Technical Data

  • Supply voltage: 230 V~ 50 ÷ 60 Hz
  • Type of action, disconnect and device: 1/ B / Electronic
  • Type of output: Relay with changeover contact NO / COM / NC voltage free – max 5(2)A / 250 V
  • Output connection (load): 2 or 3 conductors
  • Inputs for “Reduction” control, remote: for voltage free contact
  • Wire section at terminals: min. 0,75 mm ÷ max. 1,5 mm
  • Insulation type: Class II
  • Protection degree: IP30
  • Pollution: Normal
  • Operating temperature limits: 0 °C ÷ +50 °C
  • Storage temperature limits: -10 °C ÷ +65 °C
  • Temperature adjustment range: +5 °C ÷ +30 °C
  • Temperature display range: – 5 °C ÷ +39 °C
  • Reduction temperature: – 4 °C from the set temperature (”Winter” operation) +4 °C from the set temperature (”Summer” operation)
  • Precision of reading of the temperature: ± 0,5 °C
  • Ambient temperature indicator resolution: 0,1 °C
  • Differential operation: t selectable: 0,3 °C – 0,5 °C – 0,7 °C – 0,9 °C
  • Thermal gradient: 1 °K/15 min
  • Reference standard for CE mark: LVD EN60730-2-9
  • (directives 73/23/CEE – 89/336/CEE): EMC EN60730-2-9

SIGNALS AND CONTROLS

Temperature display

  • Room temperature display
  • Temperature setting display

The display normally shows the detected room temperature. When setting the temperature with the knob, the display shows the set temperature; a few seconds after the end of the operation the room temperature is shown again. In mode the set temperature shown is the reduced temperature: “Reduction” -4 °C from the Winter/ set temperature (for Summer model: -4 °C on “ ” and +4°C on “ ”). Winter Summer

Blinking signalsPERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT -  1

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT - 2

Operation mode switch (according to model)

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT 3

INSTALLATION GUIDELINES

Installation of thermostat: independent – fixed
Wall mounting

  • Install the thermostat at a height of 1,5 m ÷ 1,7 m from the floor, far from heat sources, air vents, doors or windows and anything else that could affect its operation.
  • Important: installation and electrical connections of devices and appliances must be carried out by skilled people and in compliance with current regulations.
  • The manufacturer declines any liability in connection with the use of products subject to special environmental and/or installation standards

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 4

FIXING BASE TO THE WALL

SWITCH MAINS SUPPLY OFF
Fix with screws the base of the thermostat to the back box (or to the wall), using the pairs of holes provided.

  • A- for round box (diam. 60mm) with claws
  • B- for round or square box (with screws)
  • C- for 3 spaces rectangular box (with screws)
  • D- knockouts allowing entry of wires (flexible only)PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 5

ELECTRICAL CONNECTIONS

SWITCH MAINS SUPPLY OFF

Connect 230 V power supply wires to the terminals

  • n° NEUTRAL
  • n° LINE

Connect the controlled device to the terminals:

  • n° common
  • n° normally open contact
  • n° normally closed contact

If you want to use remote selection of “ comfort” / “Reduction ” temperature, connect the exterior contact (potential-free – e.g.: from time switch) to the terminals and of the thermostatPERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 6

Remote selection of “Comfort” or “Reduction – ” temperature

Comfort ” temperature = Open contact
Reduction ” temperature = Closed contact
N.B control is operational within one minute.

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 7

Note for the contractor
Make the electrical connections taking particular care in the event of surface mounting without box that the wires are correctly arranged and do not hinder a proper fit between the body and the base.

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT 8

IN MULTIPLE INSTALLATIONS (offices, schools,houses)with a single, centralized “Reduction” control (es.: Time switch).

Thermostats supply voltage (230 V)

  • Connect NEUTRAL to all n° 6 terminals.
  • Connect LINE to all 7 n° terminals.

Inputs for “Reduction” control –

  • Connect terminals, ALL  A to the terminal of the remote contact.
  • Connect terminals, ALL  B to the terminal of the remote contactPERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 9

TEMPERATURE DIFFERENTIAL VALUE SETTING
The thermostat operates in differential modes (ONOFF) with a modifiable differential value (factory-set to 0,5 °C).

Changing the differential: position the dip-switches, located on the back of the thermostat, for the required differential value.PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT- 10

FIXING THE THERMOSTAT TO BASE

Fit the body to the base Exert light pressure until you hear the click of the attachment hooks. To remove the device insert a smal screwdriver as a lever in the position corresponding to the attachment hooks PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT 12

LIMITATION OF THE MAXIMUM ROOM TEMPERATURE

  • turn the knob to the 5 °C mark; then remove the knob
  • extract the JUMPER from its housing
  • Insert the JUMPER in the holes corresponding to the desired temperature
  • replace the knob, making certain it is positioned as before: 5 °C position coinciding with the index on the front of the case

PERRY -1TP TE410-B- ELECTRONIC -DIGITAL -THERMOSTAT13

REFERENCE:

DOWNLOAD MANUALS:

PERRY 1TP TE410-B ELECTRONIC DIGITAL THERMOSTAT User Manuals

Perry-LOGO

PERRY 1TP TE410-B ELECTRONIC DIGITAL THERMOSTAT User Manuals

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)