COMPUTHERM-logo

COMPUTHERM Q20 Programmable Digital Room Thermostat

COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (2)

A GENERAL DESCRIPTION OF THE THERMOSTAT

IMPORTANT WARNINGS AND SAFETY RECOMMENDATIONS

INFORMATION APPEARING ON THE DISPLAY OF THE THERMOSTAT

COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (4)

LOCATION OF THE THERMOSTAT

It is reasonable to locate it in a room used regularly or for many hours per day so that it is in the direction of natural ventilation in the room but protected from drought or extreme heat (e.g. direct sunlight, refrigerator, chimney, etc). Its optimal location is 0.75 – 1.5 m above floor level.

IMPORTANT WARNING! If the radiator valves in your flat are equipped with a thermostatic head, adjust it to maximum temperature or replace the thermostatic head of the radiator valve with a manual control knob in the room where the room thermostat is to be located, otherwise, the thermostatic head may disturb the temperature control of the flat

PUTTING THE THERMOSTAT INTO OPERATION, BASIC SETTINGS

Connection of the thermostat
WARNING! The device must be installed and connected by a qualified professional. Before installing, make sure that neither the thermostat or the device to be controlled is connected to the 230 V mains voltage

Modifying the thermostat can cause electric shock or product failure

ATTENTION! Always consider the load ability of the receiver unit and follow the manufacturer’s instructions for the heating or cooling equipment. The device must be installed and connected by a qualified professional! The voltage appearing at terminals 1 (NO) and 2 (COM) depends only on the system being controlled, therefore the dimensions of the wire are determined by the type of the device to be controlled. The length of the wire is of no significance.

Commissioning the thermostat

OPERATION OF THE THERMOSTAT THAT HAS BEEN PUT INTO OPERATION

SETTINGS

ATTENTION! According to factory default setting the key lock of the thermostat automatically switches on after 30 seconds which is indicated by theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (13) icon that appears in the bottom right corner of the display. To unlock theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (13) keyboard, touch the button for 2 seconds COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (13) until the icon disappears from the display.

 

Displayed

abbreviation

 

Description of the setting

 

Setting options

 

Factory default setting

 

Detailed

description

 

 

FUNC

 

 

Operating mode

HEA: heating  

 

HEA

 

 

Chapter 7.1.

COO: cooling
HUM: humidifying
DEH: dehumidifying
 

 

 

PROGRAM

 

 

Switching on and off

of programmed mode

OFF: Switched off. In this case the thermostat is working in a manually set Economy mode or comfort mode.  

 

 

ON

 

 

 

Chapter 7.2.

ON: Switched on. In this case the thermostat is working according to a pre-set program or manual mode.
 

T UNIT

 

Temperature unit

°C  

°C

 

°F
 

HYSTER

 

Switching sensitivity

±0.1 – ±1.0 °C ±0.2 °C  

Chapter 7.3.

±0.2 – ±2.0 °F ±0.4 °F
±1 – ±5% RH ±1% RH
 

MIN

 

Minimum adjustable temperature/ humidity

5 – 45 °C 5 °C  

41 – 97 °F 41 °F
0 – 98% RH 30% RH
 

MAX

 

Maximum adjustable temperature/

humidity

5 – 45 °C 35 °C  

41 – 97 °F 95 °F
1 – 99% RH 80% RH
Displayed

abbreviation

Description of the setting Setting options Factory default setting Detailed

description

 

T CALIB

 

Calibration of the temperature sensor

-3.0 – +3.0 °C 0.0 °C  

Chapter 7.4.

-6.0 – +6.0 °F 0.0 °F
H CALIB Calibration of the humidity sensor -10 – +10% RH 0% RH Chapter 7.5.
 

 

 

H LIMIT

 

 

Setting humidity limit

in case of cooling

 

OFF: function switched off

 

 

 

80% RH

 

 

 

Chapter 7.6

30-99: if the measured humidity is higher than the set value then the cooling system switches off
 

 

 

A LIGHT

 

 

 

Automatic backlight

 

OFF: switched off

 

 

 

ON

 

 

 

ON: switched on (backlight switches on for 10

seconds after any button has been pressed)

BRIGHT Backlight brightness 0 – 10 7
 

 

 

B LIGHT

 

 

 

Backlight of the buttons

 

OFF: switched off

 

 

 

ON

 

 

 

ON: switched on (backlight of the keys switches on and off simultaneously with the backlight of the display)
Displayed

abbreviation

Description of the setting Setting options Factory default setting Detailed

description

 

B SOUND

Acoustic signal when buttons are touched OFF: switched off  

OFF

 

ON: switched on
 

 

 

LOCK

 

 

 

Automatic key lock

 

OFF: automatic key lock is switched off

 

 

 

ON

 

 

 

ON: automatic key lock is switched on (the key lock is activated 30 seconds after touching the last button)
 

PUMP

Switching on and off of the pump

protection function

OFF: switched off  

OFF

 

Chapter 7.7.

ON: switched on
 

 

 

RESET

 

 

 

Restoring factory default settings

–: saving the settings and exiting the settings menu after touching

the  button

 

 

 

 

 

 

Chapter 7.8.

RES: restoring factory default setting after

touching  button

To exit the setting menu and save the settings:

Selecting the operating mode (FUNC)

You can easily switch between heating (HEA; factory default setting), cooling (COO), humidifying (HUM) and dehumidifying (DEH) modes. The connection points of the output relay of the receiver unit 1 (NO) and 2 (COM) close at temperatures below those set in the heating mode, at temperatures above those set in the cooling mode, below the humidity level set in the humidifying mode and above the humidity level set in the dehumidifying mode (taking the switching sensitivities into account).

Switching on and off of the programmed mode (PROGRAM)

Selecting switching sensitivity (HYSTER)

Calibration of the temperature sensor (T CALIB)

The accuracy of the thermometer of the thermostat is ±0,5 °C. The temperature displayed by the thermostat can be modified by a maximum ±3.0 °C / ±6,0 °F compared to the temperature measured by the temperature sensor, in increments of ±3.0 °C / ±6.0 °F or 0.1 °C / 0.1 °F.

Calibration of the humidity sensor (H CALIB)

The accuracy of the humidity sensor of the thermostat is ±3% RH.
The relative humidity displayed by the thermostat can be modified by a maximum of ±10% compared to the humidity measured by the sensor, in increments of 1%.

Setting the humidity limit for cooling (H LIMIT)
When a cooling system including surface cooling is controlled, it is important that the air in the room must not reach a dew point because in this case, condensation occurs which can cause serious damage. Using this function you can set the humidity level above which the thermostat will stop cooling to prevent condensation

Switching on and off of the pump protecting function (PUMP)

In order to prevent the pump from jamming, the activated pump protection function will start the devices connected thereto for 1 minute every day at 12:00 p.m. (noon), if switching was not done either on a respective day or on the previous day (e.g. during the non-heating period). The pump protection function only works when the controlled device is in operable condition.

Restoring factory default setting (RESET)
This function resets all settings of the thermostat to factory default. To restore the factory default setting choose the option “RES” at the “RESET” function in the setting menu and move on with theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (14) button.
Leaving the “RESET” function in the default state (COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (17) ) after touching theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (14) button the thermostat saves the settings, exits this menu, and after returning to the home screen continues its operation according to the operating mode set beforehand.

OPERATING MODES OF THE DEVICE

The thermostat has the following four operating modes:

Touching theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (14) button you can switch between the modes.
When you intend to operate your device temporarily in a way other than the set default mode (e.g. on the occasion of a family gathering, a holiday or a winter vacation) then you can choose from the following 3 supplementary operating modes:

The thermostat can be used for control on the basis of temperature and humidity alike. In every mode, the temperature/humidity to be maintained by the thermostat can be defined in 0.5 °C / 0.5 °F / 1% increments within the intervals specified in the settings

Economy mode (COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (18) )

In economy mode the thermostat provides the economical (e.g. nighttime) temperature/humidity corresponding to the set temperature/humidity in the vicinity of the place of installation. Using theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (15) and COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (16)buttons these values can be modified at any time while this operating mode is used.

Comfort mode (COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (19) )

In comfort mode the thermostat provides the comfort (e.g. daytime) temperature/humidity corresponding to the set temperature/humidity in the vicinity of the place of installation. Using theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (15) andCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (16) buttons these values can be modified at any time while this operating mode is used.

Manual mode (COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (20) )
In manual mode the thermostat provides the temperature/humidity corresponding to the set temperature/humidity in the vicinity of the place of installation until the next intervention. UsingCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (15) andCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (16) buttons these values can be modified at any time while this operating mode is used.

Programmed mode (COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (21) )

Steps of programming the device

If you would like to copy the program written for the day selected in section “b” to another day/other days you can easily do it by means of the “COPY” function as described in Chapter 8.4.3.

The use of “COPY” function (copying the program of a day to another day or other days)
Attention! The “COPY” function may only be used for programming the days of the week separately!
Touch theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (8) button to move the display of the thermostat to the home screen then enter the programming menu by touching theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (21) button for 2 seconds.
Following this, touch theCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (14) button for 2 seconds to activate the “COPY” function. The state of being ready for copying the program is indicated by the “ ” notice appearing in the place of hour characters and flashing of the syllable showing the day being programmed.

Modifying the programs of the device

Program inspection

Temporary manual mode until the next program switching

The temporary manual mode can only be used in programmed mode until the next program switching. For activation, with buttonsCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (15) andCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (16) , modify the temperature/humidity set according to programming. After setting, the program number disappears and iconCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (22) appears on the display, indicating that the thermostat will be operated by temporary manual control until the next program switching. Following this, the thermostat will maintain the modified temperature/humidity until the time of the next switching, and during this time
the temperature and humidity can be freely modified with buttons and .
During the temporary manual mode the segments indicating the time on the display alternately show the exact time (TIME), and the time remaining in manual control (TIME LEFT) (e.g.4:o2, that is 4 hours and 2 minutes). After this time, the icon disappears and the device returns to the set program. If you wish to return to the set program before the switching time, touch the button.

Temporary manual mode for 1 to 99 hours (party program)

Temporary manual mode for 1 to 99 days (holiday program)

OPERATION OF BACKLIGHT

By factory default the backlight of the thermostat automatically switches on for 15 seconds after touching any button. Regardless of the automatic backlight, touching the button you can switch on/off the backlight. If you touch any button while the backlight is active, the backlight will go out only 10 seconds after the last button has been touched.
You can modify the automatic backlight of the thermostat, the backlight of the keys and the backlight brightness as described in Chapter 7.

LOCKING THE CONTROL BUTTONS

You can switch off the control buttons of the thermostat to prevent the settings from accidental or unauthorized modifications. Touching the button for 2 seconds you can lock and unlock the control buttons. The icon appearing/ disappearing in the right bottom corner of the display indicates the locked/ unlocked state of the control buttons
By default setting the thermostat automatically locks the control buttons 30 seconds after the last button has been touched. This setting can be switched off as described in Chapter 7.

BATTERY REPLACEMENT

The average life span of the batteries is 1 year, but frequent use of backlight can shorten this period considerably. When the iconCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (7) indicating low voltage supply flashes on the display, the batteries should be replaced (see Chapter 5.2.).
The exact time should be set again after the batteries have been replaced, but the device saves the program that has been loaded as well as the settings even without batteries therefore there is no need to reprogram or reset them.
Attention! Only high-quality alkaline batteries may be used in the device. So-called durable or long-life zinc-carbon batteries are unsuitable for the operation of the devices. The low battery iconCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (7) appearing on the display warns the necessity of battery replacement reliably only when high-quality alkaline batteries are being used.

FREQUENTLY ASKED QUESTIONS

When you think that your appliance is operating incorrectly or encounter any problem while the appliance is being used then we recommend that you read Frequently Asked Questions (FAQ) available on our website, where we collected the problems and questions that most frequently occur while our appliances are being used, along with the solutions thereto:
https://www.computherm.info/en/faqCOMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (27)
The vast majority of the problems encountered can be solved easily by using the hints available on our website, without seeking professional help. If you have not found a solution to you problem, please pay a visit to our qualified service.

PRODUCT INFORMATION DATASHEET

Remark:
In addition to using modern temperature regulators, the following up-to-date regulation methods also contribute significantly to the improvement of the comfort provided by the heating network, the energy efficiency of the heating network and the coefficient of performance:

TECHNICAL DATA

The COMPUTHERM Q20RF type thermostat complies with the requirements of directives RED 2014/53/EU and RoHS 2011/65/EU.COMPUTHERM-Q20-Programmable-Digital-Room-Thermostat-FIG- (27)
Manufacturer: QUANTRAX Ltd. Fülemüle u. 34., Szeged, H-6726, Hungary
Phone: +36 62 424 133
Fax: +36 62 424 672
E-mail: [email protected]
Web: www.quantrax.hu
www.computherm.info
Origin: designed in the EU, manufactured in China Copyright © 2022 Quantrax Ltd. All rights reserved.

REFERENCE:

DOWNLOAD MANUALS:

COMPUTHERM Q20 Programmable Digital Room Thermostat Operating Instructions

COMPUTHERM-logo

COMPUTHERM Q20 Programmable Digital Room Thermostat Operating Instructions

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)