Thermostat Application Guide

Description
Gas or Oil Heat Yes
Electric Furnace Yes
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (With Aux. or Emergency Heat) Yes
Multi-Stage Systems Yes
Heat Only Systems Yes
Heat Only Systems – Floor or Wall Furnace Yes
Cool Only Systems Yes
Millivolt Conventional Systems Yes
Two Transformer Systems No

Power Type
Hardwire (24V Common Wire)

Installation Tips

Wall Locations

The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation.

 Pro1 -Technologies- T855iSH- Non-Programmable- Thermostat- 1

Removing The Private Label Badge

Gently slide a screwdriver into the bottom edge of the badge. Gently turn the screwdriver counterclockwise. The badge is held on by a magnet in the well of the battery door. The badge should pry off easily. DO NOT USE FORCE. All of our thermostats use the same universal magnetic badge. Visit the company website to learn more about our free private label program.

 Pro1 -Technologies- T855iSH- Non-Programmable- Thermostat- 8

Subbase Installation

 Pro1 -Technologies- T855iSH- Non-Programmable- Thermostat- 2

  1. Horizontal Mount
  2. Vertical Mount

Mount Thermostat
Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.

 Pro1 -Technologies- T855iSH- Non-Programmable- Thermostat- 3

Getting to know your thermostatPro1 -Technologies- T855iSH- Non-Programmable- Thermostat- 1

  1. LCD
  2. Glow in the dark light button
  3. Fan button
  4. System button
  5. Easy change battery door
  6. Temperature setpoint buttons

Wiring

  • Power Supply
  • Factory-installed jumper, remove only when installing on a 2-installer system.
  • Use either O or B terminals for changeover value.
  • Use a small piece of wire (not included) to connect W and Y terminals.
  • Set fan operation to electric
  • A 24 VAC 500mA common connection is required with this thermostat.

Replacement Thermostat Wiring

  • If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced. In some cases, the wiring connections will not be color coded. For example, the green wire may not be connected to the G terminal.
  • Loosen the terminal block screws. Insert wires then retighten terminal block screws.
  • Place non-flammable insulation into the wall opening to prevent drafts.
  • This thermostat requires a 24V common wire to the C terminal.

Wiring Chart

For all systems, the following terminals are wired according to whether you have a single or dual transformer system as shown:

Technician Setup

To enter tech setup:

  •  Press and hold the + and – buttons for 3 seconds.
  •  Press the TECH button at the lower left.
  •  Configure the installer options as desired using the table below. Use the + or – buttons to change settings and the PREV and NEXT buttons to move from one step to another.
  •  To exit tech setup: press and hold the + and – buttons for 3 seconds, or wait 20 seconds.

Tech Setup continued

WIFI Setup

  • Press and hold the + and – buttons for 3 seconds.
  • Press the WIFI button at the lower right.
  • The top of the display will show:
  • “WIFI NOTOK” is NOT connected to WIFI. “WIFI OK” if connected to WIFI.
  • IF the NEXT button is pressed, the top of the display will show:
  • The firmware and software versions that are installed on the thermostat. You can scroll through them with the + and – buttons.
  • IF the NEXT button is pressed again, the top of the display will show:
  • The SSID # of the thermostat. if NEXT is pressed again, you will return to step 4.
  • Go through steps 1 and 2 from the WIFI menu at left.
  • Press and hold the TECH button at the lower left for 3 seconds.
  • The top of the display will show:
  • “RESET WIFI”
  • Press the YES button at the lower left. After a 5-second countdown, the thermostat will reset.
  • Or press NO to exit

REFERENCE

DOWNLOAD MANUAL

Pro1 Technologies T701 Programable Thermostats Installational Manual

OTHER MANUALS:

Pro1 Technologies T701 Programable Thermostats Operation Manual

Pro1-Technologie-logo

Pro1 Technologies T701 Programable Thermostats Installational Manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)