen part into the installation panel.
- Installation finished.
NOTICE: The installation wire should be 1.5-2.5mm2.
Thank you for buying this product!
Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.
In the box you will find
Model | TGR87WIFI-EP | TGR87WIFI-WP | TGR87WIFI-WP |
Thermostat | √ | √ | √ |
User Manual | √ | √ | √ |
Screws | √ | √ | √ |
External sensor | √ |
Our Service
We offer a warranty of 24 months from the sales day. During the warranty, if it belongs to a quality issue, we will fix or replace them for you by free after testing them. If it is not a quality problem or beyond the warranty time, we will charge for the after-sales service.
Warning:
The symbol means the unit is being installed, it may cause electrical shock hazards during maintenance, so please make sure it is operated by a professional technical worker.
REFERENCE
Download Manual
BEOK TGR87 WiFi Round Touch Screen Thermostat Instruction Manual
Leave a Reply