VIVE Comfort TP-N-501M Thermostat INSTALLATION MANUAL

Vive-LOGO

VIVE Comfort TP-N-501M Thermostat

VIVE- Comfort -TP-N-501M- Thermostat-pro

Wall Locations

The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulationVIVE- Comfort -TP-N-501M- Thermostat-1

Do not install thermostat in locations:

  • Close to hot or cold air ducts
  • That are in direct sunlight
  • With an outside wall behind the thermostat
  •  In areas that do not require conditioning
  •  Where there are dead spots or drafts (in corners or behind doors)
  •  Where there might be concealed chimneys or pipes

Thermostat Application Guide

  • For Use On
    • Most 24V Heating and A/C Systems Gas or Oil Heat
    • Electric Furnace
    • Heat Pump With NO Auxiliary Heat Heat Only Systems
    • Cool Only Systems
    • Millivolt Systems
  • NOT For Use On
    • Multi Stage Systems
    • Line Voltage Systems Compressors With No Built In Delay 3 Wire Hydronic Systems

Power Type

  • Battery Power
  • Hardwire (Common Wire)
  • Hardwire (Common Wire) with
  • Battery Backup

Private Label Badge

Subbase Installation

  • Horizontal Mount
  • Vertical MountVIVE- Comfort -TP-N-501M- Thermostat-2

Removing The Private Label Badge

Gently slide a screwdriver into the bottom edge of the badge. Gently turn the screwdriver counter clockwise. The badge is held on by a magnet in the front plastic. The badge should pry off easily. DO NOT USE FORCEVIVE Comfort TP-N-501M Thermostat 3

About The Badge

All of our thermostats use the same universal magnetic badge. Visit the company website to learn more about our free private label program.

Wiring

  • If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced.
  • In some cases the wiring connections will not be color coded. For example, the green wire may not be connected to the G terminal.
  • Loosen the terminal block screws.
  • Insert wires then retighten the terminal block screws.
  • Place nonflammable insulation into the wall opening to prevent drafts.

Terminal Designations

  • O Heat pump changeover valve energized in cooling
  • B Heat pump changeover valve energized in heating
  • W Heat relay
  • RH Transformer power for heating
  • RC Transformer power for cooling
  • G Fan relay
  • Y Compressor relay

Wiring Tips

  • RH & RC Terminals
    • For single transformer systems, leave the jumper wire in place between the RH and RC. Remove jumper wire for two transformer systems.
  • Wire Specifications
    • Use 18-22 gauge thermostat wire.
  • Heat Pump Systems
    • If wiring to a heat pump, use a small piece of wire (not supplied) to connect terminals W and Y.

Wiring DiagramsVIVE Comfort TP-N-501M Thermostat 4

Removing & Replacing The Front Cover

Remove Front CoverVIVE Comfort TP-N-501M Thermostat 5 Faceplate Application Options

VIVE Comfort TP-N-501M Thermostat 6

For HEAT ONLY without FAN:

    • Put the GAS/ELEC switch in the GAS position (Left).
    • Put the FAN in the AUTO (down) posi-tion. Then pull the FAN button off the switch. The faceplate will then cover and hide the FAN switch.VIVE Comfort TP-N-501M Thermostat 7

 

Anticipator Setting

Heating Anticipator Setting

Set the adjustable heat anticipator to match the current draw of the system in heat mode. With the thermostat wired to the HVAC system and mounted on the wall, remove the thermostat from the subbase. Place ammeter probes on the RH and W terminals. After one minute of heating runtime, the ammeter will show a steady current draw value. This current draw value in milliamps on the ammeter is the same value that the anticipator needs to be set to for best results. Set anticipator dial to match the steady ammeter reading in milliamps.

VIVE Comfort TP-N-501M Thermostat 5

 

Anticipator Settings

  • Higher anticipator values will allow longer running heat cycles.
  • Lower anticipator values will allow shorter running heat cycles.
  • Note: For millivolt systems, set anticipator to its lowest setting.VIVE Comfort TP-N-501M Thermostat 10

Replacing Application Faceplates

To remove faceplate from the front cover, press the back of the faceplate near the edge of the front cover until the faceplate snaps out of its place. Replace different faceplate by placing the new faceplate in open space on the front of the front cover. Press the edge of the faceplate into the front of the front cover until it snaps into place.VIVE Comfort TP-N-501M Thermostat 9

REFERENCE

DOWNLOAD MANUAL

VIVE Comfort TP-N-501M Thermostat INSTALLATION MANUAL

Vive-LOGO

VIVE Comfort TP-N-501M Thermostat INSTALLATION MANUAL


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)