Honeywell logo

HONEYWELL HR20 Programmable Radiator Thermostat

HONEYWELL- HR20- Programmable -Radiator -Thermostat- pro

Checking after unpacking

The Rondostat packaging contains:

HONEYWELL- HR20- Programmable -Radiator -Thermostat- 1

Inserting/changing batteries

Setting date and time
After the batteries have been inserted or replaced, the Rondostat automatically requires the date and time to be entered.

Correcting the date and time

Rondostat changes over automatically from Summer to standard time. If however, you want to correct the date and time during operation:

Mounting

Rondostat can be mounted easily on all common radiator valves without causing any dirt or water staining. You no longer require the old thermostat head:

Selecting the adapter

Mounting the valve baseplate

HONEYWELL- HR20- Programmable -Radiator -Thermostat- 5

Attaching the operating unit

What is a thermostatic radiator valve (TRV)

TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler. They should be set at a level that gives you the room temperature you want. These settings may have to be different in each room, and you should set the TRVs to suit each room and then leave them to do their job. Turning a TRV to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the boiler size and setting, and the radiator size. Turning the TRV to a lower setting will result in the room being controlled at a lower temperature, and saves energy. TRVs need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. TRVs cannot turn off the boiler when the house is warm. To do that, you will need a room thermostat as well. The radiator in the room with the room thermostat should not normally have a TRV, but, if it does, keep the TRV on the maximum setting and adjust the room thermostat as explained with the instructionsHONEYWELL- HR20- Programmable -Radiator -Thermostat- 9

Adapter tableHONEYWELL- HR20- Programmable -Radiator -Thermostat- 10

Operating elements and display

How Rondostat works

Temperatures and control periods
Rondostat differentiates between two temperatures:

In automatic mode Rondostat changes between these two temperatures in accordance with an adjustable time program:

Time program
The heating and economy periods (the 2nd heating period is optional) are specified by freely programmable time programs. The factory default  setting for the time program is:

To set the Rondostat

Adjustment dial
Use the adjustment dial to change the current room temperature to the next switching point in automatic mode.

Setting the comfort and economy temperatures

Operating hints

Operating the Rondostat comfortably
In order to adjust the time program comfortably turn the retaining bracket upwards and remove the operating unit (display E2). Slide the operating unit back on afterward. Turn the retaining bracket to the rear (display E2 disappears).

Lost your way in the program?
Press the AUTO button. Rondostat reiects the last entry and returns to Auto or Manu mode.

Time program: Heating and economy periods
Rondostat disposes of 2 independent time programs Select the week or day programs.

Setting the week programs (all days identical):

Deleting switching points

Rondostat is always awake!

Window function
If you open a window so that the temperature drops quickly, the Rondostat closes the radiator valve in order to save energy. The message OPEn is displayed. When the temperature rises again – or 30 minutes have passed – Rondostat opens the valve again. You can also open the valve beforehand by pressing the PROG button or turning the adjustment dial.

Note: This functionality is only effective when the Rondostat is located directly within the flow of cool air from an open window.

Valve protection
If the valve has not been opened once completely within the period of a week, Rondostat automatically opens the valve briefly on Mondays in order to prevent seizing (display CYCL.).

Frost protection
If the temperature drops below 4°C, the Rondostat opens the radiator valve until the temperature rises above 6°C again. In this way Rondostat prevents the radiator from freezing.

Other setting options

Heating break

Child-proofing

Valve lift settings

Rondostat operates with a factory setting with the optimum valve lift (default lift) that is required for room temperature control.

Full-stroke mode
If the entire valve stroke is to be used or if the valve does not close completely, change to the full-stroke mode.

Default-stroke mode
Press and hold the Prog button and slide the operating unit onto the valve baseplate and lock it (display dEF).

Closing the radiator valve

Empty batteries
If bAtt is displayed permanently, the radiator valve is opened.

TroubleshootingHONEYWELL- HR20- Programmable -Radiator -Thermostat- 20

Emergency operation when batteries are flat

Restoring the factory settings

WEEE directive 2002/96/EC – Waste Electrical and Electronic Equipment directive
Dispose of the packaging and product in a corresponding recycling center. Do not dispose of the unit with domestic refuse. Do not burn the product.

REFERENCE

DOWNLOAD MANUALS:

HONEYWELL HR20 Programmable Radiator Thermostat Operating Manual

Honeywell logo

HONEYWELL HR20 Programmable Radiator Thermostat Operating Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)