Installation Instructions

CAUTION: Failure to read and follow all installation and operating instructions could lead to personal injury and/ or damage to property.
CAUTION: All electrical installations must comply with local building and safety codes and must be performed by qualified personnel only.

System Overview

Included in Kit

Additional Requirements
Depending on application and installation, the following additional items may be required:

Installation of the Appliance Control Box

Masterstat-110423-2-Wall-Control-Wired-Thermostat-fig.1
CAUTION: To prevent electrical shock and/or damage to the equipment, disconnect electrical power to the system at the main fuse or circuit breaker before starting the installation, and leave disconnected until the installation is complete.

  1. After determining a suitable place to install the Appliance Control Box, mark the location of the three mounting points (with the ‘TOP’ indication uppermost) and drill pilot holes for the mounting screws.
  2. Determine which knockout locations will be used for the system wiring.
  3. Using a suitable tool, cut out the required knockouts. Make sure you cut out the correct size hole for your fitting.
  4. Mount the box using suitable screws.
  5. Install conduit and connections, ensuring a watertight seal, especially around the locations where the knockouts were removed.
  6. Run wiring, in accordance with local and national electrical codes, to suit the installation.
  7. Connect the wires in accordance with the wiring diagram on next page (wiring diagram also located on the inside lid of Appliance Control box).
    WARNING: Use the jumper wire between Link and NLink only when fan and pump voltages are the same.

Wiring Connections in Appliance Control Box

Masterstat-110423-2-Wall-Control-Wired-Thermostat-fig.2

Installation of the Wall Control – cavity wall without outlet box

Masterstat-110423-2-Wall-Control-Wired-Thermostat-fig.3

  1. Determine a suitable place to install the Wall Control (away from sources of heat, sunlight, or ventilation, and between 4 and 6 feet from the floor). Do not install near cooler opening.
  2. Using the mounting plate as a guide, mark the location of the two mounting points and the terminal opening for the connection terminal.
  3. Make a hole in the wall just large enough to accommodate the connection terminal and associated wiring.
  4. Route an insulated three-conductor thermostat cable (or similar low voltage cable) from the Appliance Control Box through the hole, leaving about six inches protruding.
  5. Route the wiring through the opening in the wall control mounting plate. Using wall anchors, screw the mounting plate to the wall.
  6. Connect the wires to the terminals as per the wiring connection diagram below. These same wire colors match those indicated on the control box.
  7. Plug the connection terminal into the back of the wall control. Place the tabs on the mounting plate into the holes in the top of the thermostat and rotate the Wall Control until it snaps onto the mounting plate. You may use the provided screw to secure it in place.

Installation of the Wall Control – using an existing wall-mounted outlet box
CAUTION: Only use a single outlet box and do not share wiring with any other equipment.

Masterstat-110423-2-Wall-Control-Wired-Thermostat-fig.4

Masterstat-110423-2-Wall-Control-Wired-Thermostat-fig.5

  1. Route an insulated three-conductor thermostat cable (or similar low voltage cable) from the Appliance Control Box to the outlet box, leaving about six inches protruding.
  2. Route the wiring through the opening in the wall control mounting plate. Screw the mounting plate to the outlet box.
  3. Connect the wires to the terminals as per the wiring connection diagram below. These same wire colors match those indicated on the control box.
  4. Plug the connection terminal into the back of the wall control. Place the tabs on the mounting plate into the holes in the top of the thermostat and rotate the Wall Control until it snaps onto the mounting plate. You may use the provided screw to secure it in place.

Operating Instructions

Automatic Operation

Manual Operation

Time Delay Operation

Delayed start or stop in ‘Auto’ or ‘Manual’ mode

In the event of a power outage
When power is restored after a power failure, the thermostat will resume operation in the mode selected prior to the power outage.
Temperature adjustment
Press the up and down arrow buttons simultaneously for 3 seconds. Using the up or down arrow buttons you may adjust the room temperature plus or minus 3 degrees from the set point. This will allow for small adjustments in the temperature displayed on the LCD.

Trouble Shooting Guide

The guide below is intended to aid an Installer or Service Technician in resolving simple problems.
CAUTION: To prevent electrical shock and/or damage to the equipment, disconnect electrical power to the system at the main fuse or circuit breaker before opening the appliance control box, and leave disconnected until after the lid has been shut and secured.
CAUTION: Any testing performed on live conductors must be carried out by qualified personnel only.

REFERENCE

Download manual:

Master stat 110423-2 Wall Control Wired Thermostat Installation Instructions

Masterstat-logo

Master stat 110423-2 Wall Control Wired Thermostat Installation Instructions

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)