Venstar T2800 Programmable Thermostat 

Venstar-T1700-Programmable-Thermostat-Thermostat

Features

Meets Commercial California Title 24
Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & 3 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat.

Installation Instructions

CAUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to “OFF” prior to changing settings in setup or restoring Factory Defaults.
NEVER PUT MORE THAN ONE JUMPER ON THE SAME MISC JUMPER BLOCK! THIS MAY DAMAGE YOUR THERMOSTAT AND VOID YOUR WARRANTY.

Venstar-T2800-Programmable-Thermostat-1

NOTE: Due to variations in environmental conditions, it is not always possible to achieve the desired humidification or dehumidification setpoint. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Venstar-T2800-Programmable-Thermostat-2

SECTION 1

Preparation 
Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.

Assemble tools Venstar-T1700-Programmable-Thermostat-Thermostat-1

SECTION 2

Remove & Replace the Old Thermostat

SECTION 3

Configuring the MISC Outputs

Configuring the Jumpers
For additional flexibility, your thermostat has three configurable outputs. These outputs are designed to have different functions depending on how the jumpers are set (below).
Each output, labeled MISC1, MISC2, and MISC3 may be set for one of the four choices available.
In the diagram below, the MISC3 jumper has been set for HUM*
(humidification) operation, the MISC2 jumper has been set for DEHUM* (dehumidification) operation, and the MISC1 jumper has been set for Y2 (second stage cooling) operation.Venstar-T2800-Programmable-Thermostat-3

CAUTION NEVER PUT MORE THAN ONE JUMPER ON THE SAME MISC JUMPER BLOCK!
DOING SO MAY DAMAGE YOUR THERMOSTAT AND VOID THE WARRANTY.

Venstar-T2800-Programmable-Thermostat-1

Explanation of Jumper Settings

W3 JUMPER SETTING 

If the jumper for MISC1, MISC2, or MISC3 is set to W3, the corresponding MISC screw terminal on the backplate will control a third stage of heat.
W3 MULTI-STAGE OPERATION EXPLAINED – SECTION 13 of the Owner’s The 3rd Stage of Heat is turned on when:

HUM JUMPER SETTING
If the jumper for MISC1, MISC2, or MISC3 is set to HUM, the corresponding MISC screw terminal on the backplate will control a humidification system.
HUMIDIFICATION OPERATION – SECTION 9 of the Owner’s Manual
If your HVAC unit is equipped with a humidification system and the Humidity Module (sold separately) has been installed, the thermostat will provide power to the MISC1, MISC2, or MISC3 terminal of the thermostat when the humidity in the home falls below the humidity setpoint you have chosen.
The value for this setpoint ranges from 0% to 60%. If no humidity is desired or if a humidification system has not been installed, set the value to OFF.

DEHUM JUMPER SETTING If the jumper for MISC1, MISC2, or MISC3 is set to DEHUM, the corresponding MISC screw terminal on the backplate will be connected to the dehumidification terminal of a furnace board.
NOTE: Not all furnaces have a dehumidification terminal.
DEHUMIDIFICATION OPERATION – SECTION 10 of the Owner’s Manual
If your HVAC unit is equipped with a dehumidification system the thermostat will operate in one of two ways.

  1. Normally Closed (NC): The thermostat will de-energize the MISC1, MISC2, or MISC3 terminal of the thermostat (this MISC terminal is connected to the DEHUM terminal on your furnace) to allow the fan to run in low speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling.
  2. Normally Open (NO): The thermostat will energize the MISC1, MISC2, or MISC3 terminal of the thermostat (this MISC terminal is connected to the DEHUM terminal on your furnace) to allow the fan to run in low speed when the humidity in the home is above the dehumidify setpoint you have chosen and there is a call for 1st stage cooling.

Y2 JUMPER SETTING

If the jumper for MISC1 is set to Y2 the MISC1 screw terminal on the backplate will control a second stage of cooling. Y2 OPERATION – SECTION 13 of the Owner’s Manual

Control up to two Cool stages.
The 2nd Stage of heat or cool is turned on when:

SECTION 4

Wire Connections
If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams 4 that follow.Venstar-T2800-Programmable-Thermostat-6

Note: O/B is used if your system is a Heat Pump.

SECTION 5

Sample Wiring Diagrams 
6 Wire, 1 Stage Cooling, 1 Stage Heat Residential & Commercial 1 Stage Cooling, with 1st Stage Gas Heat
OR
Commercial Heat Pump 1 Stage Cooling with 2 Stage HeatVenstar-T2800-Programmable-Thermostat-7

6 Wire, 1 Stage Cooling, 1 Stage Heat 
Residential & Commercial 1 Stage Cooling, with 1st Stage Electric Heat

Venstar-T2800-Programmable-Thermostat-8

6 Wire, 1 Stage Cooling, 2 Stage Heat 
Residential Heat Pump with O Reversing Valve 1 Stage Cooling, with 2 Stage Heat

 

6 Wire, 1 Stage Cooling, 2 Stage Heat
Residential Heat Pump with b Reversing Valve 1 Stage Cooling, with 2 Stage Heat

Venstar-T2800-Programmable-Thermostat-10

Adding a (MISC1) 2nd Stage of Cooling and a 3rd Stage of Heating (MISC3). Adding a Humidification System (MISC1) and Dehumidification System (MISC2)*.Venstar-T2800-Programmable-Thermostat-11

Adding a Humidification System (MISC1) and Dehumidification System (MISC2)*.

Venstar-T2800-Programmable-Thermostat-12

Requires Humidity Module.

Installing the Outdoor Sensor

The Outdoor Sensor measures outdoor air temperature and sends this information to the thermostat; it measures temperature with a range of -40 to 127 F.
The Outdoor Sensor should be connected to the thermostat using solid conductor CAT 5, CAT 5e, or CAT 6 type network commun-ication cable. This is an unshielded cable with four twisted pairs of
24 gauge solid wire; DO NOT use stranded cable. The cable length should not exceed 250 feet. If less than 75 feet of cable is required to connect the thermostat to the Remote Sensor, a three conductor thermostat cable (18-24 gauge) may be used; this cable is NOT suitable for any length greater than 75 feet.
IMPORTANT: Do no use shielded wire. Do not run sensor wiring in the same conduit as the 24VAC thermostat wiring. Electrical interference may cause the sensor to give incorrect temperature readings.
See the Outdoor Sensor accessory for further details.

SECTION 6

Test Operation

SECTION 7

Calibrating the Thermostat Sensors 
Under normal circumstances it will not be necessary to adjust the calibration of the temperature and humidity sensors. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure. Venstar-T2800-Programmable-Thermostat-13

After calibration is complete, press the MODE button to return to normal operation.

SECTION 8  TroubleShooting

References:

Download Manual

Venstar T2800 Programmable Thermostat Installation Instructuion

OTHER MANUAL

Venstar T2800 Programmable Thermostat Owner Manual

Venstar-logo

Venstar T2800 Programmable Thermostat Installation Instructuion

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)