TRANE XR302 Programmable Thermostats
Trane™ Thermostats Programmable and Non-programmable
Trane offers a line of programmable and non-programmable commercial thermostats for conventional (rooftop) air conditioners and heat pumps. Features and benefits include:
- Intuitive Liquid Crystal Display— are easy to use and read for all users and languages.
- Soft-touch Buttons or Touch Screen— both are easy and responsive for setup.
- Configurable— permits usage in conventional (RTU) systems or heat pumps with and without auxiliary heat.
- Dehumidification— only with touch screen model.
Part Numbers
Model |
X Code |
Clarksville |
Global Parts |
Thermostat, non-programmable, 1-heat/1-cool | X13511535010 | BAYSTAT151A | THT02772 |
Thermostat, non-programmable, 3-heat/2-cool | X13511536010 | BAYSTAT155A | THT02773 |
Thermostat, programmable, 3-heat/2-cool | X13511537010 | BAYSTAT150A | THT02774 |
Thermostat, programmable, touch screen, 3-heat/2-cool/dehumidification | X13511538010 | BAYSTAT152A | THT02775 |
Specifications
Category | Specification/Description |
Input power: | 24Vac, 50 Hz or 60 Hz (18 Vac to 32 Vac) |
Wire size: | 18 to 22 AWG |
Output terminal ratings: | 1A resistive load @ 30 Vac |
Temperature display
ranges: |
• Non-programmable: 32°F to 99°F (0°F to 37°C)
• Programmable Push Button: +15 to +122 ºF (-9.5 to +50 ºC) • Programmable Touch Screen -45°F to 199°F (-42.8°C to 92.8°C) |
Temperature setpoint
ranges: |
• Heat Setpoint: 40°F to 90°F (4.5°C to 32°C)
• Cool Setpoint: 50°F to 99°F (10°C to 37°C) |
Display type: | LCD |
System modes: |
• Heat
• Cool • Auto • Off • Emergency Heat (NO Emergency Heat on 1H/1C non-programmable model) |
Fan modes: | • On
• Auto |
Only Programmable: | |
Remote temperature
sensor: |
The thermostat includes terminals for a remote temperature sensor. They can be used for display, H/C control, or heat pump compressor lockout. The remote sensor must be 10K type 2. Recommended sensors include: Zone Temperature Sensor BAYSENS077A (X1351152801, SEN01488) or Duct Temperature Sensor BAYSTAT170A (41901133, SEN01287) |
Scheduling options: | 5/2 day; 5/1/1 day; 1 day; 7 day.
Two (Day/Night) or four (Morning/Day/Evening/Night) configurable periods per day. |
Temporary override: | Users can temporarily change the temperature setpoints, fan mode, and/or occupancy setting from the programmed schedule. |
Lockout: | System, fan, and/or schedule settings can be locked out individually on the programmable push button model. The touch screen locks out all functions at the same time except for Clean Screen and Filter Change functions. |
Only Touch Screen: | |
Remote humidity sensor: |
Touch screen thermostat has an internal humidity sensor and is capable of including a remote humidity sensor. The remote humidity sensor must be a 4–20 mA, 24 Vdc type. Recommended humidity sensors: Wall Mount BASYSENS036A (X1379044401, SEN01177) and Duct Mount 4190 7020 (X1379044501). |
Humidity display range: | 0% to 99% (1% steps) |
Humidity setpoint range: | 30% to 80% (1% steps) |
Dimensions
Dimension |
Programmable |
Non- Programmable | Programmable Touch-screen | DIAGRAM |
H | 4.7 in. (119 mm) | 4.7 in. (119 mm) | 3.3 in. (85 mm) | ![]() |
W | 3.3 in. (83 mm) | 3.1 in. (78 mm) | 5.9 in. (150 mm) | |
D | 1.1 in. (28 mm) | 1.1 in. (28 mm) | 1.3 in. (33 mm) | |
M | 3.3 in. (85 mm) | 3.3 in. (85 mm) | 3.3 in. (85 mm) | |
Wire Terminals
Label |
Description |
Non-Programmable | Programmable | ||
1Heat/ 1Cool | 3Heat/ 2Cool | 3Heat/ 2Cool | Touch Screen | ||
(O/B)W | (Changeover valve)(a) Heat relay | ![]() |
![]() |
![]() |
![]() |
(Aux/E)W2 | (Auxiliary or Emergency heat relay)(a) Second-stage heat | ![]() |
|||
(W1)W2 | (Emergency heat relay)(a) Second stage relay | ![]() |
![]() |
||
A | Economizer relay | ![]() |
![]() |
||
C | Common | ![]() |
![]() |
![]() |
![]() |
Dh | Dehumidify relay | ![]() |
|||
G | Fan relay | ![]() |
![]() |
![]() |
![]() |
Hp | External humidity sensor power | ![]() |
|||
Hs | External humidity sensor input | ![]() |
|||
(L) | (Emergency heat indicator relay)(a) | ![]() |
|||
R | 24 Vac heating | ![]() |
![]() |
![]() |
![]() |
Rc | 24 Vac cooling | ![]() |
![]() |
![]() |
![]() |
S1 | External temperature sensor | ![]() |
![]() |
||
S2 | External temperature sensor | ![]() |
![]() |
||
Y | Stage 1 compressor control relay | ![]() |
![]() |
![]() |
![]() |
Y2 | Stage 2 compressor control relay | ![]() |
![]() |
![]() |
(a) Text in parentheses applies to only heat pump systems.
Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable, and energy-efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com.
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
© 2011 Trane. All rights reserved.
BAS-PRC036-EN 28 July 2011
Supersedes BAS-PRC036-EN 01 Mar 2010
REFERENCE
DOWNLOAD MANUALS:
TRANE XR302 Programmable Thermostats Data Sheet
Leave a Reply