Drayton Digistat +1 & Digistat +1RF RF710 Room Thermostat
BUILT FOR EASE
Drayton’s Digistat+1 features large buttons and an easy-to-read digital display, making it clear to see that the temperature has been set accurately.
It can be configured with a minimum temperature setting to protect the vulnerable.
- Simple on & off feature
- User adjustable min/max temperature setting
- User adjustable set-back feature
- User adjustable comfort feature
BUILT TO BE SIMPLE
The simplicity of the four buttons, teamed with the large and clear digital screen help the Digistat+1 to make your and your customer’s life less complicated.
HOW DO WE MEASURE UP?
PART NUMBERS
Product | Part No. |
Digistat+1 | 22192 |
TECHNICAL DATA
Model | +
Digistat 1 |
Power supply: | 2 X 1.5V IEC LR6(AA) alkaline batteries |
Switch type & rating: | SPDT 16(2)A 230V a.c. Volt free |
Min. recommended current: | 10mA@24V a.c. (inductive) |
Wiring: | Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671). |
Mounting: | Suitable for surface or conduit box mounting |
Battery life: | 2 years typical |
Ambient temperature: | Operating 0ºC to 40ºC
/Storage –20ºC to 55ºC |
Ambient humidity(non condensing): | Operating 25% to 90%
/ Storage 15% to 95% |
Temperature range: | 5 to 30ºC |
Temperature resolution: | 0.5°C |
Control accuracy: | + 0.5K @ 20ºC |
Ball pressure test: | 75ºC |
Pollution degree: | 2 |
Energy class: | IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013) |
Relevant EC directives: |
2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive 2006/66/EC Batteries Directive 2011/65/EU RoHS Directive |
Applied standards: | EN60730-1; EN60730-2-9 |
9° NETWORK
Join our professional installer club today and benefit from extended guarantees, priority support, and much more.
www.draytoncontrols.co.uk/9degrees
HEAR ALL THE NEWS
@draytonheating
WATCH OUR VIDEOS /Drayton controls
Technical Support: 0333 7000 622
Customer Services: 0333 6000 622
www.draytoncontrols.co.uk
[email protected]
*Calls cost 7p per minute plus your telephone provider’s connection charge
D104-2
In accordance with our continuous improvement procedures, we reserve the right to change design features and specifications without prior notification. The Data contained in this document is for guidance only. Drayton accepts no liability for any consequential losses, injury, or damage resulting from the use of this document or the information contained within.
REFERENCE
Download Manual
Drayton Digistat +1 & Digistat +1RF RF710 Room Thermostat Product Specifications Guide
OTHER MANUALS:
Drayton Digistat +1 & Digistat +1RF RF710 Room Thermostat Installation Guide
Drayton Digistat +1 & Digistat +1RF RF710 Room Thermostat Product Specifications Guide
Leave a Reply