CTC-LOGO

CTC 43153 PROGRAMMABLE THERMOSTAT 

CTC-43153-PROGRAMMABLE-THERMOSTAT-PRODUCT

Congratulations!
Your new Climate Technology thermostat will provide years of reliable service. By saving energy, your thermostat will pay for itself during its first season of use. Thank you for buying a Hunter product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Climate Technology Technical Support at 1-800-676-7861 from 8 am to 5 pm Central Time.
Ask Your Local Retailer for Other Quality Products from CTC

CTC-43153-PROGRAMMABLE-THERMOSTAT-FIG.1

IMPORTANT INFORMATION

  1. This thermostat is designed to work on the following systems:
    • Gas – Standing Pilot Electric Furnace
    • Gas – Electronic Ignition Electric Air Conditioning
    • Gas – Fired Boilers
    • Gas – Milivolt Systems
    • Oil-Fired Boilers This thermostat will NOT control single-stage or multi-stage
    • Oil – Fired Furnace heat pumps or 110/220 V baseboard electric heating systems.
  2. Temperature Range
    This thermostat can be programmed between 45°F and 95°F (7°C and 35°C). However, it will display room temperatures from 30°F to 99°F (0°C and 37°C). “HI” will be displayed if the temperature is higher than 99°F (37°C), and “LO” will be displayed if the temperature is lower than 30°F (0°C). This thermostat will automatically cut off in Heat mode if the temperature rises above 95°F (35°C), and automatically cut off in Cool mode if the temperature drops below 45°F (7°C).
  3. Compressor Protection
    This thermostat provides a 3.5-minute delay after shutting off the cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. It does not prevent a rapid compressor restart due to short power outages.
  4. Battery Warning
    Two fresh AA alkaline batteries should provide well over one year of service. However, when the batteries become drained, the Low Battery Indicator will flash on the display. When this message occurs, install new alkaline batteries. You have approximately 1 minute to change the batteries and keep the thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for flashing Low Battery Indicator on the LCD display.
    CAUTION: When ONLY the battery icon flashes on the display, the thermostat is shut down, and your system will no longer operate. In this condition, there is no temperature control in your dwelling.
    NOTE: The INDIGLO® night light will not function when the thermostat is in low battery condition.
    NOTE: If you plan to be away from the premises for over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving.

FEATURES

CTC-43153-PROGRAMMABLE-THERMOSTAT-FIG.2

INSTALLATION

What You Need
This thermostat includes two #8 slotted screws and two wall anchors for mounting.
To install your thermostat, you should have the following tools and materials.

Remove Old Thermostat
CAUTION: Do not remove any wiring from the existing thermostat before reading the instructions carefully. Wires must be labeled prior to removal.

Typical Home Thermostats

CTC-43153-PROGRAMMABLE-THERMOSTAT-FIG.3

Wire Labeling

NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non-battery-powered thermostats.
Mount Wallplate and Thermostat

NOTE: 5-wire Systems
If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.

Connect Wires and Mount Thermostat to Wallplate

Wiring Diagrams

CTC-43153-PROGRAMMABLE-THERMOSTAT-FIG.9 CTC-43153-PROGRAMMABLE-THERMOSTAT-FIG.10

Selector Switches
In order for this thermostat to control your system, the system type must be specified by the selector switches on the printed circuit board inside the thermostat. There is also a selector switch for your choice of Fahrenheit or Celsius temperature display.

OPERATION

Setting Day and Time

Refer to the Steps below

12 Hr. / 24 Hr. Time Format
Your thermostat is set from the factory in the normal 12 (AM / PM) time format. To change to 24-hour (military) time, press at any time while the Hour, Minute, or Day is flashing to toggle between the 12-hour and 24-hour formats. The AM / PM indicator will not be displayed in 24-hour mode. Both the current time and all programs will automatically change to the selected format.

PROGRAMMING

The following time and temperature settings are pre-programmed into the thermostat:

Temperature in F° (C°)
Program Number Time Heat Cool
1 6:00 am 68°F (20°C) 78°F (26°C)
2 8:00 am 60°F (16°C) 85°F (29°C)
3 4:00 pm 68°F (20°C) 78°F (26°C)
4 10:00 pm 60°F (16°C) 82°F (28°C)

All 7 days of the week have the same default programs.
Personal Program Schedule
You can revise the factory programs to match your own schedule. Use this Personal Program Schedule to determine which times and temperature settingsmatch your comfort and energy saving requirements. Use a pencil so you can revise your records each time you change your program settings.
Heating

Monday –        Time Friday

Temp

Time

Temp

Time

Temp

Time

Temp

Saturday –        Time Time Time Time
Sunday

Temp

Temp Temp Temp

COOLING

Day Program 1 Program 2 Program 3 Program 4
Monday – Friday Time

Temp

Time

Temp

Time

Temp

Time

Temp

Saturday – Sunday Time

Temp

Time

Temp

Time

Temp

Time

Temp

Revising Programs

NOTE:

  1. STEP 1:
    Slide the System Switch to the HEAT or COOL position to program the corresponding system.
    NOTE: If the System Switch is in the OFF position, the last position used will be programmed.
  2. STEP 2:
    Press to enter program mode. HEAT or COOL will be displayed on the LCD
  3. STEP 3:
    The Program hour and AM or PM indicators are flashing. Press to change the hour.
  4. STEP 4:
    1. Press again to change to the minute position. The current minute will be flashing.
    2. Press to change the minute.
  5. STEP 5:
    • Press again to change the program temperature. The current temperature will be flashing.
    • Press to change the temperature.
  6. STEP 6:
    • Press again to move to the next program number.
    • Repeat Steps 3 through 5 to change the remaining Weekday and Weekend programs. (There are a total of 8 programs.)
    • After cycling through all 8 programs, press again to return the display to normal.
    • Press at any time to exit the Program Mode.

Reviewing Programs
To review your program settings, press repeatedly to cycle through the programs. You can also make changes at any time.
System Selector Switch
The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. You may select COOL, OFF, or HEAT.
NOTE: Anytime you install or remove the thermostat from the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off.
Fan Switch
The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with the normal operation of your system. In a normal gas or oil furnace, the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on with the system. To run the Fan on continuously, slide the Fan switch to the ON position.
Temporary Manual Override

Permanent Override
To hold your Manual Override for vacation or just an extended period of time:

SPAN Setting Mode
Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time.

The Span settings remain the same for both HEAT and COOL. The Span can be changed at any time, and is independent of program times or temperatures.
When batteries are installed in the thermostat, or the Reset key is pressed, the Span is reset back to setting 2.

Backlighting (INDIGLO® Night-Light)
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark.
When any key is pressed or the System Switch is changed, the display is illuminated. The display will remain illuminated for 5 seconds after the last key is pressed. This allows the light to stay on if you need to operate several keys.
Note: If the thermostat is in Low Battery warning condition, the backlight will not operate. Replace with 2 new AA alkaline batteries to restore the Backlight function.
Low Battery Warning
Your thermostat has a two-stage low battery warning system. When the batteries are first detected to be weak, the first stage low battery warning is indicated by the battery symbol flashing on the LCD display. At your earliest convenience, you need to replace the batteries with 2 new alkaline batteries.
When the batteries become too weak for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, “BATT” flashes alone on the display, and the thermostat will turn your system Off. Your system will remain shut off until the batteries are replaced.
Note: The thermostat will still keep the current time and your programs in memory until new batteries are installed. After confirming that new batteries have been inserted, the thermostat will return to normal operation.
Error Mode
If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes “Err” on the LCD display, and shuts off your system. To correct this problem, replace the batteries with 2 new AA alkaline batteries, even if you have recently replaced them. Next, use a paper clip to press the RESET button next to the keypad. You will need to reprogram your thermostat and confirm normal operation. If Error Mode returns, please call CTC Technical support at 1-800-676-7861 for further information.
Auto Cut Off
Your thermostat will automatically cut off in Heat mode if the room temperature rises above 95°F (35°C). It will cut off in Cool mode if the room temperature drops below 45°F (7°C). Note that if your system has malfunctioned and no longer responds to thermostat controls, the Auto Cut-Off will have no effect.
Mechanical Heat Back-up
This thermostat includes a bi-metal switch that will automatically turn on the Heat when the temperature reaches about 41° F (5° C). WARNING: This switch only activates the Heating terminal (W). The system itself must be capable of automatically turning the Fan On. Without normal Fan operation, severe damage to the heating system could result.

TROUBLESHOOTING

Problem Solution

Erratic Display
If the unit continues to operate in the Off position
The thermostat permanently reads “HI”, “LO”, or “ERR”
If you experience any other problems, call 1-800-676-7861 from 8 AM to 5 PM Central Time for technical assistance.

REFERENCE:

DOWNLOAD MANUALS:

CTC 43153 PROGRAMMABLE THERMOSTAT Owners Manual

CTC-LOGO

CTC 43153 PROGRAMMABLE THERMOSTAT Owners Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)