SIEMENS-LOGO

SIEMENS RDU340 Flush-mount Room Thermostat

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-prodct

Flush-mounted room thermostat

SPECIFICATION

Use

Control of the room temperature in individual rooms of ventilation or air conditioning plants that are:

The RDU340 is suitable for use with VAV systems in connection with the VAV compact controller types G…B181.1E/3.
The RDU340 can also be used as an AHU temperature controller in connection with valve actuators, as well as for universal heating and cooling applications with DC 0…10 V actuators.

The RDU340 controls

Use in systems with:

Functions

Applications

Prior to snapping the front panel to the base, use the DIP switches on the inner side of the front panel to commission the thermostat’s applications and the behavior of the output signal.

Application and output signal, DIP switches, diagram

V1 Heating or heating/cooling valve actuator
B1 Return air temperature sensor or external room temperature sensor (optional)
E1 Electric heater
B2 Changeover sensor (optional)

Note

During startup, the thermostat reloads the control parameter factory settings after each DIP switch settings change

Type summary

 

 

Product no.

 

 

Operating voltage

Control output Backlit LCD Infrared receiver Housing color
 

3-pos

 

on/off

 

DC 0…10 V

RDU340 AC 24 V white

Equipment combinations

DC 0…10 V actuator

Designation Product no. Data Sheet*)
Cable temperature sensor or changeover sensor, cable length 2.5 m

NTC (3 kn at 25 °C)

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (6)  

QAH11.1

 

1840

Room temperature sensor NTC (3 kn at 25 °C) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (7) QAA32 1747
Electrical actuator, DC 0…10 V (for radiator valve) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (8)  

SSA61…

 

4893

Electrical actuator, DC 0…10 V (for 2- and 3-port valves / V…P45) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (9) SSC61… 4895
Electrical actuator, DC 0…10 V (for small valve 2.5 mm) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (10) SSP61… 4864
Electrical actuator, DC 0…10 V (for small valves 5.5 mm) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (11) SSB61… 4891
Electrical actuator, DC 0…10 V (for CombiValves VPI45) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (12) SSD61… 4861
 

Electromotoric actuator, DC 0…10 V (for valves 5.5 mm)

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (13)  

SQS65…

 

4573

Electrothermal actuator,

AC 24 V, NC, DC 0…10 V, 2 m

(for radiator valves and small valve 2.5 mm)

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (14)  

STA63

 

4884

Electrothermal actuator,

AC 24 V, NO, DC 0…10 V, 2 m

(for radiator valves and small valve 2.5 mm)

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (15)  

STP63

 

4884

 

 

 

 

 

 

 

 

DC 0…10 V damper / valve actuator

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (16) GQD161… 4605
SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (17) GDB161…  

4634

GLB161…
SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (18) GMA161… 4614
 

GEB161…

 

4621

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (19) GCA161… 4613
GBB161…  

 

4626

GIB161…
 

VAV compact controller

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (20)  

GDB181.1E/3

 

3544

The documents can be downloaded from http://siemens.com/bt/download

Accessories

Designation Product no. Data Sheet*)
Changeover mounting kit (50 pcs/package) ARG86.3 N3009
Plastic mounting spacer for flush mounted thermostats for increasing the headroom in the

conduit box by 10 mm

 

ARG70.3

 

N3009

Conduit box for flush mounted thermostat ARG71 / S55770-T137 N3009

The documents can be downloaded from http://siemens.com/bt/download.

Ordering

When ordering, indicate both product number and designation: E.g. RDU340 room thermostat
Order valve actuators separately

Mechanical design

The thermostat consists of 2 parts:

The rear of the mounting base contains the screw terminals. The base fits on a square conduit box with 60.3 mm fixing centers. Slide the front panel in the mounting base and snap on.

Operation and settingsSIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (21)

  1. Operating mode selector / Protection
  2. Adjust setpoint and control parameters

DisplaySIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (22)

Mounting and installation

Mount the room thermostat on a recessed square conduit box with 60.3mm fixing centers. Do not mount on a wall in niches or bookshelves, behind curtains, above or near heat sources, or exposed to direct solar radiation. Mount about 1.5 m above the floor.SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (30)

Mounting

Wiring

See the mounting instructions M3078 enclosed with the thermostat.

Warning!

No internal line protection for supply lines to external consumers (Y10, Y21)
Risk of fire and injury due to short-circuits!

Commissioning

Note

After powerfail the thermostat restarts in the same mode as before.

Control sequence

The control sequence may need to be set via parameter P01 depending on the application. The factory setting for the single duct application is “Cooling only”.

Calibrate sensor

Recalibrate the temperature sensor if the room temperature displayed on the thermostat does not match the room temperature measured (after min. 1 hour of operation). To do this, change parameter P05.

Setpoint and range limitation

We recommend to review the setpoints and setpoint ranges (parameters P08…P12) and change them as needed to achieve maximum comfort and save energy

Disposal
The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage.

Technical data

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (31) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (32) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (33)

Connection terminals

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (34)

Connection diagrams

Application:
Single duct in VAV/CAV Heating or cooling for universal or AHUSIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (34)

Application:
Single duct with electric heater in VAV/CAV Heating and cooling with electric heater for universal or AHU

Warning

Dimensions

SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (37) SIEMENS-RDU340-Flush-mount-room-thermostat-Product-Specifications-fig- (38)

Dimensions in mm

© Siemens Switzerland Ltd, 2008 – 2019
Technical specifications and availability are subject to change without notice.
Issued by
Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH-6300 Zug
Tel. +41 58 724 2424
www.siemens.com/buildingtechnologies
Siemens Smart Infrastructure

REFERENCE:

DOWNLOAD MANUALS:

SIEMENS RDU340 Flush-mount room thermostat Product Specifications Guide

SIEMENS-LOGO

SIEMENS RDU340 Flush-mount Room Thermostat Product Specifications Guide

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)