PERRY -1TP-TE028B -DIGITAL- THERMOSTAT- fea

PERRY 1TP-TE028B DIGITAL THERMOSTAT INSTRUCTION MANUALS

Perry-LOGO

PERRY 1TP-TE028B DIGITAL THERMOSTAT  

PERRY- 1TP-TE028B- DIGITAL- THERMOSTAT  - pro -

PRESENTATION

Dear Customer, thank you for choosing our product.
The thermostat, suitable for all heating and/or cooling system, is fitted with a large and clear backlit display to keep all its functions under control in real-time. The fundamental feature is its easy-to-use menu navigation, which makes it extremely user-friendly despite its comprehensive range of functions. The thermostat is factory-set to adjust temperature in a Differential ON/OFF manner and hysteresis can be set from 0.2°C to 1.2°C to adapt to the thermal inertia of your specific installation. Alternatively, modulating Proportional operation may be selected with settable duration cycles (from 7 to 20 minutes): this system ensures the desired temperature is maintained more stable, increasing user comfort and is particularly suitable for installations with high thermal inertia such as, for instance, for underfloor radiant panels. The set temperature scale is in degrees Centigrade (Celsius) with the option to calibrate room temperature measurement by setting a correction value (from -3 to +3 °C). The thermostat can be connected to a separate remote controllable temperature probe (optional) which may then be set according to one’s installation needs: remote, floor, external. Special attention was devoted to energy saving: pausing for household cleaning, optional Set temperature (MAX/MIN) lock, adjustable anti-freeze temperature value, and control through an external contact (e.g. optional telephone programmer), are conducive to avoiding wasting energy with consequent savings. See the following pages for a description of these as well as of other features

WARNINGS!

  • Read this manual carefully before using the product as it provides important guidelines regarding safety, installation, and use.
  • The manual must be preserved with care for future reference.
  • The installation and electrical connection of the thermostat must be implemented by qualified personnel and in conformity with current laws and regulations.
  • The thermostat is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or by those with a lack of experience and knowledge of the instructions, unless they are supervised or have received the necessary instructions concerning use of the device by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the device.
  • If -5 °C or+37.7 °C (+23°F or+99.9 °F) room temperature flashes on the display, the measured temperature is beyond the scale.
  • If “Err” flashes on the display, it indicates a faulty probe: any temperature control activity is suspended.
  • Use 2 stilo alkaline 1.5V batteries type AA (LR6). Batteries are not included.
  • N.B.: the product has been tested and its characteristics are guaranteed when alkaline DURACELL or ENERGIZER batteries are used.
  • If necessary, gently clean the thermostat and the display with a soft, dry cloth.
  • The manufacturer reserves the right to introduce any technical and/or constructive changes deemed necessary, with no prior notice

TECHNICAL DATAPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 1 

FACTORY SETTINGS
The data entered in the thermostat called «FACTORY SETTINGS» refer to the operation defined as «Standard». The following chapters describe all customizable functions, in order to satisfy any ambient comfort need

FACTORY SETTINGS TABLE (default)PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 2

RESTORE «Installer RESET»
Restore many factory settings (default) RESTORE brings the thermostat back to factory settings with the exception of some items as shown in the table; to perform the operation follow the instructions in paragraph 11.13.

RESTART
Should the thermostat feature malfunction, wrong displays or other incorrect conditions, perform a «User reset». Simultaneously press for 4 secs. the menu and keys. The thermostat resumes normal operation.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 3

KEY FUNCTIONS

Backlit display
Touching any key activates back-lighting, displaying the selection and navigation of the words , press the desired key within 6 sec. to vary the settings (touching any key reactivates a 6 secs. time-out).PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 4 PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 5

DISPLAY FEATURESPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 6 PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 7

INSTALLATION

DIMENSIONSPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 8

INSTALLATION EXAMPLE

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 9

FASTENING THE WALL BASE

Switch off mains power 230V~ to the device
Fasten the base of the thermostat with the screws supplied: to the wall, to the rounded or rectangular recessed box via the relatively paired holes A

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 10

  • A- base fastening holes: wall-mounted, round or rectangular recessed box
  • B – wire passage from corrugated tubes, round or rectangular recessed box
  • C – thermostat hooking teeth
  • D – thermostat fastening slot
  • E – screws to fasten the wall base to the rectangular or round recessed box.

ELECTRICAL CONNECTIONS

Important: the installation and electrical connection of the devices and appliances must be implemented by qualified personnel and in conformity with current laws and regulations. The manufacturer declines all liability in connection with the use of products subject to special environmental and/or installation standards.

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 11

Examples of electrical connectionsPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 12

After having made the electrical connections:

  • Apply the terminal cover to the base, securing it to hook E.
  • To remove the cover, use a small screwdriver on hook E for leveragePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 13
  • Hook the thermostat to the wall base in teeth C.
  • Then press the thermostat at the bottom to complete fastening in slot D.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 15
  • Unhook the thermostat from the wall base, using a screwdriver in the specific slot (D) in the lower part of the device for leverage, then turn to remove it. PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 16

Convenient programming

All setting operations may be performed before fastening the device to the wall base; this means setting may be carried out while comfortably seated. The flashing ON indication with fixed winter or summer symbol and the item NO RELAY indicates that the thermostat is detached from the wall base. Should the thermostat setting take place before fastening to the wall base, upon completing installation the ON indication (off or flashing) on the display might not correspond to the actual relay status. Within 1 minute at the most after fastening the thermostat to the wall base, the relay activates with the indication ON (off or flashing) displayedPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 14

SIGNALLING BATTERIES LOW OR DOWN
When the symbol blinks, this indicates that the batteries are running out and as from this moment, there are 15 days to replace them. Note: the backlight of the display is automatically deactivated. If the discharged batteries are not replaced within this time the display will completely turn off. All thermoregulation is suspended and all settings are saved to be restored when the new batteries are inserted.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 17

INSERTING OR REPLACING BATTERIES
Unhook the thermostat from the wall base (see previous paragraph) Insert the batteries, respecting the polarity. Hook and fix the thermostat to the wall base (see previous paragraph)PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 19

START THE THERMOSTAT

Upon the first insertion of the batteries, the thermostat performs a lamp test by switching on all display segments, displaying the installed software version for a few seconds. When this phase is over, the thermostat asks to select the language of use PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 20Select the desired language by scrolling through the available languages using the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21keys. Confirmpressing the key. The selectable languages are: ITALIAN = It (default), ENGLISH = En, FRENCH = Fr, GERMAN=dE, SPANISH=ES. Press 2 time the back key.

The thermostat is operative, displaying: Winter «heating» mode, the temperature Set at 20°C COMFORT, and room temperature detected. From normal thermostat operation in standby, pressing a key lights up the display (unless back-lighting has been disabled) and the selection and navigation of the words appear. Within 6 secs., a variation is made the second time the desired key is pressed.

USE OF THE THERMOSTAT

Press the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21MENU key brieflyPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 22

MODIFICATION OF T Set TEMPERATURE SET
Directly press the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21keys.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 23

In the presence of max and min. temperature locks (see paragraph 11.6) it is not possible to set a Set t higher or lower than the entered locks. The display will signal the impossibility to perform the operation by displaying

TEMPERATURE CONTROL PAUSE (example for household cleaning)

Pressing the key connected user will switch off for a max 3- hour period during which the thermostat will enter antifreeze mode ( t ). After 3 hours the thermostat temperature control will resume. It is possible to restart temperature control before the 3 hours have elapsed, press «back»: theword «CLEANING» disappears.

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 24

Note: in the event antifreeze temperature has been permanently disabled or in “Summer” operation, the connected user (e.g. boiler or air conditioner) will remain disabled for 3 hours maximum

OFF (disabling the thermostat)

  • This setting has the purpose of locking thermostat functions when heating or cooling must remain off.
  • In «CLEANING» mode (par. 7.3), press the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 26button briefly to set the thermostat to OFF and consequently «Switch off the system».PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 25
  • The display shows OFF, to indicate that the thermostat is disabled and all functions are inactive; the display only shows room temperature reading, the descaling function, if enabled and (in WINTER mode) the temperature Set plus the antifreeze protection symbol
  • Press key to reactivate the thermostat

STRUCTURE OF THE MAIN MENUS (use and configuration)

  • UNIT (selection of temperature unit of measure °C/°F)
  • OFFSET (correction of detected room temperature)
  • BLOCKS (it lets you limit the value of set temperature points)
  • PROBE (setting a remote temperature probe)
  • INPUT (setting an external contact for remotely enabling / disabling the programmable thermostat)
  • PUMP ON (disabling / enabling the descaling function)
  • CONTRAST (to change display contrast)
  • BACKLIGHT (to enable/disable display backlighting)
  • PASSWORD (to restrict the use of user and/or installer functions of the thermostat)
  • RESTORE (RESET operation)

ACCESS TO MENUS

From normal thermostat operation, press the Menu key for 3 secs. to access the first available menu.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 28

SET WINTER OR SUMMER MODE

  • From normal thermostat operation, access the menus by pressing and holding the «Menu» key.
  • Under itemSEASONSEt confirmwith OK.
  • Select with the keysPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 the WINTER (heating) or SUMMER(cooling) mode and confirmwith OK.
  • Press the «back» key to exit.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 29

MODIFICATION OR DISABLING OF SET ANTIFREEZE TEMPERATURE

  • From normal thermostat operation, access the menus by
  • pressing and holding the «Menu» key.
  • Use the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21keys to select the item SET TEMP Set.
  • Press OK to confirm.
  • The screen displays ANTIFREEZE.
  • Press OK to confirm.
  • Use the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21keys to set the desired antifreeze temperaturePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 30

To disable antifreeze temperature, go below+5.0 °C (41.0 °F).PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 31

USER MENU

  • Select item USER PASSWORD Set with the keysPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 and confirm with OK.
  • Use the keys PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21to enter 4 digits (dashes not included) between 0000 and 9999, and individually confirm them with «OK».PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 32

Password modification or cancellation

Press MENU for 3 secs., and enter the previously set password; follow the procedure described above to access the User PASSWORD SEtmenu:

  • set 4 hyphens (- – – -), the password will be canceled,
  • set another number and it will be modified

ACCESS TO THE CONFIGURATION MENU

From normal thermostat operation, access the menus by pressing and holding the «Menu» key.Select with the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21keys the CONFIGURE Set itemand confirm with OK: access the 1st item LANGUAGE SEt of the menu (see Chapter 8 the list of sub-menus to the item CONFIGURE).

CHANGESET LANGUAGE

  • When LANGUAGE SEt is displayed, press OK to confirm.
  • Use the keysPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 to select the desired language scrolling through available ones.
  • Confirm by pressing OK.

The selectable languages are: ITALIAN=It (default), ENGLISH=En, FRENCH=Fr, GERMAN=dE, SPANISH=ES.

  • Press the «back» key to exit.

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 33ACCESS TO CONFIGURATION MENU (installer)

TYPE TEMPERATURE ADJUSTMENT METHODS

  • The thermostat is factory set to work in THERMAL DIFFERENTIAL mode
  • ON/OFF with a preset thermal differential value (Hysteresis) of 0,3 °C.

Note: adjustable from 0,2 °C to 1,2 °C (from 0,3 °F to 2,1 °F).

  • The hysteresis value must be set according to the system’s thermal inertia; a low value is recommended for systems with radiators made of e.g. cast iron and a high value for systems with fan coils.
  • As opposed to the thermal differential, the temperature can be adjusted MODULATING PROPORTIONALLY (PROP) setting cycles from 7 to 20 minutes (default 10 minutes).
  • This system maintains the desired temperature more stable, whilst increasing the user’s comfort sensation and saving on energy consumption.
  • A long cycle is recommended for systems with high thermal inertia (cast iron radiators, floor systems) and a short cycle for systems with low thermal inertia (fan coils).PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 34

CHANGE UNIT OF MEASURE FOR TEMPERATURE READING

The thermostat is pre-set in the factory to display temperatures in degrees Centigrade (Celsius), it is possible to switch to the Fahrenheit scale or vice versa with the following procedure

  • Through the path CONFIGURE SEt ->selectUNIT SEt then pressOK.
  • Select the desired unit of measure with the keys: °C or °F, then press OK to confirm.
  • All temperature set points will be updated according to the new scale.
  • Press the back key to exit.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 35

CORRECTION OF ROOM TEMPERATURE READING
If for any reason the thermostat must be installed in a position where the measured room temperature might be affected (e.g. perimeter wall which is on average colder in winter and warmer in summer than the rest of the dwelling) the device has 2 separate parameters to adjust the room temperature measured in the Winter and Summer modes.

OFFSET for winter mode( )

  • It is the display that alternates the empty fields to be inserted (- – – -) with the current temperature value.
  • Use the key to enter positive values, and the key to enter negative values (sign «-»).
  • Possible correction -3.0 °C (-5.4 °F)÷3.0 °C (5.4 °F) default 0.0 °C/°F=- – – –
  • At each selection, the display will show the new correction value (e.g.: 0.6°C) alternated to the detected temperature value (e.g.: 21.2°C).
  • After performing the correction press «OK».
  • The display shows the OFFSET for the Summer mode ( ); proceed with the correction as per the above procedure or press back to quitPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 38

MAX AND MIN SET TEMPERATURE LOCK (Winter and Summer mode)
In certain thermostat installations (public buildings, hotels, etc.) it might be useful to limit the maximum and minimum temperature set points. This avoids incorrect settings by unauthorized personnel (energy savings). It is possible to limit (lock) the maximum, minimum, or both temperature values settable on the thermostat. The restriction may be applied either to the Winter or summer mode.

  • From normal thermostat operation, access the menus by pressing and holding the «Menu» key.
  • Through the path CONFIGURE SEt ->, select item LOCKS SEt. Press OK to confirm
  • In a sequential manner, it is possible to set maximum temperature locks (t1 comfort) and/or minimum (t2 economy) for the winter mode and/or maximum temperature (t1 comfort) and/or minimum (t2 economy) for the Summer mode.
  • If no locks have been entered yet, the display shows empty flashing fields (- – – -).
  • Use the keys to set the desired temperature lock values from time to time.
  • Upon completing each setting pressOKto confirm and move to the next lock item.
  • Press the OK impulse key to move to a different item. Press the back key to exit.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 43

General rule

  • If Set temperature t1 (comfort) is greater than the maximum entered lock, it will level out with it.
  • If Set temperature t or t2 is less than the minimum entered lock, it will level out with it.
  • The following rule will apply to all other temperatures: WINTER ( )=t1>t2>t – SUMMER ( )=t1<t2

PROBE MENU
In addition to the internal probe of the thermostat, it is possible to connect to terminals 6 and 7 «AUX 1» (see wiring diagrams in ch. 5.4) a supplementary probe (optional) which may be set to read temperature in various modes. Press for 3 secs. the key Menu, and through the path ->CONFIGUR SEt ->PROBE SEt, press OK to enter the menu. Selectable functions are as follows

Select the desired type of probe with the keys and confirm with OK.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 45

 

NO CONNECTION TO SEPARATE PROBE

Should you wish to disable the previously active separate temperature probe and go back to using the standard internal one (default), follow this procedure: key Menu down for 3 secs. and through path -> CONFIGURE SEt ->PROBE SEt ->select itemPROBE nO (NO) and press OK to confirm. Press the back key to exit.

  • Internal probe reading range: – 5.0°C ÷ +37.7°C (+ 23.0°F ÷ +99.9°F)PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 46

SETTING SEPARATE REMOTE PROBE

This is a remote probe to detect the temperature in a different room from the one where the thermostat is installed, for instance in the event of unfavorable installation or in premises unsuitable to reading and adjusting the temperature. The remote probe has the same parameters and reading range as the internal probe. Reading range: -5.0°C÷+37,7°C (+23°F÷+99,9°F). It completely replaces the internal thermostat probe and the product will control room temperature through this remote probe. After connecting the remote temperature probe to the thermostat, it may be activated through the path: Menu key for 3 secs. ->CONFIGUR Set ->PROBE SEt ->select itemREMOTE. Press «OK» to confirm. Press the back key to exitPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 47

SETTING FLOOR PROBE

This is a separate and remote controllable temperature probe, buried in the screed of an underfloor heating system with radiating panels, to monitor the temperature and turn off the system in case the temperature read exceeds a pre-set threshold value. After connecting the separate temperature probe to the thermostat, it may be activated by holding down the Menu key for 3 secs.->CONFIGUR SEt ->PROBE SEt ->select item FLOOR. Confirmwith the OK key.

  • Use thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 , keys to define the desired temperature threshold (e.g. 35°C) PressOK to confirm.
  • Press the PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21back key to exit.
  • Floor probe reading range: + 0.0°C ÷ +60.0°C (+ 32.0°F ÷ +140.0°F)PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 48

The thermostat displays and controls the room temperature detected by the internal probe:
at the same time the separate probe also detects the floor temperature, which will be compared with the threshold set by the installer, to prevent this temperature from exceeding the safety threshold. Should this occur the thermostat will switch off the system even if Set t temperature is not reached; the display signals this condition by displaying the code tP and the set threshold value flashes

SETTING SEPARATE EXTERNAL PROBE

This is an additional probe to read the temperature outside the dwelling (tE). It does not have any home temperature control features, which are controlled by the internal thermostat probe After connecting the  external temperature probe to the thermostat, it may be activated by pressing the Menu key for 3 secs. and through the path CONFIGUR SEt ->PROBE Set ->select itemEXTERNAL. Press «OK» to confirm. Press the back key to exit External probe reading range:: – 9.9°C ÷ +60.0°C (+14.2°F ÷+140.0°F).PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 49

CONNECTION TO EXTERNAL CONTACT FOR REMOTE THERMOSTAT SWITCHING ON/OFF

A remote device may be connected to the thermostat (e.g. telephone programmer, hourly switch, switch) able to remotely enable/disable the thermostat. From normal thermostat operation, access the menus by pressing and holding the key for 3 secs. «Menu» and through the path CONFIGUR SEt ->, select itemINPUT SEt. PressOKto confirm. Various operation modes may be selected depending on the type of contact free from potential (NO or NC) and type of device connected to the terminals 8 and 9 «AUX 2» (see par. 5.4 electrical connections  )

  • INPUT nO = Input exclusion (factory setting);
  • PHONE nC = for «Normally Closed» contact of a telephone Programmer;
  • PHONE nA = for «Normally Open» contact of a telephone Programmer;
  • DUTY nA = for «Normally Open» contact e.g.: switch;
  • DUTY nC = for «Normally Closed» contact e.g.: switch.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 50

ACTIVATION / DISABLING WITH A TELEPHONE PROGRAMMER
After connecting the Telephone programmer (optional) to the thermostat, it will be possible to select the nC (normally closed contact) or nA ( normally open contact «NO») contact type setting on the telephone programmer. Press the Menu key for 3 secs. and through the path, CONFIGURE SEt ->display item INPUT SEt, press «OK» and with keys choose item PHONE nC or PHONE nA. Press «OK» to confirm. Press the back key to exit.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 51

Example of remote thermostat switching on/off, connected to a telephone programmer with «nA» contact (NO normally open)PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 53

Programmer contact closure (change of state): causes temperature t1 COMFORT override and displaying associated symbols/setpoints and the steady icon “ ” indicating incoming telephone override. After that it will be possible to change the operation mode on the spot by manually acting on the thermostat keypad, even if the telephone programmer contact remains closed; the icon “ ” it will remain on (steady), indicating that the contact is still closed.

Programmer contact opening (change of state): causes operation status override OFF (par. 7.4 – Thermostat disabling)with antifreeze function unless it is disabled; the display shows OFF (steady) and icon “ ” flashing, indicating incoming telephone override. After that itwill be possible to go back to normal thermostat operation by pressing the key , the icon “ ” will go out indicating the end of telephone override.

«nA» DUTY – for normally open contact (NO)
By selecting this function it is possible to connect a NO remote contact which upon closing sets the thermostat in the OFF mode with antifreeze temperature t , unless it has been previously disabled. In this condition, it will not be possible to act on the thermostat keys to change the operation status. Open the contact and the thermostat resumes operation mode active before overriding. Press the Menu key for 3 secs., follow the path CONFIGUR SEt ->INPUT SEt ->select items DUTY. Press «OK» to confirm. Press the back key to exit.PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 54

«nC» DUTY – for normally closed contact (NC)
By selecting this function it is possible to connect an NC remote contact which upon opening sets the thermostat in the OFF mode with antifreeze temperature t , unless it has been previously disabled. In this condition itwill not be possible to act on the thermostat keys to change operation status. Close the contact and the thermostat resumes operation mode active before overriding. Press theMenu key for 3 secs., follow the path CONFIGURE SEt ->INPUT SEt ->select items DUTY. Press «OK» to confirm. Press the back key to exit the DESCALING CYCLE

  • If the function is activated, the programmable thermostat activates every day of the year (24h after the last intervention of the relay), for 2 minutes. It activates the controlled device (pump, valve, etc.) to prevent scaling or jamming caused by prolonged inactivity.
  • The thermostat activates only if the connected load was never switched on in the previous 24 hours.
  • From normal thermostat operation, press the Menu key for 3 secs., follow the path CONFIGURE SEt -> PUMP ON SEt -> press «OK» and with the keys select the desired item:
  • PUMP ON nO (NO) or PUMP ON 2′.
  • Press «OK» to confirm. Press the back key to exitPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 55

DISPLAY CONTRAST ADJUSTMENT
8 adjustment levels are available. Level 6 is set in the factory. From normal thermostat operation, press the Menu key for 3 secs., follow the path CONFIGURE SEt ->usePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys to select itemCONTRAST SEt. Press OK to confirm. Select the desired level with thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys. The contrast variation obtained will be visible at every selection. Press OK to confirm. Press the back key to exitPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 56

BACKLIGHTING
It lets you enable or disable timed display backlighting. From the normal operation of the thermostat press the Menu key for 3 secs., follow the path CONFIGUR SEt ->usePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys to select itemBACKLIGHTING Set.
Press OK to confirm. With the keysPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 select the desired item: timed backlighting 6 secs. or disabled backlighting nO (NO). Press OK to confirm. Press the back key to exit. Factory setting: timed backlighting 6 secs.

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 57

ENTERING AND MANAGING PASSWORDS
Some functions of the thermostat may be protected by a user Password (Ut) and/or an installer (Inst), so that they may be only modified by authorized persons. No password is active in factory settings.

ENTERING THE NEW PASSWORD

  • From normal thermostat operation, press theMenu key for 3 secs. and follow the path CONFIGUR Set ->PASSWORD SEt ->press «OK» to access the screen to create a secret User code (PASSWORD SEt Ut), confirm with OK, or select item PASSWORD SEt InSt with thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys and confirm with OK to create the Installer code.
  • Using thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys enter 4 digits (dashes not included) between 0000 and 9999, and individually confirm them with «OK».
  • Press the back key to exit The «User» password lets you access available functions through the Menu key.
  • If an installer password is also present the CONFIGUR SEt menu may not be accessed.
  • The «Installer» password lets you access all «Configurations» (CONFIGUR SEt) menu functions as well as User settings

PASSWORD MODIFICATION OR CANCELLATION 

When required, enter the previously created User or Installer password; follow the above procedure and access itemPASSWORD SEt Ut or InSt : – enter 4 hyphens (- – – -) to cancel the password – enter 4 new digits to modify the password

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 59

RESTORE (RESET)

  • The operation may be carried out by pressing the Menu key for 3 secs., following the path
  • CONFIGUR Set ->: using keysPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 select itemRESTORE SEt confirmwith OK.
  • The display will ask to choose between restore «YES» and «NO».
  • Use thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys, to select then press OK to confirm.
  • If you confirm YES «RESTORE» will be displayed for 3 seconds, then the system will restart and display the language screen.
  • Use thePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys to select the desired language scrolling through available ones.
  • Confirm by pressing OK. Press 2 times the back key to exit.
  • The thermostat enters normal operation.
  • Note: the thermostat restores many factory settings (default) with the exception of some special items that use the last set value (see summary table in chapter 2).

PERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 60

SYSTEM SOFTWARE INFORMATION

  • From normal thermostat operation, press for 3 secs. theMenu key and follow the path
  • CONFIGUR SEt ->, usePERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 21 keys to select item INFO SW to obtain information about the installed firmware.
  • Press the back key to return to the previous menu or press OK to exit the menuPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 61

POSSIBLE PROBLEMS AND SOLUTIONSPERRY- 1TP-TE028B- DIGITAL -THERMOSTAT - 62

DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT

  • When this symbol is found on the product or on its packaging, it indicates that this product cannot be disposed of as household waste.
  • It must be delivered to a specific collection point where electrical and electronic equipment is recycled, such as:
    • retail outlets, if a new product is bought, similar to that being disposed of
    • local collection points (waste collection centres, local recycling centres, etc).
  • By ensuring that the product is disposed of correctly, you will help prevent potential negative consequences for the environment and health, which can be caused by this product being disposed of inappropriately.
  • Recycling the materials will help conserve natural resources.
  • For more detailed information about recycling this product, please contact your Local Council, household waste disposal service or the shop where you purchased the product.

REFERENCE:

DOWNLOAD MANUALS:

PERRY 1TP-TE028B DIGITAL THERMOSTAT INSTRUCTION MANUALS

Perry-LOGO

PERRY 1TP-TE028B DIGITAL THERMOSTAT INSTRUCTION MANUALS

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)