MCC2/MCD2 Operations Manual – Hydronic

A Comfort Heat floor heating system has been installed on your floor. Underfloor heating will warm you from the floor up giving you an unparalleled feeling of comfort. This heating system is controlled by an electronic thermostat that has a floor sensor for optimum temperature
control.

PRIOR TO TURNING ON
The sub-floor and screed have to be fully cured before turning the heating on. For sand & cement screeds you must wait at least 3 weeks before turning them on. When turning on the floor for the first time, increase the floor temperature gradually over 2-3 days.

WARRANTY
THERMOSTAT & SENSOR – 2 years

RECOMMENDED TEMPERATURE SETTINGS

The MICROTEMP RANGE of electronic thermostats is specifically designed for underfloor heating systems. The thermostats are vertically flush mounted and have a 2-pole isolator with a 16A output relay.

MCC2/MCD2 – The MCC2/MCD2
the thermostat has a built-in programmable time clock to automatically turn the floor heating system ON and OFF at selected times. During the OFF periods, the floor does not turn OFF but programs the floor temperature to your selected ‘set back temperature’.When the appears on your screen, the floor is heating.  If you see ‘E1’ or‘E2’ there is an error.

TECHNICAL DATA

Comfort Heat Australia Pty Ltd
www.comfortheat.com.au
[email protected]
p: 02 9979 8600 f: 02 9979 7706

BASIC SET UP

Set the date and time when the thermostat is turned on for the first time or reset.

Press the tick button once you have the correct day displaying The thermostat is now set to ‘factory default’ settings and is fully operational.

The default setting for MCC2 – floor sensing
The default setting for MCD2 – air sensing
If your thermostat has already been set up but you are not sure if the settings are correct, you can reset your thermostat by pressing a pin into the reset hole for 3 seconds. You will need to then set the time and day as listed above.

Default settings: weekdays

Note: thermostat does not “turn off” but changes to a “set back” temperature. This setback temperature can be changed.

MANUAL MODE SETUP

PROGRAMMABLE MODE SETUP
Please refer to our full thermostat manual to program customized settings.

MCD2 ONLY – AIR WITH FLOOR LIMIT / FLOOR ONLY / AIR ONLY MODE SETUP
Select between sensing modes

CONNECTING MCC2/MCD2 TO SMART POWER METER
The Smart Power Meter varies the power tariff rate at different times of the day. Overnight the rate is at the ‘Off Peak’ rate and during the afternoon and evenings there is the ‘Peak’ rate. At the times between these, there are ‘Shoulder’ rates. The exact times of these rates should be confirmed by your power provider. As the cost of electricity during ‘Peak’ times is more expensive than during the ‘Off Peak’ or ‘Shoulder’ times the MCC2 thermostat should be programmed to ‘TURN OFF’ when it is ‘Peak’ periods. Following is an outline of how to achieve this arrangement:- Set the Adaptive Function to ‘Off’ – The adaptive function is a program within the thermostat that tries to predict when the floor heating should be turned on to achieve the selected temperature at the ‘Time On’ setting. As this may allow the floor heat to operate during the ‘Peak’ period. Check this function is ‘Off’ in the thermostat program as follows:-

Type MCC2/MCD2 is electronic on/off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat. Type MCC2/MCD2 is for flush mounting in a wall socket.

Product program

Type MCC2-1991-UA
Mounting of floor sensor (fig. 3) The floor sensor is used for temperature regulation in floor surfaces. For easy replacement, the sensor can be mounted in a tube that is placed between 2 heating cables. The tube is ended towards the floor surface and is sealed. If required, the sensor cable can be extended up to about 100 m with a standard installation cable. 2 leads in a multi-lead cable, which is used as a supply cable for the heating cable, must not be used. Voltage signals may occur which may disturb the thermostat function. If a screened cable is used, the screen must not be earthed but must be connected to the terminal

Type MCC2-1999-UA and MCD2-1999-UA
Mounting of thermostat with built-in sensor (fig. 4) The room sensor is used for comfort temperature regulation in rooms. The thermostat is mounted on the wall with free air circulation about 1.6 m above the floor. Draught, direct sunlight, or any other direct heating outlet must be avoided.

Type MCD2-1999-UA
Mounting of limitation sensor: Max. temperature limitation is used for protection of installation or construction against excessive temperature. The sensor is mounted at a place where excessive temperature may arise. Min. temperature is used for better heating comfort. The sensor is mounted as a floor sensor.

Mounting of thermostat

  1. Release the front cover ONLY by inserting a small screwdriver into the air grills on both sides of the thermostat (see Fig. 1). DO NOT open the thermostat by releasing the four fixing clips on the back.
  2. Connect cables according to the diagram (fig. 2)Comfortheat-MCC2-Hydronic-Programmable-Thermostat-FIG-2
  3. The thermostat is mounted in the wall socket. The cover and the frame are remounted.

Operation

The first time the thermostat is connected, the time and day must be set:

Comfortheat-MCC2-Electric-Programmable-Thermostat-FIG-1

Programming
See the user’s manual.

Fault location
If the sensor is disconnected or short-circuited, the heating system is cut out. The sensor can be checked according to the resistance table Fig. 5.

Error codes

CE marking

Classification

OJ ELECTRONICS A/S
Stenager 13B · DK – 6400 Sønderborg
Tel: +45 73 12 13 14 · Fax: +45 73 12 13 13 www.oj.dk

REFERENCE:

DOWNLOAD MANUALS:

Comfortheat MCC2 Hydronic Programmable Thermostat Operating Manual

OTHER MANUALS:

Comfortheat MCC2 Electric Programmable Thermostat Setup Manual

Comfortheat MCC2 Programmable Thermostat User Manual

Comfortheat MCC2 THERMOSTAT Wiring Diagram

Comfortheat

Comfortheat MCC2 Hydronic Programmable Thermostat Operating Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)