BEOK- BOT-R315- RF- GasBolier -Programmable- Thermostat- featured

BEOK BOT-R315 RF GasBolier Programmable Thermostat Instruction Manual

logo - Copy - Copy

BEOK BOT-R315 RF GasBolier Programmable Thermostat

BEOK- BOT-R315- RF -GasBolier- Programmable- Thermostat-pro

Specification

  • LCD Size: Diameter 55mm
  • Power Supply: R315 3V DC (2 x AAA 1.5 V)
  • RCV315 22V ac, 50/60Hz
  • Current Load: 10A (Resistive)
  • Ambient Temp. Range: 0~99.5 ℃
  • Setpoint Range: 5~35 ℃
  • Accuracy/Tolerance : +/ -0.5℃
  • Timing Tolerance : <1%
  • Thermistor : 10KΩ@25 ℃
  • Storage Conditions Temp.: -10~60 ℃
  • Humidity:< 90% r.h.
  • Battery Life: 6 months
  • RF Module: Single Way Module
  • Frequency: 433 Hz(defaulted

Display & Buttons

  1. BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 1Week day: from Monday to Sunday
  2. Programmable Time Zone
  3. Room Temperature
  4. Buttons Lock
  5. Setpoint,or Floor Temperature(It displays when external sensor activated)
  6. Time of day(00:00..23:59)
  7. Heating is on
  8. Automatic Programmable Mode: 7 days, 6 time zones
  9. Comfort Mode
  10. Energy Saving Mode
  11. Holiday Mode
  12. Batteries Comsumption Indicator
  13. Manual Mode(overriden)

Working Modes selecting .

  • Press BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 2shortly to select Comfort Mode, Energy Saving Mod, Holiday Mode, Automatic Mode, and Manual Mode(Overridden Mode)
  • Synchronizing Clock
  • Press BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 3button to switch off thermostat, and then press and hold M b utton fo r 3 s ecs, a djust c lock fr om M inute, Second and Weekday via BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 4.
  • There are 4 Time Zones in total, user is able to customize Time Zones from 1 to 4 according to their demand. Press and holdBEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 6 button for 3 seconds , it will display 4 and Monday, adjust the numbers(1 to 4) of Time Zones via . BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 4Press BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 2shortly to enter into Automatic Mode Settings of each Time Period and relative Setpoint. Sequence is from Hour (1 st time zone), Minute(1st time zone) and Setpoint(1 st time zone) to Hour (4 thtime zone), Minute(4th time zone) and BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 2Setpoint(4 th time zone).
  • After Settings of Monday is done, pressBEOK-BOT-R315 RF-GasBolier-Programmable-Thermostat-fig-6 shortly and switchover from Tuesday to Sunday, follow the same setting steps as above.BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 8

Ex-factory Setting

BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 9

  • BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 10Temperature up, or other parameters setting In case of internal and external sensors are selected,
  • press button BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 9for 3 sec, Setpoint is displaying external sensor’s temperature; after 3 sec, it returns to setpoint.
  • BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 5Menu
  • Temperature down, or other parameters setting
  • BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 7 On/off button

Parameters Setting
Press BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 7button to switch off the and then press and hold BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 4button for 3 second.

  • D1 Diff. Temp of Switch On/ Switch off :
  • from 0.2 ℃ ~ 2.0℃ , select by buttons .
  • D2 Temperature Calibration:
  • -4 ℃ to + 4 ℃, select by buttons .
  • D3 Frost Protection:
  • 5 ℃ to 15 ℃, select by buttons

Settings

RF IP Learning: Transmitter and Receiver is well-paired ex-factory. If new learning is required. Please follow the steps below:

  1. Press and hold the RF Connectionbuttonon receiveruntilLED 2(refer to below photo) is flashingin green rapidly.
  2. Switch off the thermostat, and press and hold the thermostats / OFF button for 3 seconds until the menu setting appears.
  3. Switch to the d6 settings via ON/OFF button, and then press on the thermostat to confirm the connection. Switch on the thermostat, and the green LED 2 (refer to the below photo) on the receiverwillturnoff completely.BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 9

Child Lock/Unlock

  • Push and hold and buttons simultaneously for 5 sec to LOCK all buttons
  • Push and hold and buttons simultaneously for 5sec to UNLOCK all buttons

Wiring Diagram

BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 12

Dimension

BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 13

Replacement of Batteries

If the battery BEOK- BOT-R315- RF- GasBolier- Programmable -Thermostat- fig- 14symbol appears, the batteries are almost exhausted and must be replaced

Warranty

We offer warranty of 12 month, from the sales date. If it is not the quality problems, or beyond the warranty period, we will charge for the aft-ersales services

REFERENCE

DOWNLOAD MANUAL

BEOK BOT-R315 RF GasBolier Programmable Thermostat Instruction Manual

 

logo - Copy - Copy

BEOK BOT-R315 RF GasBolier Programmable Thermostat Instruction Manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)